Web Analytics Made Easy - StatCounter

Rcc Pole Repair Tenders

Get complete information related to latest Rcc Pole Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Pole Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Pole Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45246681 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For corrigendum : supply of variousitems to - customised precast rcc product as per specific drawings and design provided by indenting depatment including different grades of concrete,reinforcement and centering and shuttering ,curing etc,complete items as per below mentioned grade

CTN :45349762 Due date: 09 Jun, 202609 Jun, 2026 2.95 Lacs
Tender For procurement of materials for repair of various components used in the fixing of light poles installed across of the failure different wards within municipal area - 61.13 p/l of double wall corrugated hdpe pipe confirming to is 16205 p-24, stiffness class 750 n, externally corrugated and having smooth surface inside with hdpe coupler, elbow, tee at required depth below the ground for laying cable of following nominal outer dia. mfr test report from nabl accrediated is to be submitted. (excavation of earth & back filling with compaction is to be paid extra) all as per pre approved by engineer in-charge.. for additional technical parameters of products/ work, refer annexure "a" attached with this bsr 50mm dia. , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured copper cable confirming to is:1554 p-i / is:7098 p -i of 1.1 kv with electrolytic grade copper made of copper rods confirming to is 613-1964, of purity >99.7%, inner/outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure 'a' attached with this bsr 3 core , supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943-1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring, compression nut, heavy duty aluminium lugs (as per is 8309-1993) duly crimped with crimping tool, pvc tape as per is 8337-1976 of following size of pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr 4 x 10.0 sq.mm pvc tape roll , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discom's specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure "a' attached with this bsr type a lt connector for aerial bunched cable each 73.00

CTN :44808034 Due date: 20 Apr, 202620 Apr, 2026 15.00 Lacs
Tender For work of providing electrical repairing material for led lights installed in the municipal area. - providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un-arrmoured aluminium cable confirming to is:1554 p-i/is:7098 p-1 of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6%, inner / outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench / cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure 'a' attached with this bsr 1 6x 2 sq. mm. (insulated) , providing & fixing of 240/415 v ac mcb with positive isolation ka breaking capacity (b/c/d tripping characteristic as load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996)/conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl/cpri / erda accrediated lab type test reports & all as per pre approved by engineer in 0.5 a to 5 a ratin , double pole mcb(with b/c curve tripping characteristics) , four pole mcb (with b/c curve tripping characteristics) , supplying and fixing of aluminium (iec 60105 iso 209-1,2) / copper (iec 60028) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr. , main panel street light control panel commissioning kiosk type weathe proof panel out door main cubic panel size 750x1250x500 they shall be in two section comaring as follows bsr 2017 (59.57) , supply & drawing wiring for sub mains isi marked (is:694) 110volts grade pvc insulated flat twin core sheathed solid aluminium 4 sq mm 2 core flat

Central Government/Public Sector

CTN :44597031 Due date: 02 Apr, 202602 Apr, 2026 NA
Tender For supply of 100000000000 cleaning of 500 liter cap. pvc tank refer atc document , 100000000001 cleaning of 1000 liter cap. pvc tan refer atc document , 100000000002 cleaning of 2000 liter cap. pvc tank refer atc document , 100000000003 cleaning of 3000 liter cap. pvc tank refer atc document , 100000000004 cleaning of 5000 liter cap. pvc tank refer atc document , 100000000005 cleaning of 10000 liter cap. pvc tank refer atc document , 100000000006 cleaning of service water rcc tank refer atc document , 100000000007 cleaning of drinking water rcc tank refer atc document , 100000000008 cleaning of ro product water rcc tank refer atc document , 100000000009 cleaning of fire station water rcc tank refer atc document , 100000000010 cleaning of raw water rcc tank refer atc document , 100000000011 cleaning of indus waste water rcc tank1 refer atc document , 100000000012 cleaning of indus waste water rcc tank2 refer atc document , 100000000013 cleaning of indus waste water rcc tank3 refer atc document , 100000000014 cleaning of rain test site-01 water rcc refer atc document , 100000000015 cleaning of rain test site-02 water rcc refer atc document , 100000000016 cleaning of canteen-01 food waste sump r refer atc document , 100000000017 cleaning of canteen-02 food waste sump r refer atc document
 Loading, Please wait...

Connect us via What's Up