Get complete information related to latest Rain Suit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rain Suit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rain Suit Tenders.
Tender For supply of 125 set rain coat with cap hood and separate water proof trouser with full sleeves made of superior quality polyster coated fabric with two pocket and heat sealing at allstitching joints to water penetration color-navy blue, grey, black, orange etc. make-duckback/versalis/wildcraft/rainbow/zeel & similar branded( size- m-50 set, l-50 set, xl-25 set) [ warranty period: 12 months after the date of delivery ] ]
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For tender for supply of erection and fabrication work - pan/quad bodies ki kamzor shell ko kaatkar hatana. 10/12 mm moti plate se taiyar kar yathasthan lagana. andar aur bahar se double coat welding kar leak/proof water/vacuum trial dena. , quad evam pan par lage vapour/steam line mein lage 600/1000 mm dia ke right/angle type vapour valves ko dismantle kar valve ki leak/proof marammat karna evam testing uparant punah yathasthan fit karna. , pan/quad ke vapour pipe ke gale/kamzor vapour pipe bends ko naye fabricate karke badalna 600 mm se 1100 mm dia. , quad evam pan ke vapour pipes. vapour/exhaust steam lines ko majbooti pradan karne ke liye angle iron athva plate se t/rings banakar support dena. , vapour cell. semi/kestner. pan va quad bodies ki purani gali steam jackets ko hatakar nikalna. 10/12 mm plate se naya banakar lagana tatha leak/proof trial dena. , pan. quad. vapour shell adi ka fin type cyclone fit karna. naya 8/10 mm plate se banakar fit karna tatha welding kar santoshjanak trial dena. , quad/pans par sthapit vibhinn steam ke gale/kamzor/leaky valves ko kaatkar/kholkar hatana tatha valve ki vanchhit marammat uparant nirdeshanusar fit karna. , air cooled/dry seed/vacuum/twin vertical crystallizer ki drive ke kshatigrast/ghise hue worm wheels ki gland housings ke bush badalne ke liye worm wheel evam worm shaft housings ko dismantle kar alag karna. gland housings mein naye gun metal bush lag jane par housings ki fitting uparant uplabdh karaye gaye worm wheel evam worm housings ko poorv ki bhanti fit kar alignment karna. , vacuum crystallizer ke shell ke gale/kamzor bhagon ko kaatkar hatana. nai/purani plate se shell modkar yathasthan fit karna. andar aur bahar se leak/proof welding karna tatha bahar se vanchhit strengthening karna. , air/water cooled/vacuum/twin vertical crystallizer ke kshatigrast danton wale worm evam worm wheel ko dismantle kar hatana evam unke sthan par naye worm evam worm wheel fit karna. reduction gear evam motor fit karke alignment karna evam trial dena. , pans/crystallizers par lage vibhinn gutters mein se kamzor gutters ko kaatkar hatana. purani plate se banakar lagana. , air/water cooled crystallizers ki purani/kamzor/tooti hui shaft ko dismantle karna. nai shaft taiyar kar yathasthan lagana evam samast arms lagakar santoshjanak trial dena. , air/water cooled crystallizers ki shaft ke gale/kamzor bhag ko kaatkar hatana. m.s. plate se shaft taiyar kar naye pipe ki shaft yathasthan fit karna evam samast arms poorv ki bhanti lagakar santoshjanak trial dena. , crystallizers ki drive shaft ke dono taraf dheele hue/ghise gun metal bush bearings ko nikalna. naye bush fit kar trial dena. , air/water cooled crystallizer ki shaft par lagi kamzor arms ko kaatkar hatana aur m.s. plate/pipe se nai arms fabricate karke shaft par lagakar sucharu trial dena. , air/water cooled crystallizer ke leaky/kamzor gate valve ko repair karke leak/proof fitting karna. , spray hetu sthapit mf 35x35 spray pumps ke elliptical suction pipes mein se gale/kamzor section pipes ko dismantle kar hatana. 8/10 mm moti m.s. plate se sample anusar may strainer fabricate kar yathasthan fit kar leak/proof trial dena. , quad/pans ke condenser mein lage multi/jet spray boxes ki vanchhit marammat karna. , spray pond ke main header. branch header evam branch lines ke gale/kamzor bhagon ko kaatkar nirdeshanusar nai evam purani plate se taiyar kar yathasthan fit kar leak/proof trial dena. , common injection header ke kamzor bhag ko kaatkar hatana. naya fabricate kar yathasthan erection kar leak/proof trial dena. , injection. spray pump ki drive motor ke gale/kamzor resistance box taiyar karna. sabhi internals fit karna. connection kar santoshjanak trial dena. , vertical spray pump ke gale/kamzor base frame ko dismantle karna. poorv ke anusar naya bed fabricate kar level karke yathasthan lagana evam pump fit kar alignment kar dena. , pans ke gale/kamzor feed distribution headers ko kaatkar hatana tatha unke sthan par nirdeshanusar m.s. plate
Tender For supply of glass wares, polythene wares and miscellaneous items at ssctpp, suratgarh- bottle polythene (pp) wide mouth with cap , burette , burette clamp mild steel chrome pla type with boss head, single pkt (ea , center to (300mmx). , pipette bulbs , pipette stand horizontal (12 pip , retort stand , side hole (225mmx , side hole (300mmx , silicone pipette bulbs , volumetric flask , (ii)beaker polythene capacity 1000 ml,pp autoclaveable , (iii) beaker polythene capacity 250ml,pp autoclaveable , (iii)beaker polythene capacity 500 ml,pp autoclaveable , , , beaker polythene pp auto clavable , blow in low density polythene 125 ml , blow in low density polythene 60 ml , chloroform bladder 500 ml , dropper sterile capacity 3ml , dropping bottle , latex bladder enkay no,5 with clip , measuring cylinder , wash bottle ldpe plastic , , , circular capsules fused silica without lid 48 x 15 (20 ml) , dishes culture petri , crucible fused silica for vm + lid 25x22x38 mm , beaker grifin, low form, with spout, graduated , burette - boroflo, screw thread with ptfe key , funnel plain 60° angle long stem glass 100 mm diameter , funnel separating pear shape with hollow plug stop cock, hollow interchangeable stopper, 500ml , measuring cylinder-single matric scale with pour out , pipette measuring (mohr type) accuracy as per class -a , volumetric flask with stopper , 50 ml burette with 1 ltr. reservoir , automatic zero burette accuracy as per class a with certificate , bod bottles with i/c stopper (300 ml) , bottles reagent amber with i/c stopper , bottles reagent plain narrow mouth with flat head i/c stopper , conical flask , flask boiling round bottom , gas burette with jacket cap. 100 ml (graduated burette 0-5 ml least count 0.1 ml for orset appratus) , orsat gas analyser (for analysis of flue gases) for determination of co2 o2 and estimation of co in flue gases complete with rubber tubing connector. 50 ml burrete and other accessories equipment shall be complete polished wooden cabinet equipment should be made of heavy walled borosilicate glass tube and stop cock , spares parts for orsat apparatus , tissue paper roll (double ply) (whatman) filter paper, circular catno. , cellulose nitrate filter 0,45 micron , , acid proof suit , , coal sample tray 12"x 14" big , , spatula (one end spoon and one end flat) 200 mm , , safety goggles (plain) , , direct reading % thermometer for caustic soda lye (45% to 50%) w/w with temperature correction , bottle relative density with capillary bore interchangeable tefflon stopper, 25ml , chlorine gas toner spanner , direct reading % thermometer for hydrochloric acid (27% to 32%) w/w with temperature correction , direct reading % thermometer for sulphuric acid (95% to 99%) w/w with temperature correction , heating element for muffle furnace (1200 degree c , kanthal a-1 resisative wire) , lab apron coat, free size , relay for muffle furnance , spare parts for muffle furnace (make jd refractories) m degree , test sieve for coal analysis, brass frame s.s./wire mesh (make-jayant) , test sieve sets for coal mill fines will be brass, 200mm dia 50mm height, wire cloth from one piece without seam (set shall be consist of three sieve lid & receiver) 50, 100 and 200 astm mesh (make-jayant) , thermal fuse , thermocouple cr/al for muffle furnace , water bath rectangular (double wall), ambient to temp. 95°c, +/-1°c, 220/230v ac, 12 holes 75mm dia (size 425*325*100mm) , water safety jacket(medium size) , temperature controller (pid with sgr power controller) , , working chamber of muffle furnance 6x6x12 inch , , laboratory hand gloves , , laboratory hand gloves (rubber acid and alkali proof) medium size , , laboratory hand gloves nitrile , , polythene sampling bags , , polythene sampling bags (size-1 kg) with zip , , polythene sampling bags (size-500 gm) with zip , , polythene sampling bags (size-250 gm) with zip , , crucible tong , , crucible tong 12" inch , , crucible tong 24" inch , , gooch crucible g4 (size-30 ml) , , vm
Tender For selection of local market rate for various items of work forpreparation of scheme estimate for implementation ofmgnrega & vbgramg schemes. --thermocol 12.5 mm thick., polythene sheet (150 gm per sqm)150 microns (or 0.15 mm), hire charges of concrete mixer 0.25 to 0.40 cum with hopper, hire charges of diesel road roller- 8 to 10 tonne, hire charge of shuttering plank (without prop )(25mm-30 mm) including all fittings ., hire charge of shuttering plank(with prop )(25mm-30 mm) including all fittings ., hire charge of shuttering plank( with prop (30mm 37 mm ) including all fittings ., hire charges of vibrator (needle type 40 mm), ms ornamental grill (above 10 kg/sq.m up to 16 kg/sq.m, nail (size1" to 2.5"), 1220. wire mesh (rabbit), glue (fevicol), 3050. galvanised steel corrugated sheets, 1023. galvanised steel j or l hooks 8 mm dia, galvanised steel bolts 10 mm dia and 7 cm long with nuts, g.i lime washere, bitumen washer, stainless steel bolts/ square bar and plates(size 5mm to 10mm), unslaked lime, supply of first aid box including medicines (specified by pia) at site., display board(ibs)(specification- as per amc including fitting & fixing), display board(community)(specification- as per amc including fitting & fixing), g.i. wire(weight 100 mtrs/. kg), coconut rope, sal ballah (10 cm ), sal ballah ( 125 mm ), sal ballah (15 cm ), cement primer(interior) normal, cement primer(exterior)water proof, primer( for wood), cement based dust putty, black japan paint, enamel paint for steel grill, synthetic enemel paint in black or chocolate shade., other local wood, supplying, fitting & fixing factory made p.v.c. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, pvc sheet miter, coloured orissa pattern w.c. pan 580x440 mm, vitreous china foot rests 250x125x25 mm, ptmt - towel rail (600 mm), fan hook, r.c.c. ventilator, vitrified floor tile 60x60 cm, turpentine oil, hydraulic door closer tuular type aluminium section body, anodiesd aluminium hanging type door stopper, vitreous china flat back wash basin 450x300 mm, r.c.c. pipes np2 class 450 mm dia, r.c.c. pipes np2 class 300 mm dia, red lead primer for steel grill, interior premium imulsion(plastic paint), exterior imulsion weather coat paint, distemper paint, supply of upvc pipes (b type) (for soil pipe purpose) & fittings conforming to is-13592-1992 (a) (i) single socketed 3 meter length (c) 160 mm, (ii) plain tee for soil pipe purpose. (c) 160 mm, v) plain y for soil pipe purpose. (c) 160 mm, supplying, fitting & fixing upvc down pipes a- type and fittings conforming tois:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (spun yarn, valamoid/bitumen/m-seal etc) complete. a) upvc pipes: (ii) 110 mm. dia., b) upvc fittings: a) plain tee (ii) 110 mm. dia., d) shoe (ii) 110 mm. dia, colour interlock c.c paver block ( 60 mm thick interlocking designer concrete paver block m-35 grade ), precast chequered cement tiles 22 mm thick dark shade using, precast chequered cement tiles 22 mm thick medium shade, upvcbend 87.50, 110 mm bend, upvc pipe clip 110 mm bend, check valve 32mm, check valve 40mm, bamboo 25 mm dia 2.5 meter long, bamboo ( 8 cm- 10 cm dia) including fixing, polyethylene water storage tank with cover and suitable locking arrangement ., supply of g. i. pipes of tata make including necessary sockets - 15 mm dia.(medium quality), supply of g. i. pipes of tata make including necessary sockets - 25 mm dia.(medium quality), chlorinated polyvinyl-chloride(cpvc) pipe 25mm outer dia., chlorinated polyvinyl-chloride(cpvc) pipe 15mm outer dia., 15 mm ptmt bib cock, ptmt push cock 15 mm dia, mirror of superior make glass 60x45 cm, flushing cistern p.v.c. 10 lts capacity (low level) (white) (withfittings, accessories and flush pipe), upvc pipes (w
Tender For providing, installation, testing and commissioning of electro-mechanical equipments at newly drilled t/well peerkho. - providing of 3 nos. submersible pump sets :- the job involves providing of 3 nos. submersible pump sets of specification 15000 gph x 80 m head of reputed make (one no. operational and two nos. standby) along with allied accessories to be installed in 10/12 inch dia. deep drilled new tube well peer kho. the job includes fabrication, providing and fitting of 2 no. clamps of span as per the required length to be fabricated and fitted with submersible pump sets with the help of heavy duty bolts and nuts (01 no. clamp to each pump set). the job also includes fabrication of 2 no. graded expander/ reducer for nrv of required size to be fabricated out of suitable thickness ms pipe threaded at one end and flanged at the other end. fitting of reducers/ expanders with 125 mm dia. column pipes at one end with flanged joint and with the discharge outlet of the submersible pumps at the other end.column pipes :- fabrication and providing of 125 mm dia. b class ms 20 nos. column pipes flanged on both ends. the length of each pipe shall be 3 mtrs. and shall be completely leak proof. the ms pipe shall be confirming to relevant isi specifications. the heavy duty flanges shall be furnished properly. one end of the flange shall be faced in such a way that a leak proof joint is made by providing and fitting a rubber sheet in between the two flanges and tightening it with nuts and bolts. each flange shall be provided with 6 no. equidistant holes of required dia. the job also includes welding of flat iron strips at each end for giving extra strength to the flanged joint and providing of 2 no. grooves on each flange on opposite sides for submersible cable to be accommodated though it. the welding of heavy duty flanges with the pipe should be carried out with superior quality pipe welding electrodes. then painting all the pipes with a coat of anti corrosive paint and two coats of super enamel paint. ms well cap, washout and riser pipe :- fabrication and fitting of ms well cap as per casing dia. of 8 mm thickness with one hole of approx 125 mm dia. in the centre and with holes/ cuts at an appropriate distance for passing submersible cable. providing and fitting of an arrangement for gi fitting near the discharge head outlet to provide water feeding to the gravel around the tube well casing. laying of delivery line for making of inter connections of top column pipe of new tube well by way of fabricating 900 ms bend out of 125 mm dia. ms pipe, welding of 2 no flanges one at each end. fabrication and fitting of 125 mm dia. ms pipe connection piece long as per site requirement with 90 degree bend with the help of nuts, bolts, washers, rubber sheet in between for leak proof joint. fitting of 1 no. 125 mm dia. heavy duty c.s. sluice valve through a connection piece as per site condition. fabrication, providing and fitting of 1 mm dia. heavy duty cast steel reflux valve. the sluice and reflux valve shall be confirming the isi standards and shall be of reputed make. fabrication and fitting of another 125 mm dia. connection piece flanged at both ends for working of washout by way of interconnecting delivery pipe through tee joint with the washout pipe.. fabrication and fitting of 1 no. blind flange at the end of washout. painting of exposed parts of the delivery line with two coats of anti rust primer and one coat of super enamel paint. the job also involves fabrication and fitting of one set of u-shaped clamps (for holding 125 mm dia. pipe) on the top column pipe for holding of column assembly on the casing and fabrication of 1 set of u- clamps to be used for extraction/ lowering of pump set along with column assembly. complete job includes cost of material, labour charges and carriage etc. and also making provision for wash out by providing and fitting of sluice valve of c.s of required capacity as per site conditions.lowering of submersible p