Get complete information related to latest Rcc Compound Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Compound Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Compound Wall Tenders.
Tender For procurement of electrical material for day to day repair and maintenance at various ctcs (community toilet complexes) and pts (public toilets) under south zone (for swachhta survekshan - 2025) - rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required.group c, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x1.5 sq. mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x2.5 sq. mm, supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. (a)5/6 amps switch, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 3 pin 5/6 a socket outlet, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 a socket outlet and 15/16 a piano type switch, connections, painting etc. as required., installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.upto 450 mm sweep, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole, supplying and fixing following rating ,double pole,240 volt,isolator in the existing mcb db complete with connections,testing and commissioning etc. as required.(b) 63 amps, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supplying, installation, testing & commissioning of led surface mountedbatten light of following body material and construction as per is : 10322with driver (replaceable) as per the requirement with driver efficiency>85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv withshort & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80,flicker free, (flicker should be below 5 %), life time (led,driver & electricalcircuitary), of minimum 50000 burning hours with , 70% of initiallumen maintained till life ends, cct 3000 k / 4000 k / 5700 k/6000 k/6500 k (as per ansi bin), sdcm(standard deviation colormatching) 3, maximum power consumption should not more than thespecified rating and fixture shall be of relevant bis standard and trademark certificate ( t.c.). manufactures word mark/ name engraved/embossing/ screen printing on housing. complete in all respect i/cconnections with 1.5 sq mm frls, pvc insulated copper conductorsingle core cable and earthing etc. as required with minimum 5 year oemwarranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80test report from nabl lab for all testing required for led fixtures asper bis shall be submitted. shape size and cct shall be as approved byengineer-in-charge as per requirement. (thermal management: heat sinkof aluminum housing such that led junction temperature shall not riseabove 90 c). 18- 22 watt, supply,installation,testing and commissioning of single /three phase monoblock pumpset complete with all accessories workable on 240/
Tender For corrigendum : augmented opto electronic repair facility along the existing infrastructure of gce lab - aluminum paneled structure , false ceiling alongwith supporting structure , wall mounted fan with wiring , surface lights with wiring , exhaust fan with wiring
Tender For repair/renovation of washed stone grit plaster on exterior wall surface at various places of main hospital skims, maternity hospital,hostels, facultyquarters, sarai ist 2nd, staff quarters and other, required damaged places etc at skims soura.
Tender For corrigendum : repair and renovation works including external painting to the wall surface and gutters of bl-2 and bl-3 shops inside factory of engine division.
Tender For external finishing work with change of colour scheme including repair work of the surface wall at d.a. flats, nimri colony, ashok vihar, delhi.
Tender For providing foundation for rcccompoundwall, yard road and brick work gi angle barbed wire and allied civil works etc., for proposed extension of new eht supply with dual source of supply for a demand of 90 mva at 230 kv level to m/s. cmwssb, 400 mld desalination plant, nemmeli village, thiruporurtaluk, chengalpattu district on dcw basis.
Tender For under case number 11/25x3/5, small construction work, maintenance, repair, patchwork and material supply work in ward number 09 under the body area.-, , cement concrete grade m-10 (nominal mix with 40 mm maximum size of stone aggregate-providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level, foundations, footings, bases of columns, etc. for mass concrete centering and shuttering including strutting, propping stretchin g etc. complete for and removal of form work by sheet plate or ply wood shuttering for:, cement concrete grade m-20 (nominal mix) with 20 mm maximum size of stone aggregate-providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level, providing and laying cement concrete grade m-20 (nominal mix 1:1.5:3) with 20 mm graded crushed stone aggregate, mixing shall be in mechanical mixer, laying with paver compacting by use of pin, plate/screed vibrators including form work by strong steel girders fixed by spikes, separation membrane 125 micron thick, i/c cutting of joints @ 4 to 5 m interval & filling it with hot applied bitum inous sealant (without dowel bars). (max. thickness 20cm)", , thermo-mechanically treated bars. (fe 500 d or more)-"reinforcement for r.c.c. work including straightening, cutting, bending, placi ng in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/inclined pos ition of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of is: 13920; is 456 & sp: 34) etc. complete.", construction of granular sub-base by providing coarse graded material (cbr>30), spreading in uniform layers with motor grader on pr epared surface, mixing by mix in place method at omc and compacting with vibratory roller of 80-100 kn static weight to achieve the desired density, complete in all respect as per relevant clauses of section-400.", structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, , two or more coats on new work.-"distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.", 300 mm dia-"providing, laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing of joints., 450 mm dia-"providing, laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing of joints, 600 mm dia-"providing, laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing of joints., ,
Tender For under case number 04/25x3/5, small construction work, maintenance, repair, patchwork and material supply work in ward number 02 within the body area.-, , cement concrete grade m-10 (nominal mix with 40 mm maximum siz of stone aggregate-providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work u to plinth level., , foundations, footings, bases of columns, etc. for mass concrete."-"centering and shuttering including strutting, propping stretchin g etc. complete for and removal of form work by sheet plate or ply wood shuttering for:", , cement concrete grade m-20 (nominal mix with 20 mm maximum size of stone aggregate-providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level., , providing and laying cement concrete grade m-20 (nominal mix 1:1.5:3) with 20 mm graded crushed stone aggregate, mixing shall be in mechanical mixer, laying with paver compacting by use of pin, plate/screed vibrators including form work by strong steel girders fixed by spikes, separation membrane 125 micron thick, i/c cutting of joints @ 4 to 5 m interval & filling it with hot applied bitum inous sealant (without dowel bars). (max. thickness 20cm)", , thermo-mechanically treated bars. (fe 500 d or more)-"reinforcement for r.c.c. work including straightening, cutting, bending, placi ng in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of is: 13920; is 456 & sp: 34) etc. complete.", , construction of granular sub-base by providing coarse graded material (cbr>30), spreading in uniform layers with motor grader on pr epared surface, mixing by mix in place method at omc and compacting with vibratory roller of 80-100 kn static weight to achieve the desired density, complete in all respect as per relevant clauses of section-400.", , structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete", , two or new work.-"distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.", , 300 mm dia-"providing, laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing o f joints.", , 450 mm dia-"providing, laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing o f joints.", , 600 mm dia-"providing. laying and jointing non-pressure (np4) rcc socket & spigot pipes with rubber gasket joint including testing o f joints.",