Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For corrigendum : supply of electrical spares c c > f> f - master trip relay , side cable box , power converter 110v ac to 110v dc , digital protection relay , epoxy resin cast current transformer
Tender For inviting expression of interest for sale of non-performing assets - power transformers (2 nos.) , rectifiertransformer, movable hoopers for bulk material uncoading at voc port-4 nos (35 ) , ms structurals channels angles, piate beams cipe rals & reinforcement asteel total wt: 2000 , aluminium cs & 55 plows with accessories-75 , coal feeding hopper along with bect conveying system 830 metres
Tender For auction sale of others - 1 road connection 4 nos 2 bolt rod part no 9195 26 nos 3 ferrule tube 40 nos 4 gasket pt no 132730 22 nos 5 ¿o¿ ring 08 nos 6 tube fuel supply part no 3225251 1 nos 7 lub oil filter 2 nos 8 assembly filter pt no 146383 2 nos 9 cam shaft bearing 1 nos 10 crank shaft bearing 1 nos 11 ring half shaft crank 16 nos 12 valve collect 8 nos 13 plug pin pt no 67622 4 nos 14 engine gasket spare 1 nos 15 cap screw pt no 5-118/a 24 nos 16 fuel filter ¿o¿ ring 22 nos 17 main bearing set 1 nos 18 cyl liner with joint ring 08 nos 19 pre element 03 nos 20 micro element 03 nos 21 element inner pt no ¿ 3230273 13 nos 22 set of hose 02 nos 23 crank shaft bearing spare 1 nos 24 element outer pt no 3230272 18 nos 25 bushing 1 nos 26 piston ring with oil scrapper 1nos 27 connecting `rod with bearing 1nos 28 `crank shaft bearing [main ] 1nos 29 cam shaft bearing 4nos 30 set main brg-std 4nos 31 piston ring set std 6nos 32 cyl head bare ra 3nos 33 l.e bolts lock ra-6 12 nos 34 ¿o¿ ring silicone 125kva 16nos 35 screw adi for kcl 24nos 36 insert valve seat 32nos 37 connecting rod complete 6nos 38 hose for 250kva 2nos 39 oil ring for 55kva 13nos 40 hose spare for 250kva 3nos 41 tube compresser5 drain for kcl 2nos 42 hose for 125 kva 4nos 43 push rod 30nos 44 valve intake for 125kva 14nos 45 valve exhaust for 125kva 14nos 46 rectifier selected switch 3nos 47 gasket thermostat 4nos 48 bracket tachometer 1nos 49 bolt con rod 4nos 50 brg con rod std 16nos 51 mounting sand switch 6nos 52 thermostat for kcl 1nos 53 ¿o¿ ring 28nos 54 spring for kcl 7nos 55 rectifiertransformer 2nos 56 hose 4 nos 57 valve guide for 160kw 2nos 58 piston ring for 200/250kva 3nos 59 piston connecting rod 1nos 60 water safety control 2nos 61 main bearing std 1nos
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of repairing and rewinding of bhel make esp rectifiertransformers unit no 3 4 5 up to 90 kva 53 point 57kv 373 point 5 v ac dc output 7..