Get complete information related to latest Relay Card Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Card Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Card Tenders.
Tender For supply of relay ac immune plug in type style qbca1 dc biased point contractors, 24v, 2f(hd), 4 b contact, front contacts (heavy duty) and back contacts metal to carbon complete with plug board, r etaining clip & connectors confirming to brs:943, irs:s-34 and irs:s23 and configuration approved by rdso. the interlocking code for this unit shall be bcejk. [ warranty period: 30 months after the dat e of delivery ]
Tender For corrigendum : tender for supply of o ring , o ring , o ring , element for suction filter , actuator seal kit , o ring , o ring , o ring , o ring , oring 1/8 , solenoid valve connector , rotary selector switch , ethernet round shell connector rjftv plug , ethernet round shell connector rjftv receptacle , vme rack 6u/ 33hp , cooling fan 24v dc , relay , illuminated push button 24v dc red , illuminated push button 24v dc green , push button red 22 5 mm 2am4 , ethernet switch 8 port un managed , round shell connector box mount 24 pin male , o ring , hose assy. 1/4 bsp , hose assy. 1/2 bsp , flexible hose assy. , hand pp filter seal kit , power supply input 230vac output 24vdc/10 amp , digital input module 16-channel , digital input module 8-channel , rotary switch 2pole on/off 16 amp , buzzer , indicating lamp 24v dc red , contact pins , round shell connector plug 24 pin female , round shell connector box mount 10 pin male , round shell connector plug 10 pin female , o ring 12mm , drive screw , rolled pin , backup ring , seal 1 1 2 bonded , solenoid valve , seal retainer , bearing assembly , seal bonded 3/4 , screw m8x40mm , o ring 8mm , o ring 30mm pipe
Tender For timer relay (off-delay) (true delay on break) i) supply voltage:24 to 240 v ac/dc ii)mountin g type:din rail iii) number of contacts: 1 iv) time range:0.05s to 10min v) mode of operation:off delay w ithout auxiliary voltage vi) number of timer function: single vii)contact configuration: spdt viii) current m aximum:4a ix) terminal type:screw as per rdso specification no.rdso/pe/spec/ac/0184 2015 rev.1 & r dso letter no.el/7.1.108/mssbc, dt.17/09/21 to abb model no.ct-ars.11s or siemens modelno.3rp2540 1aw30 or carlo gavazzi model no. dbb02cm24 or schneider modelno.re22r2kmr or l&t 23gdt0 or dold model mk7873n or phoenix model etd -bl-1t-230pt or luetze make: as per bill of material of rds o specificationno.rdso/pe/spec/ac/0184 2015 rev.1 & rdso letter no.el/7.1.108/mssbc,dt.17/09/21. [ warranty period: 30 months after the date of delivery ]
Tender For supply of electrical and misc items d d - clamp grndg gi 70 sqmm , crc cleaner contact 400ml , earth leakage relay with cbct 12v 1-750ma , earth leakage relay digital 110v 50-750ma , relay overload thermal 80-110a 550 v ac
Tender For corrigendum : supply of laboratory equipment and instruments - analog electrician tool kit upto 200 ma , c clamp 100mm , c clamp 200mm , chisel cold 25mmx200mm , tweezers 150mm , double ended open spanner set 6 7mm to 30 32mm 12 no. spanner in each set , contactor 3 phase 415v 25a with 2 no and 2 nc , contactor 3 phase 415v 32a with 2 no and 2 nc , limit switch liver operated 2 a 500v 2 contact , rotary switch 16a 440v , over current relay 16a 440v , voltage monitor relay 190 to 440v , hydrometer , mccb 100a 3 pole , elcb 25a 2 pole 30ma sensitivity , digital multimeter dc 200mv to 1000v 0 to 10a and ac 200mv to 750v 0 to 10a. resistance 0 to 20mohm and 31 by 2 digit , lux meter 0.05 to 7000 lumen with battery , phase sequence indicator 3 phase 415v , discrete component trainer for diode and transister circuit with regulated power supply plus 5 0 to 5v plus 12 0 to 12v , digital i.c trainer 7 segment display and bread board , energy meter single phase 2 wire 240v , energy meter 3 phase 4 wire 415v
Tender For supply of silver impregnated graphite contact for plug in type relay to irs:s-67-85 amendment-2 and as per drawing no- sw/qr/90/n or s&t/by/qsr-44. only rdso approved source or its authorised dealer to quote. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of spares for abc electricals pvt ltd make flpstarter drillcontrolpanel gateendbox lightingtransformer - chasis wired up with all components fdb 100a dol , isolator reversing 300a fdb 101 c dol , sensetive earth leakage relay up to 750 ma fdb 114ma dol , main contactor 90 150 hp fdb 102 b dol , main contactor kit for 90 150 hp fdb 102 b2 dol , thermal overload ct operated fdb 109bn dol , isolator reversing 300a fsd 101c sds , internal chasis wired up 150kw 200hp fsd 136 sds , contactor for 100 175 hp fsd 102a sds , contactor kit for 100 175 hp fsd 102 a2 sds , contactor for 190 250 hp fsd 102b sds , transformer panel with all components but without transformer , transformer only , electromagnetic earth leakage system , earth leakage relay , pilot relay , bridge rectifier unit , diode , condenser , relay base with wiring , hrc fuse base with carrier , main contactor 25 amps , contactor spare kit 25 amp , thermal overload relay , neutral resistor , resistance for pilot relays , test reset microswitch , leakage indication lamp , leakage indication lamp holder , 30a restrained plug and socket complete , terminal with insulator bushing , bush insulator for terminal , isolator switch 40 amps , front cover bolt , top cover bolt , sensitive earth leakage relay up to 750 ma , sensitive cbt for 750 ma earth leakage relay , mechanical latch type earth leakage relay with contact block , isolator reversing 200a , isolator reversing 300 a , copper busbar 300a with sleeving r y b , 150a restrained plug and socket complete , main contactor 200 amps , auxiliary contactor , magnetic overload relay , sensitive cbt for earth leakage relay 750 ma , selenium bridge rectifier , auxiliary transformer 100va , auxiliary transformer 150va , auxiliary transformer 250va , ct for overload , test microswitch , start stop microswitch , chasis wiring complete with all components including elr cbct , single phase preventor , plug and socket assy. comp. 200 amp sdl side , plug and socket assy. comp. 200 amp geb side , pt for lighting transformer 400va 550v 12v 24v sdl side , fail safe relay to ensure continuity between neutral and the ground , transformer panel complete with all component without transformer , internal chasis wired up with all protections , control transformer , terminal with insulatar incoming throughgoing interconnecting , outgoing terminal , copper busbar with sleeving r y b , isolator switch , earth leakage relay sensitive up to 750 ma , throughgoing cable box with gland and lead cone , sensitive cbt for 750 ma earth leakage relay
Tender For supply of providing and fixing of lightning conductor finial. , jointing copper or g.i. tape with another copper or g i tape , providing and fixing g.i. tape 20 mm x 3 mm thick on parapet or surface of wall , providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess , repairing rewinding of 1 hp capacity centrifugal pump , repairing rewinding of 2 hp capacity centrifugal pump , repairing rewinding of 3 hp capacity centrifugal pump set , repairin rewinding of 5 hp capacity centrifugal pump set , repairing rewinding of 1.5 hp capacity submersible pumpset , repairing rewinding of 2 hp capacity submersible pumpset , repairing rewinding of 3 hp capacity submersible pumpset , repairing rewinding of 5 hp capacity submersible pumpset , sitc of submersible pumpset of 2 hp water filled , sitc of submersible pumpset of 4 hp water filled , lifting and lowing of submersible or borewell pump upto 5 hp alongwith gi pipe , lifting and lowing of submersible or borewell pump upto 5 hp alongwith hdpe pipe , repairing rewinding of 2 hp sump pump set , repairing rewinding of 3 hp sump pump set , repairing rewinding of 5 hp sump pump , replacement of faulty foot valve of size 40 mm dia , replacement of faulty foot valve of size 50 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 20 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 40 mm dia , replacement faulty gate valve with brass forged or gun metal valve of 50 mm dia , replacement of nrv with new nrv made up of brass of size 40 mm dia , replacement of nrv with new nrv made up of brass of size 50 mm dia , supplying and fixing 20 mm dia b class medium g.i pipe , supplying and fixing 40 mm dia b class medium g.i pipe , supplying and fixing 50 mm dia b class medium g.i pipe , supplying and fixing 20 mm dia heavy duty upvc pipe , supplying and fixing 40 mm dia heavy duty upvc pipe , supplying and fixing 50 mm dia heavy duty upvc pipe , replacement 3 pole power contactors type mnx 12 , replacement 3 pole power contactors type mnx22 , replacement of mounting add on aux. contact block suitable for 9 a to 30 a , replacement of thermal overload relay suitable for mnx contactor range from 0.2 a to 23 a , supplying of 3 x 2.5 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 4 x 16 sq. mm aluminum conductor cable of 1.1kv grade , supplying of 3.5 x 35 sq. mm aluminum conductor cable of 1.1kv grade , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm direct in ground , laying of one no. cable of 1.1 kv grade and size upto 35 sq.mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on cable tray , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing rcc or hume or metal pipe , laying of one no. cable of 1.1 kv grade and size upto 35 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm in existing masonry open duct , laying of one no. cable of 1.1 kv grade and size //bid details 3 / 138 upto 35 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 35 upto 95 sq. mm on wall surface , laying of one no. cable of 1.1 kv grade and size above 95 upto 185 sq. mm on wall surface , s and m end termination with brass compression gland and aluminium lugs for 2 x 6 sq.mm al cable. , s and