Get complete information related to latest Redial Drill Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Redial Drill Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Redial Drill Machine Tenders.
Tender For supply of hss morse taper shank twist drill size 10.5 mm as per is: 5103-1969 or latest. make: addison or it or miranda or equivalent [ warranty period: 24 months after the date of delivery ]
Tender For supply of female welder uniform size of kurta 42" x 37" wide, size of pajama 40" x 34" x8" wide size of dupatta 2.5 meter x 1 meter wide made of 100 % cotton cloth drill navy blue variety no.3 pre shrunk quality. specification no. is: 177/1989 (4th revision ) with amdtt. 1 & 2 or latest. drg. no. jhs/misc-1563 dated-26.11.2002. [ warranty period: 30 months after the date of delivery ]
Tender For heavy duty pistol pneumatic drillmachine model no. cp-9285 mfg. by chicago pneumatic or frd-8px-1 model of fuji japan or 1117p32 model of desoutter germany makes. ( warranty period : upto 30 months from the date of supply) [ warranty period: 30 months after the date of delivery ]
Tender For supply of hydraulic rock splitter- technical specification as under (1) type of wedge set - regular, (2) suitable in drill hole dia -45-48 mm (3) splitting distance -20-50 mm (4) splitting force kn/ton-6061/618 (5)splitting force actual kn/ton -3507/358 (6) length of splitter - 1290 mm, (7) drill hole depth - 610 mm, (8) capable of developing a crack of mtr - 1.5 mtr (9) min length of wedges (i) counter wedge - 350 mm (ii) centre wedge - 600 mm [ warranty period: 24 months after the date of delivery ]
Tender For supply of drill bit for battery operated rail drillmachine ( 17. 5 mm rail tct annular cutter)part no . 240298. [ warranty period: 30 months after the date of delivery ]
Tender For supply of battery operated rail core drillmachine ( eibenstock make erd35-2 v50.4 b or similar) as per rdso specification no. tm/sm/468 dated 31.03.2014 first revision,2017 or latest. suitable clamp for 52 kg and 60kg rail to be supplied along with each machine. the suitable drill bit for sizes 7.2mm (solid drill),13mm(rail hss cutter),14mm (rail hss cutter),16mm (rail tct cutter),22mm(rail tct cutter) to be included as standard accessory in each machine. [ warranty period: 12 months after the date of delivery ]
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi