Web Analytics Made Easy - StatCounter

Redundancy Module Tenders

Get complete information related to latest Redundancy Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Redundancy Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Redundancy Module Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41273570 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For supply of control logic redundancy module, 1756-rm2 , controlnet bnc coaxial connector, , coaxial tap, 1786-tps, rockwell , digital input module, rockwell, 1756-ib32

Central Government/Public Sector

CTN :41220443 Due date: 05 Aug, 202505 Aug, 2025 NA
Tender For providing of custom bid for services - iso 50001:2018 enms-energy management system re-certification audit, registration, issue of certificate & survelliance audit at bhel trichy

Central Government/Public Sector

CTN :41267021 Due date: 13 Aug, 202513 Aug, 2025 NA
Tender For supply of components of auto block system (abs) : terminal block, end and intermediate plate & diode redundancy module

CTN :40387694 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For corrigendum : tender for supply of crash energy management system equipment - front automatic coupler , semi permant coupler , semi permant coupler , front side crash buffers , design and submission of design documents , fai reports and type test , spares for coupler , tools required for coupler , training , training manual

Central Government/Public Sector

CTN :40007770 Due date: 11 Aug, 202511 Aug, 2025 NA
Tender For corrigendum : biennial maintenance contract for ems (energy management system) make-m/s cms computers ltd at ntpc unchahar for stage#2.

State Government

CTN :40985787 Due date: 11 Aug, 202511 Aug, 2025 63.00 Lacs
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val

State Government

CTN :41183047 Due date: 29 Jul, 202529 Jul, 2025 1.80 Crore
Tender For strengthening of water supply (s/i/t/c of cloud based remote monitoring and management system intergrated with energy conservation device and plc based, cbr-mms integratable centralized

CTN :41200724 Due date: 07 Aug, 202507 Aug, 2025 NA
Tender For supply of 3 tesla mri conditional dual chamber implantable cardioverter defibrillator (ic d) df-4 with compatible leads and accessories, specification- 3 tesla mri conditional dual chamber im plantable cardioverter defibrillator (icd) system (df-4) with compatible artrial and ventricular pace / sense leads and option of single/dual shocking coil leads and accessories. system should have advanced featu res for the reliable detection and management of ventricular tachycardia and ventricular fibrillation, incl uding features to differentiate supra-ventricular tachycardia from ventricular tachycardia and features t o avoid inappropriate shocks, tiered therapy delivery, choice of atp protocols and shock energies, and s hould be capable of delivering maximum energy of 35j or more and should have features for manageme nt of high defibrillation energy requirement. charge times should be within clinically acceptable limits t hroughout the lifetime of the device. leads should be low profile and choice of both active or passive f ixation leads should be available. should have features for automatically alerting the patient in the even t of a battery or lead fault. device warranty:-full replacement international warranty of 08 years or more. the oem must have registered office with service personnel available round clock. [h/st/acs/si/lcd-dual/ 25-26/brsh ]

Central Government / Public Sector

CTN :41024834 Due date: 04 Aug, 202504 Aug, 2025 NA
Tender For corrigendum : supply of procurement of bulk power supplies and diode orings : : - 24v, 20a power supply unit , 24v, 40a power supply unit , 24v, 2x20a mosfet based diode oring redundancy module , 24v, 2x40a mosfet based diode oring redundancy module , 12-28v, 2x20a mosfet based diode oring redundancy module , 24v, 2.5a power supply unit

CTN :40875556 Due date: 01 Aug, 202501 Aug, 2025 7.50 Lacs
Tender For corrigendum : proposal to enhance data management in substations through an energy management system solution
 Loading, Please wait...

Connect us via What's Up