Tender For supply, installation and commisioning of iot based water level indicator system for lhb non ac indian railwaypassengercoaches(with 2 sensors)to rdso specification is/rdso-cg/0002-2025 or latest [ warranty period: 72 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, installation and commisioning of iot based water level indicator system for lhb ac indian railwaypassengercoaches(with 1 sensor)to rdso specification is/rdso-cg/0002-2025 or latest [ warranty period: 72 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For e-tender for rate contract for supply of lifesaving permanent implant product (item), for lifesaving cardiac operations and cardiac procedures (adult, paediatric & neonatal) i.e. coronary stent for u n mehta institute of cardiology and research centre (affiliated to b. j. medical college & nabh accredited) ahmedabad, gujarat, india. - bare metal stent - cobalt chromium, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, sirolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, sirolimus coated drug eluting stent with bioabsorbable polymer, 1, all sizes, sirolimus coated drug eluting stent with bioabsorbable polymer, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - sandwich stent design, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - single stent design, 1, diameter: 2.5 to 6 mm,length: 12 to 30 mm, coronary balloon mounted covered stent (monorail) - single stent design, 1, all sizes, sirolimus eluting bioresorbable vascular scaffold system, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, bare metal stent - cobalt chromium, 1, all sizes, sirolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, sirolimus coated drug eluting polymer-free coronary stent system, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - cobalt chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with durable polymer - platinum chromium, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, everolimus coated drug eluting stent with bioabsorbable polymer - platinum chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all sizes, zotarolimus coated drug eluting stent with durable polymer - platinum iridium/cobalt chromium base, 1, all s
Tender For supply, installation and commisioning of iot based water level indicator system for lhb non ac indian railwaypassengercoaches with overhead water tanks (with 2 sensors)to rdso specification is/rdso-cg/0002-2025 with corrigendum 1 or latest.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply, installation and commissioning of iot based water level indicator system for indian railwaypassengercoaches as per rdso specification no is/rdso-cg/0002:2025 with all latest corrigendum(01 set including qty. - (1.) 46 nos. provision of water level indicators for coaches with underslung water tank, (2.) 115 nos. provision of water level indicators for coaches with overhead water tank.) [ warranty period: 72 months after the date of delivery ] ]
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of thestent to a major government institute. unit:no [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply, installation and commissioning of iot based water level indicator system for overhead water tanks (with 2 sensors) for indian railwaypassengercoaches as per rdso specification is/rdso-cg/0002:2025 or latest. [ warranty period: 72 months after the date of delivery ]
Tender For srphc82281240-coronary drug eluting stents with (1) stent on cobalt chromium alloy or platinum chromium alloy. (2) stent with coating of polymer carrier for active drug ( sirolimus, everolimus or zotarolimus shown to be effective in preventing neo-intimal hyperplasia) (3) stent diameter should be from 2.5mm to 4mm and length of the stent should be 12mm to 48mm. (4) the strut thickness should be 91 micron or less. (5) stent delivery system should be monorail (single operator exchange or rapid exchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval shouldbe enclosed in the tender bid. (9) the long term efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals. (10) the documents related to the efficacy and safety of the stent should be only for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent toa major government institute.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For srphc82281215-coronary drug eluting stents (1) with single wire design with cobalt alloy shell and platinum iridium core (2) stent with coating of biolinx polymer carrier for active drug zotarolimus shown to be effective in preventing neo-intimal hyperplasia (3) stent diameter should be from 2 mm to 5mm and length of the stent from 8 mm to 38 mm. (4) the strut should be round with thickness ranging from 81 to 91 microns (5) stent delivery system should be monorail (single operator exchange or rapidexchange). (6) stent should be compatible with 5fr guiding catheter (7) stent design should be open cell type. (8) stent should be approved by dcgi. the copy of dcgi approval should be enclosed in the tender bid. (9) five years efficacy and safety of the stent in terms of target vessel revascularisation (tvr) and in-situ thrombosis (ist) should be documented / published in peer reviewed scientific journals.(10) the documents pertaining to the efficacy and safety of the stent should be enclosed for the brand that is offered in the tender bid (11) the manufacturer/supplier should submit proof of supply of the stent to a major government institute. ]