Get complete information related to latest Raising Main Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Raising Main Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Raising Main Laying Tenders.
Tender For laying and jointing of 200mmdia sewerage pipes of srinivas nagar colony near shivapuri colony under nagole section,sd-i,o and m divn-xi, (reserved for sc-category)
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc
Tender For macdamization of shutloo vohlutra main road by way of providing and laying of nallah muck, wbm g-ii,75 mm thick wmm,50 mm thick bituminous macadam, 25 mm thick semidense with 6 mm thick seal coat incl berm filling and p/l rcc pipes . (machine mix laid with paver)
Tender For a) laying of cc road with rmc and re-modelling of storm water drain with 600 mm dia. np3 class pipes from 9-1-224/11/a/11 to 9-1 333/f/8/1 and laying of cc road with rmc at 9-1-224/ a/13/1 b) laying of cc road with rmc from 9-1-224/1/ a/3 to 9-1-224/a/5 and re-modelling of storm water drain with 600 mm dia. np3 class pipes from 9-1-224/1/ a/3 to 9-1-224/a/1/16 near pindi girni c) laying of cc road with rmc from 9-1-224/ a/10 to 9-1-333/h/6/1, 9-1 333/h/6/1 to golden temple and re-modelling of storm water drain with 600 mm dia. np3 class pipes at 9-1-333/h/12 at laxmi nagar under langer house-66, karwan circle-13, kz, ghmc.
Tender For supply of sitc of 1.5 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 1.5 tr split ac , sitc of 2 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 2 tr split ac , supply and fixing of 25 mm dia u pvc plumbing drain pipes , sitc of 4 tr floor mounted tower ac , supply and filling of extra refrigerant gas non cfc r32 or r410a , supply and fixing of 32 mm nominal dia rigid upvc drain water piping , making provision of hole in wall rcc cc of 100 mm dia to 150 mm dia , supply of 4c x 2.5 sq mm pvc insulated pvc sheathed stranded copper cable , supply of 4c x 6 sq mm copper conductor power cable , supply of 4c x 25 sq mm copper conductor power cable , laying and fixing of cable , supply installation testing and commissioning 15.9 mm o.d. insulation 13 mm thick suction pipe , supply installation testing and commissioning 9.5 mm o.d. insulation 13 mm thick discharge pipe , supplying and fixing of 12 way double door vtpn mcb db , supplying and fixing 3 pole 32 a rating, 415 v, 10 ka mcb , sitc of 200a, 36ka, 4 pole mccb in the existing vtpn mcb db , providing, fabrication and fixing of approved color painted ms cage or ms mesh or ms jali , providing, fabrication and fixing of painted ms stand for outdoor unit
Tender For providing and laying of sn-8 upvc pipes of 315 mm o/d due to damaged existing sewer line, construction of manholes, construction of road gullies from house no hm 113 to sacha dhan gurudwara sahib, phase 3b1, s.a.s. nagar