Tender For corrigendum : repair/replacement to doors, windows, ventilators, cupboards, internal wiring, summer appliances, hot water appliances, various capacity lt switch gears i.e. mccbs, acbs, contactor, apfc panels, acs and other connected works at af stn 3 wing
Tender For corrigendum : repair maintenance of apfc panels, capacitor banks and connected accessories and other allied works and outdoor worn-out lt panels and connected accessories and other allied works at ins kalinga, ins karna and nad bheemunipatnam, visakhapatnam
Tender For repair/ replacement of lt ug cables alongwith connected items at certain blast pen and repair/ replacement of solar lights ups sps apfc panels voltage stabilizer aviation obstruction lights etc at af stn adampur
Tender For corrigendum : repair/maint/replacement of various capacity lt switch gears i.e mccbs, acbs contactor, apfc panels, ac and other miscellaneous work at af stn nariana under aor of ge (af) faridabad
Tender For supply, installation, testing and commissioning of set of heavy duty capacitor, detuned rea ctor and power factor controller suitable for the maintenance of apfc panels in lhb shed. item not availabl e in gem [ warranty period: 30 months after the date of delivery ]
Tender For supply of electrical works contract c c - complete as per specification no swrccbrccb , supplying erecting and commissioning 2 pole rccb 40a electromagnetic type with 100 ma sensitivity with earth leakage trip indication complete as per specification no swrccbrccb , supplying erecting and commissioning 2 pole rccb 40a electromagnetic type with 300 ma sensitivity with earth leakage trip indication complete as per specification no swrccbrccb , providing and erecting 4 pole mccb 415 v 160a rated shortcircuit breaking capacity 25 ka ics100 of icu adjustable thermal overload setting and fixed magnetic setting with provided leads , providing and erecting 4 pole mccb 415 v 100a rated shortcircuit breaking capacity 25 ka ics100 of icu adjustable thermal overload setting and fixed magnetic setting with provided leads spre , 4 way vtpn sptp og 4p ic mcb db legrand cat no 5077 25 with top and bottom cable end box , 4 way vtpn sptp og 4p ic mccb db legrand cat no 5077 45 with top and bottom cable end box , 6 way vtpn sptp og 4p ic mccb db with top and bottom cable end box , 8 way vtpn sptp og and 4p ic mccb db with top and bottom cable end box , 4 way tpn db having sp og and 4p mcb rccb ic with top and bottom cable end box , supplying and erecting of fabricated 3 phase 1 phase plug and socket tpn db incorporating 63a 4p 100ma rccb as incomer outgoing as 32 amp tp mcb 2 no 20 amp spmcb 4 nos duly erected with , supplying installation testing and commissioning the following as a single vertical compartment of approx 1800mm height as extension to existing panel contractor to survey and measure existing pan , shifting of existing 250 kvar apfc panel from present location to adjacent room along with supply laying and end termination using dc glands of 35 core 240 sq mm al ar cable of 20 meters length , supplying installation testing and commissioning of proposed main panel of new shed as per sld and provided technical specifications , supplying installation testing and commissioning of power distribution panel as per sld and provided technical specifications , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 35 core 300 sq mm aluminium conductor complete erected with glands and lugs on wall , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 4 core 70 sq mm aluminium conductor complete erected with glands and lugs on wall tr , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 4 core 35 sq mm aluminium conductor complete erected with glands and lugs on wall , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 4 core 25 sq mm aluminium conductor complete erected with glands and lugs on wall tru , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 4 core 16 sq mm aluminium conductor , supplying erecting and terminating fr xlpe insulated galvanised steel formed wire armoured strip cable 1100 v 3 core 25 sq mm , 35 core 300 sq mm aluminium , 4 core 70 sq mm aluminium , 4 core 35 sq mm aluminium , 4 core 25 sq mm aluminium , 4 core 16 sq mm aluminium , providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 swg 1.6 mm thick gi sheet of 300mm width and 75mm height , supplying and fixing ms angle and iron supports for cable trays panels dbs etc including painting as per clients recommendation and fixing on wallroof etc , supplying and laying excluding //bid details 2 / 34 excavation reinforced cement concrete pipe of is 4582003 np2 class of 200 mm internal diameter in proper line level and slope including providing and fixing collars i , making trench in hard murumtar road having 075 m depth and minimum 03mtr width as per is for laying provided cables up to voltage level 11kv cable complete as per specification no cwexnctr ,
Tender For corrigendum : 8713 repairs maint of lt panels feeder pillars cables protective system apfc panel lt distribution system and other connected works in new chsc other connected area under age em ii of ge south pune
Tender For corrigendum : repair and maintenance of lt ditribution system feeder pillars under ground cables apfc panels lightening conductors and other em allied work at af arjangarh under ge (af) gurgaon