Get complete information related to latest Reading Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reading Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reading Light Tenders.
Tender For corrigendum : supply of equipment for solar pv and wind power c c - dc voltmeter analog type_0-50v , dc ammeter analog type_ 0-2a , solar cell , light source made from 20 leds , constant current source for turning on the led , measurement of light emitted by led , controller for selecting the led recording short-circuit current , dc volt meter analog type 0-100 , dc ammeter analog type_0-5a , connecting wires , light source halogen lamps , 3. 5 digit, digital voltmeter , potentiometers 0-10ohm , potentiometers 0-100ohm , 3. 5 digit, digital ammeter , jumper wires , solar inverter , solar battery , filament bulb load , pv module of 500watt , 1000w solar panel for ac, dc load , mainframe , 1. 5kw hybrid pq_dq axis grid synchronized 1or3 phase inverter , temperature indicator and controller
Tender For supply of ahuja mike 495v2 , earphone for sanchar communication , steel display frame for information of training equipment , cable for welding set , steel training table of 4 ft x 2 ft for ops room , steel training table of 12 inch x 18 inch for ops room , pa speaker ahuja 6w , pa speaker ahuja 30w , emergency light wipro , grid board arcylic , change over switch 100 amp , gps tracker , drone training opticals , safety suit for firing , drone training display wooden board 4 ft x 3 ft , fabricated fpv drone , anti drone protection net 50 ft x 60 ft
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer- the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.warranty must be one year., electronic balance- the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. warranty must be one year., vaccum pump - the pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted withvacuum and filter cartridge., hot air oven- the inner chamber should be made of stainlesssteel and the outer chamber should be m.s powdercoated. the maximum capacity of the oven shouldbe 100 ml or more. the operational temperatureshould be between ambient to 250oc or more witha temperature accuracy of 1o c. pid based digitaltemperature control., double distillation unit- the unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil bath- the oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240oc (0.1oc increment) with a temperature stability of 1oc, water bath- the water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars., ph/ condutivity meter - operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range shouldbe in between 0.00 to 29.99 s/cm, uv cabinet- operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometer- application: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca 2+ :0-99.9 ppmli 2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required
Tender For corrigendum : tender for supply of laboratory equipments andinstruments - machinery & equipment, hplc module pump(quaternary gradient) high precision dual plunger design. system designed to work in micro , semi-micro analytical to semi prep scale high speed double micro plunger in parallel pump with automatic pulsation correction mechanism achieving pulse free solvent delivery forced check valve designed for excellent solvent delivery control flow raterange:0.0001ml to 10.0ml/min each pump flow rate resolution of 3nl/step increment built in self diagnostic, auto purge function flow precision is less than 0.06% rsd flow rate accuracy: 1% concentration accuracy 0.5%washing kitgradient mixer,reservoir trayquaternary gradient unitdgu-20a5r bkl degassing unitmanual injector: rheodyne injector with 20 ul loop & mounting plate 25ul hamilton syringepda detectorwavelength 190 800 nm, channel 512, drift smaller than 0.5x10-3 au/hour, noise smaller than 0.6x10-5 au. wavelength accuracy should be 1 nm, linearity: 2.0au or more. a deuterium lamp [d2] and a tungsten lamp [w] should be available as light source a conventional hplc flow cell [12 l volume, 10 mm cell path length]. lamp replacement: front access, lamp life time : 2000 hours (d2 lamp)controller alite system controller, solvent bottles with cap 5/pkt, chromatographic software
Tender For touch switch readinglights for luggage rack for t-18 as per icf drg. no. ts/dtc-6-2-002 item no. 13 note-supplier should be provided sample to consignee for approval before supply.