Get complete information related to latest Rcc Step Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Step Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Step Tenders.
Tender For corrigendum : provision of soiling and gsb , provn of rrm retaining wall , provn of 600 mm dia rcc hune pipe culvert with pcc block masonry , provn of rcc culverts for constr of op track , provn of 2 x 800 mtr crash barrier , provn of gccms drainage along road , provn of constr of 1500 mtr pcc block wall drainage , provn of geo cell membrane , hiring of labour
Tender For supplying all labour, material and t&p for laying of pipe lines, supplying & fiting of sluice valves, construction of valve chamber, providing fhtc in connection with pws to tumbagada, andanda & sapuakhata under patrapur block. - annexure - a, laying of pipe lines, fiting of sluice valves construction of valve chamber providing fhtc in connection with pws to tumbagada, supplying all labour and t&p for earth work in all kinds of soil within 50 m initial lead and 1.5 m initial lift including rough dressing and leveling etc., in foundation and plinth as per direction of engineer in-charge., supplying all material, labour , t&p for laying of following od hdpepipes conforming to is 4984-2016 and specials of the following outside diameter and class-4 to class-5 and jointing by fusion welding method including testing etc. all complete as per direction of engineer-in-charge, 160mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, 110mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, 90mm dia o.d. hdpe. pipe (including pipe cost) pe100, pn-06, supplying all labour, t&p for filling in pipe line trenches with excavated materials including watering etc., all complete including proper care to the laid pipe lines to prevent damages of pipes and specials as per the direction of engineer-in-charge., supplying all labour, materials, and t&p for drilling perfectly horizontal bore of required dia so as to accommodate following size hdpe. pipe line into the hole including inserting the pipe with out disrupting the traffic or cutting road including jointing with water main pipe lines etc, (excluding cost of pvc pipe) and as per the direction of engineer-in-charge, 160 mm dia hdpe pipe, supplying all labour and t&p for cutting cement concrete road for taking pipe line etc., complete and as per direction of engineer-in-charge., supplying all materials, labour t&p for making good to the damages of cutting of cement concrete road for taking pipe line and with 40 mm size crusher broken metal concrete etc., cc (1:4:8) of thickness 0.10 mtr and top 12 mm size crusher broken chip;s concrete cc(1:2:4) of thickness 0.075 mtrs including all cost, conveyance, royality of materials including watering, curing and ramming etc., all complete and as per specification and direction of engineer-in-charge, supplying all materials, labour and t&p for fixing of following sizes of c.i. sluice / non return valves with double flanged ends for water works purpose for following nominal diameter including cost of nuts and bolts, rubber insertion as per specification etc., complete., 150 mm dia c.i s.v, 150 mm dia c.i n.r.v, 100 mm dia c.i s.v, 80 mm dia c.i s.v, supplying all materials, labour and t&p for fixing of 15mm to 25 mm dia single air valve including fitting of required pvc service saddle for water works purpose for following diameter, including drilling the water main as per specification etc., complete., supplying all materials, labour, t&p for construction of brick masonry sluice valve and non return valve chambers of internal size 90x90x120cm with all lead royalty etc. such as earth work excavation, bed concrete with c.c. (1:4:8), kb brick in c.m. (1:6), 12mm cement plaster with c.m. (1:4), rcc cover slab with cc 1:2:4 etc., and as per approved p.h. drawing and design etc., complete and direction of engineer-in-charge., supplying all materials, labour and t&p for fabricating, fitting and fixing with specials at the required site using hot dip galvanized pipes of medium class and standard weight of reputed make (tata / zindal make) confirming to is 1239(p.1)2004/is:1161 of the following dia including cutting the pipes and flanges drilling the bolt holes matching the pipes flanges and jointing with proper gradient and alignment, welding with using electrodes, fitting, fixing using mobile diesel generator set etc., complete as per direction of engineer-in-charge to be used to cross drainage work incl
Tender For renovation works and extension works - earthwork, pcc, rr, rcc, solid block masonry, painting work, electrical and plumbing works, computer networking and telephone cabling works.
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and