Get complete information related to latest Reinforcement Steel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reinforcement Steel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reinforcement Steel Tenders.
Tender For material supply for the installation of 4 line hanging solar power fence at rajapuram estate - hanging solar power fence, p.p reel insulator , must be of virgin plastic metirial. polypropylene or equivalent with break down voltage of 15 kv(weight 25gm avg, length 4.6 cm avg), strain insulator, must of poly polypropylene plastic rated for 15 kv uv stabillized ,(weight 40 gm avg, length 7 cm avg), gi post 12 feet , 2" gi pipe, 14 guage thickness,total 14.5 ft length modified to 12 feet length and cut and welding to 90 degree bend 2.5 feet length at top end and having diametrically opposite holes of size 6 mm at end of bend pipe, intermediate post (t angle post) , 6ft., painted(25mm*25mm*3mm)having holes of size 6 mm at required interval of fencing installation, supporting post, 10ft.,gi-1,14 guage thickness,painted, stay (t angle), 2ft., painted(25mm*25mm*3mm), 12 swg ht wire, 12 guage,2.5 mm dia high tensile wire with zinc coating for use as conducting wires,binding strain insulator, 14 swg binding wire , high quality zinc coating wire for binding reel insulator, tighing support post with corner post, 1.5 mm stainless steel wire rop 304 grade, aluminium ferruel, aluminium ferruel 3 mm, wire tightner , permanat wire tightner made of special aluminium alloy designed for kv, uv stabillized, earth rod, copper plated earth rod 14 mm -3ft. length, earthing compound, earthing compound 8 kg, gate handle, gate handle and spring assembly, handle made of polyethylene, leadout cable,leadout cable for fence system double insulated gi cable inner core wire 2 sq.mm.hot dipped galvanised steel core, capaie of with standing 15kv should be provided to prevent bimetal salt formation at connections, single core 2.5 mm sq. cable, 2.5 mm2 single core copper cable for connecting the solar panel to the tubular battery through charge control unit with required terminal sockets,nut and bolt,washer, lightning diverter, 15kv -50kv rod gap arrester,must be capable of diverting stray lightning and adjustable for spark gaps adequate earthing to be provided, 100 watt solar panel, 100 watt/12 volt and above poly cristalline with 10 year warranty having iec/mnre certification, charge control unit, 20 a,12/24 pwm charge controller unit of standard make suitable to control the charging of the tubular battery, energizer, energizer with 10 kv output safety standards to be followed are bis 302-2-76 iec60335-2-76. switch-high, medium and low power setting., fence alarm system, fence alarm system covering area of 1.5 km, solar panel sapporting stand with metal box painted (for battery and energiser), 18 guage thickness metal box(lockable). gi-sheet, painted should be capable of housing battery, charge controller and energizer and fixed with reguired clamps and nut and bolt on solar panel suppoert stand made of gi pipe of 50mm diamere and b class type with suitable arreangement for holding the panel, warning sign, polyethylene plastic with satuatory wrning with signs, tubular battery 12v , 100ah, 12 v, 100 ah c10 rating with full 5 year replacement warranty (tower battery) for energising the energiser
Tender For material and labour for construction of view cutting fence (2200 mtr) in ferozepur - site clearance complete all as specified and as directed. , excavating in trenches, not exceeding 1.5 m wide or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified & directed., , excavating in post holes each n. exc. 0.5 cum and getting out in soft lloose soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm complete all as specified., , material and labour for providing cement concrete in foundations 1:4:8 type d2 (using 40mm graded stone aggregate) filling and mass concrete complete all as specified & directed, , material only for brick work with bricks class designation 75, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed., , material and labour for providing cement concrete 1:2:4 type b1 using 20mm graded aggregate as in copping including weathering, slightly rounded or chamfered angles and necessary formwork complete all as specified and as directed, , material only for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and as directed., , supply and fix rolled mild steel fe-410 (grade e-250a) angle or tee section as in post, cut to length and bend to shape as directed, fixed independetly without connecting plate etc, including provision of 05 to 06 nos gaps/outs/holes in each post for providing/laying ppgi sheet and one coat of red oxide zinc chrome primer after preparation of new steel surfaces complete all as specified and as directed., , supply and fix rolled mild steel fe-410-w (grade e-250) quality a framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed., , supply and fix of pre-painting galvalume sheets having pitch 190mm, depth 29mm and not less than 0.50mm thickness having tensile strength of 550 mpa (galvalume base-ppgl trapezoidal profile sheets) fixed with self tapping screws of size 75/100mm and aluminium washer of suitable size in view cutting complete all as specified and as directed.
Tender For fixing bell mouths bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the engineer-in-charge. size of the main with which connection is to be made. 1. up to 200 mm internal diametre ,manhole chambers providing and fixing sfrc manhole covers and frames marked with is: 12592 including setting the same to correct lines and levels in 1:3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the engineer-in-charge. 1. type:- extra heavy duty set (ehd-35) 560mm clear opening, earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer - in - charge. 2. nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 6. 1:4:8 (1 cement : 4 coarse sand (zone-iii) : 8 graded stone aggregate 40 mm nominal size) .,steelreinforcementsteelreinforcement for r.c.c. work, where not included in the complete rate of rcc, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level note: reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. thermo-mechanically treated bars of grade fe-500d or more,brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor iv level in all shapes and sizes in : 1. cement mortar 1:4 (1 cement : 4 coarse sand)
Tender For bid to ras supply of site clearance and amp earthwork is 1200 , kero heater , pcc is456 , rcc m20 footing and column and slab , reinforcementsteel fe500 , brickwork 230mm is1077 and flooring anti skid , internal plaster 12mm , doors flush and windows alluminum and glass , electrical led and wiring , plumbing and sanitary , ceiling gypsum vip , painting exterior and interior external lighting and poles , water supply tank and pump , transportation and logistics remote area , contingencies and solar panel 5kva and invertor and battery 5kva , generator 5 kva electrical led and wiring is 732 , mirror 5 h 2w ft and bench 5 h 2w ft , chair plastic with arm , toilet sheet western with exhaust fan and water faucet and hand jet assy , electric fitting work , changing room 6 by 6 by 10 ft and bathroom 6 by 6 by 10 f , multipurpose hall structure , chair vip sofa and centre table , podium and tt table and carrom set , yoga mats fire extinguisher , 86 inch interactive pannel , drainage and cement road work tin shed wk on viewer seating iron poles and tin sheet hooks screw and iron channel , ground civil work , excavation work
Tender For supply of 8mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 10mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 12mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 16mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 20mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 25mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 28mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786 , 32mm dia reinforcement bar fe500d hysd reinforcementsteel confirming to is 1786
Tender For supply of modular toilet (q3) , galvanized steel chain link fence fabric (v2) conforming to is 2721 (q3) , white led based solar home lighting system with batten type luminary as per mnre specifications (q3)