Tender For development work and services of crc hostel building at patna. (sh:- supply of net metering system for rooftop solar pv system at crc hostel building, patna.)
Tender For survey design manufacture supply installation testing and commissioning with 5 years comprehensive maintenance contract of 25 kwp capacity grid connected solar pv power plant under rooftop net metering system with rms
Tender For corrigendum : supply of microprocessor based 0.2s accuracy class abt compliantand ht tariff compliant static metering system along with gprs or otherlatest technology modem and ttb
Tender For corrigendum : tender for supply of e4253014 for energy metering system for ntpc lara : - e4253014 ems 01-sg4935117435-em- line abt as per it-01 annx-01. , 02-sg4935117443-em-br abt as per it-02 annx-01. , 03-sg4935117451-em-st abt as per it-03 annx-01. , 04-sg4935117460-em-gt abt as per it-04 annx-01. , 05-sg4935117478-em-g abt as per it-05 annx-01. , 06-sg4935107103-em-ut abt as per it-06 annx-01. , 07-sg4935117486-em-station board as per it-07 annx-01. , 08-sg4935117494-em-station to unit tie as per it-08 annx-01 , 09-sg4935117508-em-solar abt as per it-09 annx-01. , 10-sg4935117516-em-11kv colony abt as per it-10 annx-01. , 11-sg4935117524-mri as per it-11 annx-01. , 12-sg4935117532-mms alongwith other accessories as per it-12 annx-01.
Tender For installation testing and commissioning of 110 kw ground mounted solar pv system using 590 wp bifacial modles mounting structure supply and integration of all balance of system component inverts structures cabling metering protections remote monitoring civil structural and electrical works as per requirement at indi road in vijayapur city corporation through jala hi amrut grant scheme
Tender For tpj division - replacement of manual metering system with advanced contact less smart energy metering system in various vendor stalls, private contractors office, restaurants and union offices (phase - i) - electrical arrangements - workscontract
Tender For corrigendum : supply of resistance load bank - resitance load bank, resistive load bank 250vdc and 250 acontinuous rating with the following description:- load steps: 5a - 2 nos. , 10a 1 no. , 15a 1 no. , 20a 1 no. , 25a - 3 nos. , 30a - 4 nos. resistance tolerance: +/-5% load switching means: 2p mcb aux. supply switching means: 1p mcb load input terminations with bus bar with m12/m10 nut/bolts aux supply terminations 3 pin, 16a, circular panel mounted socket. metering: dc multifunction meter operation mode: manual protections: overload/short-circuit panel details: material - ms , material thickness - 16 gauge powder coating with castor wheels at the bottom of the panel for easy mobility cooling system:- forced air cooled , flow direction: vertical, mesh at the incoming and outgoing port of the cooling system application: battery testing
Tender For corrigendum : creda invites online tender for survey, capacity assessment, design, supply, erection, testing and commissioning including warranty, operation & maintenance for 25 years grid connected roof top solar pv system capacity of 1.3mwp {2x650kwp(dc)/2x500kw(ac)} at late shri lakhi ram agrawal memorial medical college building & late shri lakhi ram agrawal memorial hospital building, raigarh, chhattisgarh under resco model on net-metering basis.