Web Analytics Made Easy - StatCounter

Rechargeable Batteries Tenders

Get complete information related to latest Rechargeable Batteries Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rechargeable Batteries Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rechargeable Batteries Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45727126 Due date: 29 Jul, 202629 Jul, 2026 NA
Tender For supply of low maintenance lead acid stationary secondary cell2v 300 ah. with low maintenance lead acid stationary secondary cell 2v 300ah with hard rubber/pp-cp container with accessories inter cell connectors , nuts ,bolts and washers,micro porous ceramic vent plug in dry and uncharged condition confirming to rdso specification irs-s-88/2004 with latest amendments. [ warranty period: 48 months after the date of delivery ] ]

CTN :45514433 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras supply of 48v - lithium-ion rechargeable batteries for e-rickshaws (v2) (q3)

CTN :45650786 Due date: 02 Jul, 202602 Jul, 2026 1.00 Lacs
Tender For supply of navigation and tracking system , remote control for soccer drone , rechargeable batteries for soccer drone , storage media for drone navigation data , projector stand for media display

Central Government/Public Sector

CTN :45665004 Due date: 23 Jul, 202623 Jul, 2026 NA
Tender For supply and configuration of digital trans-receiver handheld 5 watt vhf set conforming to clause 5b of rdso specification no. rdso/spn/tc/107/2018 ver, 2.0 or later, along with two set of oem approved rechargeable batteries including one as spare, additional requirements: 1) warranty :- warranty for radios and rapid chargers shall be at least 5 years and warranty for battery packs shall be for at least 1 year. material should be mtcte approved or certification may be given by the participant that valid mtcte certificate will be presented before commencement of deliveries. [ warranty period: 60 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45602156 Due date: 29 Jun, 202629 Jun, 2026 3.14 Lacs
Tender For supply of supply, testing and acceptance of hand held metal detector. , supply of compatible 9v rechargeable batteries of suitable capacity for hhmd. , supply of external battery charger suitable for charging 9v rechargeable batteries for hhmd. , supply of cleaning kit for maintenance and upkeep of hhmd. , supply of sensitivity adjustment tool compatible with hhmd.

CTN :45601997 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply of unbranded electrocardiograph 12 channel ecg page writer machine direct writing with electronic leads rechargeable batteries with complete accessories , unbranded multipara vitals monitor high end , unbranded distant vision testing drum , unbranded puls oximeter , unbranded cervical collar adjustable , unbranded manual bp apparatus mercury led

Central Government / Public Sector

CTN :45547385 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : supply of low maintenance lead acid stationary secondary cell 2v 200ah with hard rubber container with accessories inter cell connectors , nuts ,bolts and washers,micro porous ceramic vent plug in dry and uncharged condition confirming to rdso specification irs-s-88/2004 with latest amendments. nb- both hard rubber and pp-cp container are accepted [ warranty period: 48 months after the date of delivery ] ]

CTN :45610628 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply of 48v - lithium-ion rechargeable batteries for e-rickshaws (v2) (q3)

CTN :45330556 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For corrigendum : supply of ups 10kva-n6130-004181 , battery 12v 75ah lead acid- n0562-6140047 , battery 12v 120 ah lead acid 13" x6.5" x8" -n6140-p061653 , battery 12v 32ah for maruti gypsy-n0562-p006109 , lead acid battery 12v 5ah-n6140-005251 , battery 9v dc 400bps for epirb- n6140-p031833 , panasonic rechaegeable sealed lead acid battery-n6140-p032041 , battery 12v 7ah sealed-n6140-p062287 , battery 12v 17ah maintenance for ups siravds-n6140-p062325 , 12v 65ah sealed lead acid maintenance free battery- n6140-005258 , battery 12v 42 ah smf-n6140-005324 , lithium battery cell 3.6v-n6140-p060731 , battery 12v 26ah sealed lead acid for ups-n6140-p061364 , battery 12v 40ah mfs 40(pp) l-197 w-129 h-227 maruti gypsy-n6140-p061369 , battery 12v 80ah for hdb generator starting 12.5x6.5x8.8" -n6140-p061979 , battery 12v 60 ah-n6140-000012 , battery 12v 88ah secondary lead acid-n6140-000013 , battery lead acid 12v, 150 ah-n6140-000095 , battery lead acid 12v, 180 ah, low main-n6140-000098 , battery secondary lead acid 12v 100ah -n6140-000128 , 200 ah maintenance free battery-n6140-005365 , sealed maintenance free battery-n6140-p009506 , maintenance free battery 12v 210/200 ah-nsn6140- 720471138 , maintenance free bateery 12v 120ah- nsn6140-720471143

CTN :45581741 Due date: 01 Jul, 202601 Jul, 2026 3.63 Lacs
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c
 Loading, Please wait...

Connect us via What's Up