Get complete information related to latest Rangefinder Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rangefinder Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rangefinder Repair Tenders.
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For procurement and installation of ece lab equipments - procurement and installation of ece lab equipments, single output variable dc rpsu single output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, dual output variable dc rpsudual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, function generatorfrequency range: 0.1 hz to 2 mhz.display: 4 to 6 digit led displayoutput waveforms: sine, triangle, square, pulse, ramp.amplitude: 0 20 vp-p.rise time: 100 ns.distortion: 1% (within acceptable range of frequencies).power supply: ac 220 v 10%, 50-60 hzoutput amplifier protection: protected against short circuit and 15v overload, digital storage oscilloscopebandwidth: 50 - 100 mhz.sampling rate: 1gs/s.channels: 2 (minimum)power supply: 100v 240v ac, 50-60 hzautomatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc.,horizontal scale: 5 ns/div 100 ns/div or equivalentvertical resolution: 8 bits (2 channels simultaneously)vertical sensitivity: 1 mv/div 10 v/div (at input)waveform math: +, -, x , , invert, fft etc.,waveform storage: 16 waveforms or equivalentcommunication interface: usb host, usb interface.7-inch color display or equivalentbasic trigger functions, digital vo;tmeterdc voltmeter digital 3 digit display (0-100 v), 0.5 % accuracy (class 0.5 equivalent) (2000), digital ammeterdc ammeter digital 3 digit display (0-2 a), 0.5 % accuracy (class 0.5 equivalent) (1500), eliminator transformer (stepdown)input - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, embedded lpc 2148 kit cpu - lpc2148, core - 16/32 bit arm7dmi-s speed - max 60 mhz, flash - 512kb, ram (on-chip) - 40kb, 46 general purpose i/opins, usb2.0 one 10bit a/d converter with 14 analog inputs, one 10bit d/a converter, six pwm &watchdog two uarts (16c550), two i2c (400kb/s), two spi s eight bit digital output, eight bit digital input, 16 x 2 characters lcd and 4x4 matrixkeypad one potentiometer for giving analog input, relay & buzzer interface i2c devices: rtc, eeprom and seven segment display, on board stepper motordriver lm35 temperature sensor, one rs 232 lines are terminated at 9 pin d type connectorand usb interface board has inbuilt power supply and mounted in sturdy cabinet accessories usb cable with utility software to download programs from pc to target board example programs in embedded c and assembly with documentation (soft copy) power chord, user manual with cd/dvd, free demonstration after delivery, single phase induction motorsingle phase induction motor, 230v ac, 50hz supply.power rating 1 hp (0.75 kw).speed 1440 rpm.capacitor start/run type suitable for lab useloading setup portable ammeter and digital tactometer contact type, single phase autotransformerinput - single-phase, 230v/240v, 50 hz, 4a, ac output - 0 to 270vac, class "h" or class f insulation., lvdt trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v /500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, strain guage trainer kitmetal foil strain gauge mounted on beam/cantileverstrain measurement under applied loadwheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltagezero and gain adjustment controlsprovision for applying calibrated loadsregulated power supply, 230 v ac, 50 hztable-top tr
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.
Tender For procurement and installation of eee lab equipments - procurement and installation of eee lab equipments, dc series motor with starting and loading arrangement with electrical work bench motor rating: 5 hp , 220 v , 1500 rpm, loading arrangement : mechanical rope with aluminum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s workbench: with back side lock 1. 2 point starter 2. ammeter ( 0 - 30a) dc 3. voltmeter ( 0- 300v) dc 4. rheostat - 1 no., single phase transformer step dwon, single phase, 2kva , 230/115 v , 4a / 8a, 3 phase transformer step down three phase, 2kva, 440/220v., transformer oil bdv test kit single phase, 230v, output voltage 60kv with timer, acidity test kit single phase, ac 230v,50hz, astm d974, rating scale, ,color chart, required, test tunes & solutions, three phase auto transformer three phase variac, 415 / (0-470)v, 15a, linear variable differential transformer measurement trainer input voltage : 230 v ac / 50 hz lcd display, digital voltmeterlvdt stroke length : 25mm potentiometer includedoperating temperature :10 c to 50 c, dso bandwidth: 50 mhz channels: 2 (dual trace)sampling rate: 1 gsa/s time base & voltage controls: variable display: color lcdprobes: 2 nos supplied interface: usb
Tender For supply of supply & installation of magnetic linear scales and dro in sk12 machine , supply & installation of magnetic linear scale and dro in l45 machine , supply & installation of magnetic linear scale in l45 machine
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For supply of mechanical engineering lab materials - mechanical engineering lab materials, serve motor drive kitinterface l293d motor driver ic with arduino to control direction of rotation of two dc motors), bldc motor kitbldc motor 1 nobldc motor drive -1noinbuilt volt and ammeter and rpm meterinbuilt power supplyinput 230v ac, lvdt trainer kit complete educational trainer for linear variable differential transformer (lvdt) displacement measurement. built-in ac excitation source and signal conditioning circuitry for lvdt operation. micrometer assembly for precise linear movement of the lvdt core. displacement range ~10 mm with clear front-panel adjustments for zero & calibration. digital display (typically 3 -digit) for direct readout of conditioned output/displacement values. test points and banana sockets for signal observation on external instruments. self-contained unit in a durable enclosure with labeled controls and educational layout. includes user manual and patch cords for experiments. operates on 230 v ac, 50 hz mains supply., multi-cylinder petrolphase : single phase load: mechanical load with ropenumber of cylinders : 4displacement : rope brakepower : 65hp,4000 rpm,1396 ccbrand material : mild steelengine type : 4 stroke self startfrequency : 15hzfuel consumption : petrolfuel tank capacity : 5 letermorh s test rig, tail stock assemblyheavy-duty lathe tailstock assembly for training; cast iron body with base, barrel (quill) ~50 75 mm stroke, hand wheel feed, dead centre mt2/mt3, set over screws for taper turning, spindle clamp, complete with all internal parts for dismantling and reassembly; suitable for 300 400 mm centre height training lathe., dc motorvoltage 220-440 v dcpower - 180 w speed - 200 rpm, hydraulic cylinderdouble acting hydraulic cylinder, bore 40 50 mm, stroke 200 300 mm, working pressure up to 100 160 bar, steel tube with honed bore, hard chromed piston rod, front & rear end caps, piston with seals and wear rings. supplied as standalone unit with suitable mounting for dismantling, inspection and reassembly., hydraulic opreated directional control valve (dcv)manually operated 3/2 or 4/2 way spool type hydraulic directional control valve, nominal size ng06 (cetop 3) or equivalent, rated pressure 210 bar, flow 20 40 lpm; valve body with hardened and ground spool, centering springs, ports p a b t clearly marked. supplied on small mounting plate for dismantling, inspection and assembly practice., bearing with shaft assemblyteaching unit with shaft 25 35 mm dia mounted in housing with deep groove ball bearings (6205 / 6206 class) at both ends; includes locking arrangements (circlips, lock nuts, covers). designed for repeated removal, cleaning, lubrication and refitting of bearings, with provision to mount on bench or test rig., coupling unit using driving and driven shaft plumber block bearing unit1. the plummer block housingmaterial: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing).sealing: felt seals or v-ring seals (to demonstrate lubrication retention).lubrication: provided with a grease nipple at the top center for manual lubrication practice.2. the bearingtype: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series).bore diameter: standard 25mm or 30 mm (ideal for lab scale).mounting: adapter sleeve mounting (h-series) to teach students how to lock a bearing onto a smooth shaft.3. shafting and couplingshaft material: ground carbon steel (en8 or en9) for high surface finish.coupling type: * flexible coupling: to demonstrate the bearings ability to handle slight misalignment.rigid flange coupling: to demonstrate traditional direct connection.driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven)., spring test machine load & displacement sensing load cel * capacity: 0 10 kno accuracy: 1% fs (better if 0.5% fs) displacement sensor * lvdt / digital encodero accur
Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)
Tender For purchase of equipments for eee department - 3 phase capacitor bank :* 3-phase capacitor bank * rating: 2 kvar * voltage: 440 v ac * frequency: 50 hz * heavy duty self-healing capacitor units * powder coated ms enclosure * compact panel mounted/floor mounted construction * proper ventilation arrangement to be provided * capacitor duty contactor/switch to be provided * fuse/mcb protection to be provided * discharge resistors to be provided for safety * proper earthing arrangement provided, 3 phase auto transformer starter :* 3-phase variable autotransformer * input: 415 v * output: 0 470 v ac (continuous) * current: 15 a * copper wound, carbon brush type * heavy duty toroidal/core construction * mounted in powder coated ms/crca enclosure * front panel mounted voltage control knob with scale indication * proper insulated terminals provided * floor/bench mounted type suitable for laboratory use * input/output terminal arrangement provided * mcb/fuse protection provided * proper earthing terminal provided * ventilation arrangement for heat dissipation, linear variable differential transformer measurement trainer :* input supply : 230 v ac, 50 hz * type : linear variable differential transformer (lvdt) trainer kit * lvdt stroke length : 25 mm * lcd display provided * digital voltmeter provided for output measurement * potentiometer provided for calibration and adjustment * signal conditioning circuit inbuilt * zero adjustment and calibration facility provided * test points provided for waveform/signal observation * clearly labeled circuit diagram on front panel * proper insulated terminals and safety sockets provided, plc trainer kit :* plc make :allen-bradley / delta electronics / siemens or equivalent* digital inputs : 8 20 nos.* digital outputs : 6 12 nos. (led / relay type indication)* communication port : rs232 / usb / ethernet (if available)* programming method : ladder logic programming* toggle switches for digital input simulation* led indicators for output status indication* analog potentiometers for analog input experiments* proximity sensor interface provided* relay output interface provided* input supply : 230 v ac, 50 hz* built-in regulated 24 v dc power supply* ladder diagram programming software to be provided* compatible programming software license to be provided* suitable for basic plc programming and automation experiments, conveyor arrangement with siren :* input supply : 12 v dc / 24 v dc / 230 v ac, 50 hz* control mode : manual / automatic operation using plc* conveyor arrangement with geared dc motor provided* proximity sensor provided for object detection* start and stop push buttons provided* audio siren indication provided* plc based control and sequencing operation provided* mini conveyor setup suitable for laboratory demonstration* geared dc motor driven conveyor mechanism* smooth belt movement with roller arrangement, digital storage oscilloscope (dso) :* bandwidth: 50 - 100 mhz. * sampling rate: 1gs/s. * channels: 2 (minimum) * power supply: 100v 240v ac, 50-60 hz * automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., * horizontal scale: 5 ns/div 50 s/div or equivalent * vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) * waveform math: +, -, x , , invert, fft etc., * waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. * 7-inch color display or equivalent * input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), on/off control of lamp using solid state relay kit:* type : solid state relay (ssr) trainer kit* control/input voltage : 12 v / 24 v dc or up to 30 v dc* output load voltage : 230 v ac, single phase* load control : on/off control of ac lamp load* solid state relay based switching circuit* opto-isolated input control* built-in ac lamp load* manual on/off switching arrangement* led indication for input and output statu