Get complete information related to latest Railway Point Clamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Railway Point Clamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Railway Point Clamp Tenders.
Tender For as per boq - drilling of gravel packed bore hole of 250mm diameter and lowering of liner assembly consisting of blind and strainer pipes of 125mm dia. upto 90 mtr by using direct/ rotary / dual rotary method including installation of mark-ii hand pump and construction of platform as per unicef norms / as per site conditions, providing of 125 mm dia. m.s. casing pipe. the 125mm dia. m.s. casing pipe isi marked should have thickness of 5.4mm conforming to as per is 4270 / 2001 medium class (part-i) 2004 (heavy c class) electric resistance welded beveled ended inside beed free pipes. all pipes from inside and outside to be provided with two coats of anti-corrosive paint of superior/approved quality. there should be no circumferential weld. the pipe from inside should be beed free having smooth finish. each pipe shall have subjected to hydraulic pressure test at the manufacturer works in accordance with is 4270/2001 with latest amendments. all the physical and chemical properties of pipe including tensile strength should be in accordance with is 4270/2001 with latest amendments., providing of pea shaped gravel as per is-4097 of 1967 with latest amendments for gravel packing of hand pump, shrouding during lowering of liner assembly, cost of slotting of ms pipe 125 mm dia ( to be charged as per actual), development of bore hole by air compressor of adequate capacity to give clear water free from sand and impurities, providing, fitting, installation, testing and commissioning of submersible pump set (reputed make) of suitable parameters depending upon the depth and discharge of the bore hole. the job includes erection of tripod stand and fixing of chain pulley block. then lowering of submersible pump set in to the bore hole by way of providing and lowering of 32 mm dia. hdpe pipe, submersible cable with fixtures such as rope, clamp, nuts, bolts & washers. fabrication and fitting of well cap. providing, fitting and installation of single-phase starter cum controller panel in sheet enclosure outdoor type conforming to is standard. providing and laying of 3 core submersible cable and 2-core pvc insulated copper conductor of suitable capacity as service line required from lt pole to starter panel of reputed make and fixing of lt control panel on wall by using wall mount fastners. making of electrical connections with the starter panel, service line and submersible pump set after properly thimbling and testing and commissioning thereof. the job includes the cost of material and labour charges. complete job.
Tender For supplying electrical materials and repair maintenance services for divabatti at awasari bk tal ambegaon dist pune - supplying and erecting modulartype switch6a/10a, supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length, providing cement concrete foundation including excavationfor the poles 60cm * 60cm * 1.5m deep in 1:3:6 cement concrete ( 20 * 25 mm stone metal) and 45cm * 45cm * 45cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 8.5 to 9 m poles) (16-3-2), supplying and erecting steel tubular swaged pole 139.7 * 114.3x 88.9 mm. dia with 4.5 * 3.65 * 3.25 mm thickness ( 4.5 + 1.75 +| 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation. (weight 101 kg.) as per specification no.oh-pl/stp, supplying and erecting street light bracket made from 25mm. dia bclass g.i. pipe, 0.6m. in, supplying and erecting led street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65, supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis, labour chrages for led fitting on street light or ms light pole., dismentaling charges -led street light of pole., 1.25 mm crca sheet metal enclosures box for timmer and mcb, supplying pvc insulated pvc round sheathed 1.5 sq.mm, supplying & laying armoured cable 4c x 6 sq.mm., supplying & laying armoured cable 4c x10 sq mm, supplying & laying armoured cable 2c x 10 sq mm, supplying & laying armoured cable 4c x 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting) 5-3-3, supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5-3-7, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching "on" & switching "off" street light as per daily sunset and sunrise respectively, supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete, supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete..., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3, supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole., supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1-4-3, supplying and erecting mains with isi mark wp2 x 2.5 sq mm.1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, 25 amp, 32 amp three phase l/t contactor, 2.5 sq. mm multistand copper wire, insulation tape, water proof tape, street light pole box frp, cement street light pole clamp, m.s. street light pole clamp, led street light arm bend pipe, small size frp box for mcb, big size frp box for mcb, supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below grou
Tender For 1)supply and erection of 40 nos of rcc poles and its clamp along with necessary fixing accessories. 2) supply and erection of 10 nos pscc pole its clamp along with necessary fixing accessories.3) supply and erection of 20 nos of guy set along with necessary fixing accessories.4) supply and erection of 02 nos of dp structures along with necessary fixin accessories.5) supply and erection of 02 nos of 400a single break gos along with necessary fixing accessories.6) supply and erection of 02 nos of dolo fuse cutout along with necessary fixing accessories.7) supply and stringing of 3 km rabbit acsr conductor. 8) supply and erection of polymeric type pin and strain insulators, pg clamps, ht supports, h frames, danger boards, road crossing guards etc., along with necessary fixing accessories. 9)necessary concrete work for pole base concreting, pole concreting, pole coping, guy concreting. 10) jungle clearance works wherever necessary.
Tender For quotation for supply of electrical items for psc pole shifting in gce keonjhar - supply & erection of psc pole with transportation, supply & erection of suspension clamp, supply & erection of lt ab cable, supply & erection of lt cable arm with clamp, frection of psc pole
Tender For 10/edc(s)/2025-26 - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 04 corners and 01 side for gate.
Tender For runningcontractfordepositworksunderedd-lambhua,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-baldirai,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted
Tender For runningcontractfordepositworksunderedd-jaisinghpur,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grou
Tender For runningcontractfordepositworksunderedd,sultanpur. - part-a (material), following materials supplied by the contractor :-, stone pad., lt clamp with nut & bolts., earth wire clamp with nut & bolts., clamp for top/t-off/dropper., suspension clamp., dead end clamp., eye hook., eye hook clamp., x-arm holding clamp., red oxide paint., alluminium paint., f-bracket., guarding angle., guarding angle clamp., shackle insulator., distribution box 3 phase with clamp., stay loop insulator, bolts, nuts & washers all sizes., l.t. connector (pearcing)., safe carriage/cartage of following items from store centre, sultanpur to work site including loading, unloading and proper stacking (distance within 0-50 km.), safe carriage of stp 11 mtr., safe carriage of pcc pole 8.5 mtr. long., safe carriage of acsr weasel conductor/dog conductor., safe carriage of 11 kv xlpe cable al. 3x120/3x70 sq.mm., safe carriage of lt xlpe cable abc 1 phase/3 phase., safe carriage of meter qubical., safe carriage of ct/pt combinud unit., safe carriage of t/f 25 kva., safe carriage of t/f 63 kva., safe carriage of t/f 100 kva., safe carriage of t/f 250 kva., safe carriage of t/f 400 kva., safe carriage of other line materials., dragging of stp from site to pit point., dragging of pcc pole from site to pit point., fabrication & errection of single pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole 11 mtr support on stp including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of single pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., fabrication & errection of double pole support on pcc pole including digging of pit & fixing of all accessories and clamps as per respo norms., grouting of structure by digging od pit 1.83 mtr. deep for 11 mtr stp/8.5 mtr pcc pole foundation is provided with help of steel or wooden formers, groutung with 1:4:5 ratio cement, sand & first class brick ballast 0.285 cu mtr for 11 mtr stp/8.5 mtr pcc pole plinthing 0.3 mtr above g/l and proper plastering as per respo norms., earthing of 11 mtr stp/8.5 mtr pcc pole as per respo norms., stay complete., laying stringing & sagging of new acsr weasel conductor/dog conductor including binding jumpering etc., digging of trench & laying of cable 11 kv xlpe cable 3x120/3x70 sq.mm including sands & brick., hanging hosting & clamping and g.i. pipe channel nut & bolts 3x120/3x70 sq mm xlpe 11 kv cable (cost of all accessories will be borne by contractor) as per resspo norms., installation and fixing of heat shrinkable type 11 kv cable joiting kit 3x120/3x70 sq mm xlpe cable box as per norms., high pressure testing after completion of laying of 11 kv xlpe cable, fixing of joints & termination. (testing equipment shall be arranged by the contractor)., making cable jointing kit i/d & o/d 3x120/3x70 sq.mm., installation of meter qubical., installation of ct/pt combinud unit., route cable marker with size 3x1.5 feet stone for underground cable at every 100 mtr from initial point with notice "11 kv u/g line" painted on it (all the material, manpower and t&p will be arranged by the contractor at his own cost)., road restoration charges for pucca road crossing., road restoration charges for footpath side., laying stringing & sagging of lt xlpe cable abc 3x120+1x95+1x16/3x50+1x35+1x16/1x25+ 1x16 sq.mm., erection and mounting of 25 kva t/f., erection and mounting of 63 kva t/f., erection and mounting of 100 kva t/f., providing and installation of smc box for 25 kva to 100 kva., installation of 250/400 kva t/f on plinth., construction of plinth for 250/400 kva t/f including of all material as per respo norms., fencing work suitable of 250/400 kva t/f plinth of size 15x12x8 and angles of suitable size should be grouted on all 0