Get complete information related to latest Raw Water Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Raw Water Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Raw Water Pump Tenders.
Tender For supply of portable 0.5 hp barrel pump suitable for decantation/transfer of chemicals, def (diesel exhaust fluid), corrosive liquids, gasoline and similar industrial liquids, complete with lightweight portable motor, pump tube, flexible delivery hose, nozzle and power cable, capable of safe and efficient transfer operation from drums/barrels. pump body and wetted parts shall be made of corrosion resistant material such as ss/pp/pvdf suitable for chemical handling applications. operating voltage 220-240v ac, single phase, continuous duty, with minimum flow rate suitable for industrial liquid transfer applications. pump shall conform to is 9079 / is 5120 / iso 5199 / iso 2858 standards for centrifugal and chemical duty pumps along with applicable electrical safety standards. hsn code: 84138190. make: flux / lutz / finish thompson / groz / kti or equivalent. [ warranty period: 12 months after the date of delivery ] ]
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For supply of ammonia dosing pumps along with spares installed at 3x660mw, ktps. - chemical dosing pump, eccentric, guide pin, cross head, eccentric strap, slider.
Tender For repairing with replacement of worn out components, burn out winding of 2nos, 10hp capacity submersible pump motor sets at rawwaterpumping station under grww.
Tender For tender for supply of coupling key part no 01 for beacon weir secondary rawwaterpump , shaft nut part no 03 for beacon weir secondary rawwaterpump , o ring water thrower , part no 8 for beacon weir secondary rawwaterpump , lantern ring , part no 16 for beacon weir secondary rawwaterpump , distance piece , part no 18 for beacon weir secondary rawwaterpump , stuffing box bush part no 19 for beacon weir secondary rawwaterpump , impeller key part no 24 for beacon weir secondary rawwaterpump , pipes , part no 25 for beacon weir secondary rawwaterpump , coupling bush for beacon weir secondary rawwaterpump , coupling pin for beacon weir secondary rawwaterpump , shaft sleeve fam for beacon weir secondary rawwaterpump , gland plate for beacon weir secondary rawwaterpump , crw pumps jtc-33cl/1 stage pum for beacon weir secondary rawwaterpump , water thrower , part no 7 for beacon weir secondary rawwaterpump , grease nipple for beacon weir secondary rawwaterpump , bearing housing de part no 04 for beacon weir secondary rawwaterpump , bearing housing nde part no 12 for beacon weir secondary rawwaterpump , stud bolt with nut m12x80 part no 26 for beacon weir secondary rawwaterpump
Tender For rate analysis for removal of floating garbage and waste material from river at phase 1 to 4 intake channel and from pump bowl of ravet rawwaterpump house.
Tender For operation and maintenance work for 5 years for water supply system including all chemicals (alum, chlorine, lime, etc.) of nagar parishad baldevgarh. intake well with all civil, mechanical, eletrical work, rawwaterpumps, substation, starters,all ca