Get complete information related to latest Reflector Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reflector Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reflector Scrap Tenders.
Tender For corrigendum : supply of contactor 4 pole, rated voltage 1000v ac, rated kva 100 at rated voltage, control voltage 4 15v ac with 2no + 2 nc aux. contact & surge suppressor used for feeder contactor net 1 & net 2 in lhb t ype ac coaches as per rdso common bill of material letter no. el/7.1.108/mssbc dated 17/9/2021, annex ure column no.1, sr. no. 3 conforming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-0) or lat est. [ warranty period: 30 months after the date of delivery ]
Tender For contactor with surge suppressor of lhb coaches, current rating 95 amps, ac3, voltage rating 690 v ac, 50/60 hz, main pole 04 nos. aux. contact 2no + 1nc, control circuit voltage 230 v + /-15% ac, plate & rail mounting support, standard iec/en 60947, suitable for fitment lhb coaches swit ch board cabinet local main supply, 1 & 2 item code s1k41, s1k42 & s1k43 contactor of lhb ac coach es, degree of protection ip20, cat no. lcifdp1154u5+la9f980 (br) of c&s or lc1d1150046p7+ladn 2 or lc1d1150046m7/m5+la4da2u (220v ac) of schneider or af116b-40 of abb only. material to be supplied with oem proof of purchase & test certificate. spec:rdso spec no.rdso/pe/spec/ac/0184-20 15 (rev-1).make-c&s/schneider/abb only. [ warranty period: 30 months after the date of delivery ]
Tender For populated main pcb for suntron ecu (timer card/control card) for all cls pane l like 30a. 60a. 150a. 300a. contactor 150a 2pole 2no-2nc for 25kva at (spare part suitable fo r suntron make cls panel) as per rdso specification no:- eti spc psi cls 0020 or latest make - su ntron or similar. make- suntron or any other make suitable for cls panel of suntron make provided i n jabalpur division of west central railway. (firm should integrate the item with the existing system.) warr anty period: 30 month(s) from the date of supply. [ warranty period: 30 months after the date of delivery ]
Tender For :provision of water facility at slf bhalswa - boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in is: 2800 (part i), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer-in-charge, upto 90 metre depth below ground level. all type of soil (350 mm dia), boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in is: 2800 (part i), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer-in-charge, upto 90 metre depth below ground level. rocky strata including boulders-350mm, gravel packing in tubewell construction in accordance with is:4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement, all complete as per direction of engineer-in-charge., development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. the development shall be considered complete when gravel stop sinking, discharge ceased to improve and the sand contents are not more than 10 ppm after 20 minutes of starting the pump complete as reqd., providing, lowering and fixing/placing in vertical position ms black casing medium ( b-class) pipe of following size conforming to is 1239/3589 part-i (2004) at all depth, both ends threaded as required.(a) 200 mm dia. (nominal bore), providing, lowering and fixing/placing in vertical position ms slotted casing medium ( b-class) pipe of following size conforming to is 1239/3589 part-i (2004) at all depth, both ends threaded as required.(a) 200 mm dia. (nominal bore), providing, lowering and fixing/placing in vertical position ms slotted casing medium ( b-class) pipe of following size conforming to is 1239/3589 part-i (2004) at all depth, both ends threaded as required. (b) 150 mm dia (nominal bore), providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell. (a) 200 mm dia., supply, lowering and fixing following size of g.i. pipe (m-class) i/c cutting threading on both sides etc. isi marked etc as reqd. (d). 50mm(nominal bore), s & f following size of g.i. elbow. as reqd. (d). 50mm, s & f ms clamp made up of iron flat of size 50x6 mm with 4 nut bolt for holding the gi pipe as reqd. (b) 50 mm., providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 50 mm nominal bore, supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. (e) three phase 7.5 hp having discharge of 480 lpm approx. at 48 m head., s&f following size of g.i.socket as required. 50mm, s&f following size of g.i.union as required. 50mm, p&f following sizes of pvc insulated & pvc sheathed copper conductor 3 core submersible cable confirming to is.694/1990 etc. as reqd. (b) 3x 4 sq.mm., supply of cubical type control panel board for three phase star delta starter, three position selection with auto switch for submersible pumping set of following rating complete with single phasing preventer in auto, contactor (25amp), 0/l relay tp, mcb, voltmeter, ammeter, vss and indication lamp etc. including lamp etc. including connection etc. as required. (a) 10 h.p. rating submersible pump set over load relay (range13-21 amp) & contactor (range 25 amp)., supplying and fixing following sizes of steel flexible safety rope for holding s
Tender For supply of electrical spares - electrical spares, digital synchronous timer for switching on/off operation, cycle duration -24 hours, maximum number of switchings 48 on-48 off, contact voltage/current rating- 240vac/16a, changeover contacts- 02 nos. din rail mounting type, minimum time interval 15 min for 24 hrs. make selec, l& t, c&s, abb, havells, legrand only, power contactor 80a, coil voltage-240vac, 1 no-1nc, din mounted , abb, schneider/havells/ lnt/ hager/c&s/legrand/bch only, mcb 16a, single pole, c curve, breaking capacity-10ka, make : abb, schneider/havells/ lnt/ hager/c&s/legrand/bch only, fuse hf type, 32 a, 415 v, fuse hf type, 63 a,415 v, magnetic oil level gauge (mog) for 12.5 mva rating oil type transformer.size 150mm , suitable for vertical mounting., timer on delay a1d1-x eapl ,3 sec-30min , din rail mounting type, pendent 6 waymaterial: high grade plasticvoltage rating:415 vaccurrent rating:5ampwith emergency stop & start/alarm, with ip65 dust proof for outdoor application, control transformer415/110vac, 500va , winding material - copper , maximum size in mm w x d x h = 160 x 100 x 200 , control transformer415/110vac, 300va , winding material - copper maximum size in mm w x d x h = 160 x 150 x 160, control transformer415/110vac, 1000va , winding material - copper maximum size in mm w x d x h = 150 x 150 x 180, control transformer415/110vac, 3000va , winding material - copper maximum size in mm w x d x h = 200 x 160 x 300, bridge rectifier input voltage 415 vac output voltage 190 vdc, fuse ctis, bolted type, 63 amp , 415 vac, fuse hbc, bolted type, 32 amp , 415 vac, hrc fuse base for 100a hn type fuse , 415 volt, limit switch with 1no + 1 nc , 415 volt , 50 hz , 1.5 amp .these limit switches should be equivalent to original installed model: bc9 t limit switch (jlsla) of jaibalaji make
Tender For supply of contactor for net 1 & 2, rated voltage 1000 v ac. rated kva 100 at rated kva 100 at rat ed voltage & 70 deg. c and utilization category 6 a, main pole 4. aux. contact 2 no + 2nc, control volt age 415 v ac with surge suppressor suitable for feeder contactor for net 1 & 2 place of installation s1k 01 & s1k02. make accepted - 1) m/s. schneider cat no lc1d1150046n5+ la4da2n + ladn22 or 2) m/ s. abb cat no af190b-40-22 or 3) m/s. siemens cat no.3rt23461av004aa0+3rh29111ha11+3rt 29 361be00 or 4) m/s. l&t part no. mcx-34 only. conforming to rdso/pe/spec/ac/0192-2018 (rev.1) as per rdso letter no. el/1.7.108/mssbc dated 17.09.2021. note:- oem or authorized dealer with vali d dealership certificate should only quote. [ warranty period: 30 months after the date of delivery ]
Tender For contactor with surge suppressor of lhb coaches, current rating 95 amps, ac3, voltage rating 690 v ac, 50/60 hz, main pole 04 nos. aux. contact 2no + 1nc, control circuit voltage 230 v + /-15% ac, plate & rail mounting support, standard iec/en 60947, suitable for fitment lhb coaches swit ch board cabinet local main supply, 1 & 2 item code s1k41, s1k42 & s1k43 contactor of lhb ac coach es, degree of protection ip20, cat no. lcifdp1154u5+la9f980 (br) of c&s or lc1d1150046p7+ladn 2 or lc1d1150046m7/m5+la4da2u (220v ac) of schneider or af116b-40 of abb only. material to be supplied with oem proof of purchase & test certificate. spec:rdso spec no.rdso/pe/spec/ac/0184-20 15 (rev-1).make-c&s/schneider/abb only. [ warranty period: 30 months after the date of delivery ]
Tender For populated main pcb for suntron ecu (timer card/control card) for all cls pane l like 30a. 60a. 150a. 300a. contactor 150a 2pole 2no-2nc for 25kva at (spare part suitable fo r suntron make cls panel) as per rdso specification no:- eti spc psi cls 0020 or latest make - su ntron or similar. make- suntron or any other make suitable for cls panel of suntron make provided i n jabalpur division of west central railway. (firm should integrate the item with the existing system.) warr anty period: 30 month(s) from the date of supply. [ warranty period: 30 months after the date of delivery ]
Tender For supply of contactor for 60kva transformer , rated current : 95a, rated voltage : 690 v ac, main pole- 4, along with auxiliary contact : 1 no+1 nc, control voltage : 230 v ac (168 v ac-300 v ac means 230 v a c +/- 30%) with surge suppressor confirming to rdso bom letter no el/7.1.108/mssbc date 17.09.2021. c ontactor shall only be either of make : abb ( model - af 116b-40) or schneider (model - lc1d1150046m5+ la4da2u). or c&s make(lc1fdp1154u5 +la9f980 (br) . [ warranty period: 30 months after the date of delivery ]