Get complete information related to latest Relay Card Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Card Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Card Tenders.
Tender For supply of relaycard of tayal & co make for fire/smoke detection with alarm system as per rdso specification no rdso/2008/cg-04, rev-06 orlatest. [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of electrical spares and consumables for 220 kv and 33kv switch yard at khodri power station - 245 kv lightening arrester, discharge current 10ka, frequency 50 hz,pressure relief class 40 ka(rms), long duration discharge class 3, m.c.o.v. 56 kv, make: oblum electrical industries pvt. ltd. /cg power and industrial solution ltd. or eq make as approved by engineer in charge., 145 kv lightening arrester outdoor type ,suitable for 145kv system voltage , discharge current 10ka, freq. 50 hz, high current impulse (4/10 s) 100 ka, rated lightning impulse withstand voltage 1.2/50 s - 650 kvp, polymer based (single phase) make-oblum electrical industries pvt. ltd. /cg power and industrial solution ltd,/ htachi / siemens india ltd or eq make as approved by engineer in charge., auxiliary switch (stack) 5no + 5nc, 220v, dc, make: crompton, hitachi or eq make as approved by engineer in charge for 220kv cgl make sf6 circuit breaker., surge monitor/surge counter with leakage current meter suitable for 220 kv lightening arrestor , make: cg power and industrial solution ltd./ oblum electrical industries pvt. ltd., 33kv ct indoor type , 3 core, 15va each, ratio 650-350/1 a + 1a , class 0.2s(2 core metering) & 5p10 (protection), str: 25ka for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge., 33kv ct indoor type, 3 core, 15va each, ratio 300-150/1 a + 1a , class 0.2s( 2 core metering) & (5p10 protection, str: 25ka, for 3 sec. make siemens, crompton, hitachi or eq make as approved by engineer in charge, control motor, type c21, 2.6 a, 230v ac/dc, o/p 0.3kw, sr. no: 042-901, m/y 03/08, 750/ min. make: kpt shirol or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 7no+6nc (stack), 250 volt dc, make: crompton, hitachi or eq make as approved by engineer in charge for 33kv cgl make indoor type sf6 circuit breaker., auxiliary switch 8no+ 8nc, 220v, dc, (motor drive ). make: abb/ hitachi or eq make as approved by engineer in charge for 245 kv, abb make isolator., 220 v, dc, close or trip-1 coil ( part no. exin - 400834 - r9)make: abb/hitachi or eq make as approved by engineer in charge for 145kv, abb make sf6 breaker., rectifier 15 a, 220 v, ac (part no. 1hyn-450040p1 ) make: abb/ hitachi or eq make as approved by engineer in chargefor 245kv, abb make isolator, mcb (2 pole,3a, 220v, dc ), over current earth fault relay, mc61a-nx, cat no : mc61anx2200, make: l&t electrical & automation, or eq make as approved by engineer in charge for 33kv sf6 braeker., 33kv busbar support insulator (epoxy) . make: universal engg. corporation,star electrical engg. works or eq make as approved by engineer in charge.(as per sample), epoxy bushing/ fixed contact of "r","y" &"b" phase bottom side for 33kv cgl make panel (as per sample), epoxy bushing/ fixed contact "r","y" &"b" phase top side for 33kv cgl make panel (as per sample), ratech wheel of 33kv sf6 breaker, cgl make, flexible contact of 33kv sf6 breaker finger, cgl make (as per sample), silica gel blue crystal in mesh size of 15 mm to 35 mm duly packed in poly lined moisture proof m s drums/carton, heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 400mm ,33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- 185 mm 33 kv xlpe cable for indoor application (make 3m/raychem/ densons)., heat shrinkable cable terminal kit for 3- , 185 mm 33 kv xlpe cable for outdoor application (make 3m/raychem/ densons)., p g clamp deer/panther for 220 kv conductor, p g tclamp deer/ zebra, for 220 kv conductor, p g clamp deer/ trantulla for 220 kv conductor, p g clamp tarantula/ trantulla for 220 kv conductor, p g clamp deer/deer for 220 kv conductor, p g clamp made of aluminum-alloy suitable for zebra to trantulla conductor with 4 nos bolt - n
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For supply of e4963013 01 3element transformer protection aux. relay model: vaa31(2no contact sr) /element, with aux , 02 tcs relay(95) , vax31, (2no+ 1nc) with aux supply 24 v dc) as per ann-a, item - 02.
Tender For corrigendum : supply of supply of 220 kv line protection panel (with automation) , retrofitment including installation, testing & commissioning of 220 kv line protection panel , supply of 220 kv circuit breaker relay panel with auto reclose (with automation) , retrofitment including installation, testing & commissioning of 220 kv circuit breaker relay panel
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required
Tender For supply of arc flash protection relay of masers schneider make having model name vamp 221 , fiber sensor io unit of masers schneider make having model name vam 3l , point sensor io unit of masers schneider make having model name vam 12l , current io unit of masers schneider make having model name vam 4c , point sensor of masers schneider make having model name va1da with the following details - mounting type- surface mount length- 6 mtrs , fibre loop sensor of masers schneider make having model name arc- slm with the following details - length- 50 mtrs
Tender For supply of 33 kv control & relay panel for single transformer (without diffrential protection) , 33 kv control & relay panel for double transformer (without diffrential protection)