Web Analytics Made Easy - StatCounter

Recirculation Pump Tenders

Get complete information related to latest Recirculation Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Recirculation Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Recirculation Pump Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45715653 Due date: 15 Jul, 202615 Jul, 2026 11.78 Lacs
Tender For tender for supply of gasket.rocker lever cover for cummins make 380 kva dg set , bushing for cummins make 380 kva dg set , valve.intake for cummins make 380 kva dg set , valve.exhaust for cummins make 380 kva dg set , insert.valve for cummins make 380 kva dg set , insert.valve for cummins make 380 kva dg set , guide.valve stem for cummins make 380 kva dg set , kit.upper engine gasket for cummins make 380 kva dg set , ring.liner seal for cummins make 380 kva dg set , gasket.oil pan for cummins make 380 kva dg set , set.piston ring for cummins make 380 kva dg set , kit.barrel plunger 380kva for cummins make 380 kva dg set , panel.control for cummins make 380 kva dg set , piston.engine for cummins make 380 kva dg set , liner.cylinder for cummins make 380 kva dg set , harness wiring for cummins make 380 kva dg set , pump.gear fuel for cummins make 380 kva dg set , set.main bearing for cummins make 380 kva dg set , kit.lower engine gasket for cummins make 380 kva dg set , kit.turbocharger repair for cummins make 380 kva dg set

CTN :45720854 Due date: 15 Jul, 202615 Jul, 2026 8.26 Lacs
Tender For repair, servicing, testing and commissioning of 03 nos. hoists (capacity 05 ton) installed at intake pump house desilting chamber gate handling system and ac chiller room of unit 7 and 8, ssctps, rvun, suratgarh

CTN :45718925 Due date: 15 Jul, 202615 Jul, 2026 8.26 Lacs
Tender For repair, servicing, testing and commissioning of 03 nos. hoists (capacity 05 ton) installed at intake pump house desilting chamber gate handling system and ac chiller room of unit 7 and 8, ssctps, rvun, suratgarh

CTN :45692588 Due date: 02 Jul, 202602 Jul, 2026 16.49 Lacs
Tender For water treatment plant cleaning,purchasing of equipments for wtp, laying of di pipes and sluice valves, construction of sv chamber and phed esr repairing for jamtara nagar panchayat. - labour for site clearance -do--e/i, desilting the supply well, intake well /head works, sump of water supply /sewerage works etc. in wet or dry condition including lifts upto 9 m and lead upto 150m as required beyond the work site,stacking, spreading, including necessary guarding, etc. complete, as directed by e/i, supplying and laying of rapid sand gravity filter sand, supplying and laying of rapid sand gravity filter gravel, supplying of bamboo for scaffolding works, supplying of narial ropes for binding works submersible pump set, requirement of plumber class-ii for opening & closing of valve & other related works, requirement of electrician grade-ii for making required connections & other related works, hiring of different tools,chain pulley & tackles for cleaning & other works, disposal of excavated earth & filter bed sand, sand (lead 02k+10p=12 km), gravel (22 k.m. lead), tyre coupling (unique 3409-gn tyre coupling for 100hp & 50hp), bosch lithium based grease, graphit gland pack rope 12mm, graphit gland pack rope 16mm, 2.2kw (3hp) foot mounted motor tefc 1500 rpm 3-phase motor for clariflocculator, multi-blade paddles mounted on central shaft driven by foot-mounted geared motor, onload changeover switch 800a,415v, 4 pole, digital voltmeter (0-500v)-3 phase indicator, digital ammeter (0-500a)-3 phase indicator, led indicator lamp or phase light (r/y/b/g), pvc/xlpe insulated pvc sheated heavy duty,armoured lt cable with aluminium conductor voltage upto and including 1100 v, 240sqmm, 3.5 core, 2.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, 1.5 sqmm isi marked frls pvc insulated, single core copper conductor cable, laying of one number pvc insulated and sheated/xlpe power cable of 1.1kv grade of size not exceeding 35sqmm direct in ground including excavation, sand cushioning and refilling the trench, tapered bearing 7316 mcb (large), deep groove ball bearing 6311 mcb (small), chain pulley block hoist 5 tonne, 360 rotation, 3mtr lifting height, pipe wrench, 18 inch taparia adjustable heavy duty pipe wrench, pipe wrench, 14 inch taparia adjustable heavy duty pipe wrench, 1/2" sqaure drive flank drive taparia goti 22mm socket set, 1/2" sqaure drive flank drive taparia goti 20mm socket set, rachet wrench, 18 inch single sided rachet wrench, 1/2 inch drill bit for threading di/ci pipe, tata agrico hammer -dfs- 2.5kg, 6 inch tyton epdm/sbr rubber gasket for 150mm di pipe conforming to is:5382 isi mark, 4 inch tyton epdm/sbr rubber gasket for 100mm di pipe conforming to is:5382 isi mark, 6 inch di end cap flanged type for 150mm di pipe, 4 inch di end cap flanged type for 100mm di pipe, epdm rubber gasket for non-return valve, earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 150mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm), earthwork in excavation in foundation (as per i.s. 3114/1965 for laying of different types & sizes of pipes) so as to give one meter average cover over the the socket of pipe with disposal of excavated earth within initial lead lift as per specification & direction of e/i (k-7 100mm repair), earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches wit

CTN :45688712 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of lv7 tata 2060-4310-0102 master cylinder repair kit api consisti , lv7 tata 2525-2012-0119 repair kit water pump major , lv7 maruti 12911m71c00 valve intake , lv7 tata 2154-4290-0159 assy pipe , lv7 stln 2920-72-0471807 fd coil , lv7 tata 2540-008745 regulator vehicle window , lv7 maruti 13330-82100 diaphragm assy , lv3 icvs 8105-000959 bag spta utd- 20 sb530-200-2

Central Government/Public Sector

CTN :45376467 Due date: 09 Jul, 202609 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire

State Government

CTN :45692635 Due date: 03 Jul, 202603 Jul, 2026 19.14 Lacs
Tender For restoration of rain damages to lwss kawara kanoura in g.p.pujarli tehsil and distt. shimla. hp.(sh- construction of rcc nallah intake, connectivity of pipe line, prov. l/j of gi pipes of various dia etc., repair of pump house, fencing and electrical wiring in p

CTN :45675373 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For auction sale of others - 1 cam shaft bush bearing 1nos 2 injector pad 4nos 3 gasket intake mf 3nos 4 lever make injector 12nos 5 fuel filter 11nos 6 hose pt no 115 3nos 7 hose clip 2¿¿ for 160 kw 4nos 8 push rod for 160 kw 2nos 9 bushing for kcl 6nos 10 hose for 250kva 8nos 11 repair kit w.p 2nos 12 cyl liner [ruston] 6nos 13 super by pass filter part no -387948800k 3 nos 14 gasket for fuel filter 40nos 15 element lo 4nos 16 valve 16nos 17 starter [self] pt no -0503299 1nos 18 cylinder head 3nos 19 gasket ¿o¿ ring for air filter 90nos 20 hose turbo air connection 19nos 21 cylinder head gasket 4nos 22 hose clamp 1.5 ¿¿ 17nos 23 hose clamp 24nos 24 gasket unit 3nos 25 insert valve seat 24nos 26 oil seal [big] 2nos 27 corrosion ring plate 15nos 28 seal au drive [small] 2nos 29 tube rocker arn-lob 1nos 30 hose pt no hs 0806500ms 1nos 31 spider pt no ¿ 109859 2nos 32 piston ring 1nos 33 high pressure fuel pipe 160kw 8nos 34 fuel pump gear yd ¿ 20212 1nos 35 valve guide 10kw 4nos 36 mobil filter 160kw 4nos 37 nozzle 10kw 2nos 38 valve 10kw 4nos 39 c.r. bearing 10kw 4nos 40 main bearing 34001120 8nos 41 valve guide 25kw engine 17nos 42 gear 133.829 8nos 43 self-starter 24volt 1nos 44 transformer temperature indicator 1nos 45 cylinder head part no 1-232-180-001-7 1nos 46 self-starter 24volt 1nos 47 hydro meter 2nos 48 element lab oil turbo filter 10nos 49 element air cleaner (inner) 2nos 50 fitch fuel catalyst f-500 1nos 51 fuel filter p no- 4084133 2nos 52 self-starter ,cap -24volt suitable 1nos 53 fuel filter primary 9nos 54 fuel filter secondary 10 nos 55 set of scaling 13nos 56 tappet cover gas kit 150 nos 57 magnetic pick up 1nos 58 oil pressure switch 1nos 59 diode set 2nos 60 relay 24 volt dc 10nos 61 head gasket 9nos 62 liner o ring 2nos 63 solenoid assembly 1nos 64 c.r. bearing top+bottom 8nos 65 piston ring set 8nos 66 avr 1nos 67 avr for 5 kva d.g set 2nos 68 avr for 125 kva d.g set 2nos

CTN :45673163 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of c16m26r114 spares for recirculation pumps - cowl nut (l.h) , cowl nut (r.h) , logging ring p/n 44 , impeller(set) (full dia) p/n 31 , shaft sleeve (de + nde) p/n 514 410h , oil ring p/n 46 matl c46400 , bearing end cover p/n 363 , bearing bush p/n 23 , shaft with keys(set) p/n 84 , thrust bearing cage/ball race carrier 8 , sleeve nut (l.h) , gland p/n 26 matl ci , water thrower p/n 463 , stuffing box bush de+nde p.n 260

CTN :45633741 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For development/repair of spares for different pumps installed at 8 mgd pump house, 6 mgd pump house, raw water intake pump house -3 and clarifiers installed at water works.- rethreading/ trueness checking/reparing of shaft. , repairing/development/balancing of impellers., , development of distance sleeve/shaft sleeve., , development of impeller nut., , rectification/development of damaged keyway of pump shaft., , repairing of pump bearing housing., , repairing/development of spares of driving gear box of clarfiers.
 Loading, Please wait...

Connect us via What's Up