Tender For supply of cold storage room and split ac c c - c73340300387 supply of high wall mount type hot and cold split ac units of cooling capacity not less than 2point0 tr minimum 3 star rating inverter type rotary refer atc document , 100000000001 supply of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac hot and cold units capacity 2 tr for suction liquid refer atc document , 100000000002 supply of outdoor stand suitable for outdoor unit refer atc document , 100000000003 supply of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units to nearest drain point refer atc document , 100000000004 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy 1point1 kv grade lt cable of size 4point0 core 2point5 sqmm refer atc document , c73340100276 supply of cold storage capacity minimum 20,000 btuperhr 1 working and 1sb overall considering both chamber with following specification as puf walls panel min 80mm with refer atc document , 100000000005 supply of kota stone for flooring along with pcc foundation for the installation of cold storage refer atc document , 100000000006 installation testing and commissioning of cold storage capacity minimum 20000 btuperhr 1 working and 1sb along with panels cabeling,copper piping etc complete refer atc document , 100000000007 installation of foundation along with pcc foundation suitable for cold storage refer atc document , 100000000008 dismantling and shifting of existing cold storage capacity minimum 20,000 btuperhr 1 working and 1sb along with panels foundation and flooring complete refer atc document
Tender For supply of 3 nos. air cooled package air conditioners of cooling capacity (17.5+/- 1.0) tr each (2 working + 1 standby) for visual inspection room 1,2,3 & 4 in urm-& its erect/ installation ,testing & commissioning of bhilai steel plant.
Tender For maintenance contract of turbine and auxiliaries in a thermal power plant of 2x500 mw dtps anpara b b - overhauling of tdbfp aop onejob consists of one pump , major inspection or overhauling of tdbfp eop onejob consists of one pump , cleaning inspection and rectification of tube leakages if any of lube oil coolers of mdbfp onejob consists of one cooler , cleaning inspection and rectification of tube leakages if any of working oil coolers of mdbfp one job consists of one cooler , inspection oroverhauling of cot or dot room transferoil pumps one job consists of one pump , overhauling of transfer oil pumps or gear oil pumpsand other similar pumps one job consists of one pump , replacement of coupling of transfer oil pumps or gear oil pumps or tdbfp jops and other similar pumps one job consists of one pump , axial and radial alignment of transfer oil pump or recirculation pump or tdbfp jop cot or dot room transfer oil l pump and other similar pumps one jobconsists of one pump , overhauling of vapour extractor of mot or control fluid tank or tdbfp oil tank and seal steam system one job consists one vapour extractor , cleaning of centrifuge bowl of tdbfp one job consists of one centrifuge bowl , overhauling of recirculation pump of vacuum pump , cleaning of tdbfp oil tank one job consists ofone oil tank , cleaning of main oil tank of turbine or cot or dot one job consists of one tank , alignment and adjustment of recirculation pump withmotor , cleaning of centrifuge bowl of main turbine and cot or dot one job consists of one centrifuge bowl , replacement of the burst atmospheric relief diaphragm of lp turbine , inspection or cleaning flushing and normalization of condenser hot well , inspection or cleaning flushing and normalization of deaerator , inspection or cleaning flushing and normalization of feed water storage tank , inspection or cleaning flushing and normalization of tg or sg ecw tank one job consists of one tank , replacement of turbine hp orlp bypass oil and minor revisioning of hp bypass oil system , centrifuging of lube oil through portable centrifuging machine , inspection or cleaning of sg plate heat exchanger , inspection or cleaning of tg plate heat exchanger , inspection cleaning and revisioning of acw pump suction strainer one job consists of 01 strainer , filling flushing and normalization of tg or sg ecw system one job per cooling system , cleaning and revisioning of tdbfp aop suctionfilter one job per filter , cleaning and revisioning of duplex lube oil filterof tdbfp one job per filter , cleaning and revisioning of eop filter of tdbfp , cleaning and revisioning of lube oil filter of mdbfp one job per filter , cleaning of duplex lube oil filter of main turbine one job per filter , cleaning of jop duplex filter of main turbine one job per filter , cleaning of bucket filter of main oil tank or control fluid tank one job per filter , cleaning of self cleaning filter of protection rack of main turbine 1 job consists of two filters , inspection or replacement of dry filter or mechanical filter super fine filter one job per set , inspection or replacement of fuller earth filter one job per set , cleaning of duplex filter mounted on valve rack of governing system of main turbine one job per filter , cleaning of cep suction strainer or bfp booster pump suction strainer one job per strainer , cleaning of bfp conical strainer one job per strainer , revisioning or replacement or cleaning of pilot valve of main turbine one job consists one pilot , revisioning or replacement or cleaning of pilot valve of m c v or aux c v of tdbfp one job consists one pilot , servicing of isolating valve control valve and nrvsof condensate line tdbfp extraction extraction 5 and booster pump suction line //bid details3 / 108size400 mm class150 to 300 , servicing of isolating valve control valve and nrvs installed on bfp discharge feed discharge line hph inlet or outlet hph 50 percentage bypass and other similar valve , servicing of hph 100 pe