Web Analytics Made Easy - StatCounter

Real Time Data Transmission Tenders

Get complete information related to latest Real Time Data Transmission Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Real Time Data Transmission Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Real Time Data Transmission Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45118917 Due date: 30 May, 202630 May, 2026 NA
Tender For supply of weidmuller make remote io fieldbus coupler having model no. ur20-fbc-mod-tcp-v2 and part no. 2476450000 , weidmuller make remote digital input module having model no. ur20-16di-p and part no. 1315200000 , weidmuller make remote digital output module having model no. ur20-16do-p and part no. 1315250000 , weidmuller make fast ethernet 5 port network switch having model no. ie-sw-blb-05-5tx and part no. 2908030000 , weidmuller make fast ethernet 8 port network switch having model no. ie-sw-blb-08-8tx and part no. 2908040000 , weidmuller make wi-fi client having model no. ie-wl-bl-ap-cl-eu and part no. 2536600000 , weidmuller make modbus tcp or rtu protocol gateway having model no. ie-cs-mbw-2tx-1 com and part no. 2682600000 , weidmuller make antenna cable having model no. ie-cc-nm-rpsmam-5m and part no. 2788060000 , weidmuller make ups control unit having model no. cp dc ups 24v 20a or 10a and part no. 1370050010 , weidmuller make 24v, 7.2 ah battery having model no. dura eco la- bat 24v and part no. 2789910000 ) /bid number : gem/2026/b/7505125 * /dated: 08-05-2026 & & / bid document 1 / 14

CTN :45088867 Due date: 22 May, 202622 May, 2026 NA
Tender For supply of modbus tcp rtu gateway (q4)

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

CTN :44647115 Due date: 30 Mar, 202630 Mar, 2026 NA
Tender For calling a budgetary offers for supply, installation and commissioning of remote scada scheme at various substations under pune circle-1 2 scada/sas software package includes sas runtime & editor software, log sheet, event sheet, trend sheet generation software, metering gateway runtime & editor software, os windows 10 & above, microsoft excel etc. for one server pc. the software shall support iec 61850, iec 104, iec 101 & modbus protocol. number scada / sas tag licence 1500 nos. tags scada/ sas software package includes sas runtime & editor software, log sheet, event sheet, trend sheet generation software, metering gateway runtime & editor software, os windows 10 & above, microsoft excel etc. for one server pc. the software shall support iec 61850, iec 104, iec 101 & modbus protocol. 10 set 1 set number scada/sas tag licence 4500 nos. tags frtu with bi & bo, gateway / protocol converter/ rtu along with runtime & editor software having following drivers 1. iec 61850 master & slave 2. iec 101 master & slave 3 3. iec 104 master & slave 13 no. 4. rs 485 modbus master & slave. lan ports 04 nos. rs 485 ports 02 nos, rs 232 ports 02 nos. binary inputs :- 48 nos. (for @ 02 to 03 bays) binary outputs:- 24 nos. ((for @ 02 to 03 bays) 4-20 ma analog inputs card (min 08 nos. of inputs) gateway /protocol converter / rtu along with runtime & editor software having following drivers 1. iec 61850 master & slave 4 2. iec 101 master & slave 3. iec 104 master & slave 12 no. 4. rs 485 modbus master & slave. lan ports 04 nos. rs 485 ports 02 nos. 5 6 ied compliant for iec 61850 protocol having (optional if frtu with bi & bo cards used then ied not required) except bridgestone ss minimum 48 number of binary inputs minimum 24 number of binary outputs communication port for iec 61850 protocol. metering gateway for configuration & integration of mfm meters with minimum 04 nos. of rs 485 ports or 04 nos. of modbus tcp ip ports & 02 nos. of rj45 lan ports. at least communicate 32 mfm meters to single ports. (optional) 13 no. 12 no. 7 1 kva ups along with maintenance free battery having backup of minimum 5 hours. 13 no. 8 19 core, 1.5 sqmm armoured copper cable 500 mtr 9 16 port unmanaged ethernet switch (2 fo ports + 14 lan ports) 13 no. 10 08 port unmanaged ethernet switch (2 fo ports +06 lan ports) 13 no. 11 16 port unmanaged ethernet switch (14 fo ports + 02 lan ports) 7 no. 12 06 core liu 6 nos.
 Loading, Please wait...

Connect us via What's Up