Web Analytics Made Easy - StatCounter

Relay Panel Tenders

Get complete information related to latest Relay Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40497557 Due date: 04 Jun, 202504 Jun, 2025 1.12 Lacs
Tender For replacement of 1 no 132kv electromechnical double feeder control panel and 1 no 33kv old electromechincal ontrol and relay panel

State Government

CTN :40497442 Due date: 04 Jun, 202504 Jun, 2025 59.3 Thousand
Tender For replacement of protection panel for 100mva 220/132kv transformer at 220kv s/s bharthana and carriage and replacement of 33kv control and relay panel for 33kv feeders at 132kv s/s dibiyapur under etd, etawah.

Central Government And Public Sector

CTN :40330325 Due date: 04 Jun, 202504 Jun, 2025 NA
Tender For corrigendum : supply of ems repair at bsnl oa nadiad - attending fault ea set , attending fauls of ei , laycableupto 35 sq mm , sfixing 5 to 32a spn mcb , sfixing 20a tp mcb , sfixing 63a tpn mcb , sfixing bradided fuel pipe for ea , major overhauling 50 kva ea set , sfixing hosepipe st for50kva ea , rewindingfixing 2hp sub pumpset , sf 10 to 16a relay for pump panel , sf 10 to 16a sp mcb for pump panel , sf push button with element for pump , sf 400 mm wall fan , slaying 3c 2.5sq.mm cu cable as reqd , sf led indi lamps 220 v ac

Central Government And Public Sector

CTN :40477848 Due date: 06 Jun, 202506 Jun, 2025 2.20 Lacs
Tender For supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea

Central Government And Public Sector

CTN :40477607 Due date: 06 Jun, 202506 Jun, 2025 1.14 Lacs
Tender For supply of ea set repair at wtr panwadi te bhavnagar - attending fault easet , bcheckservice of dg set 100 to 160 kva , calibration of fuel pump and nozzle 110kva ea , replacement electronic avr 110 to 250 kva ea , sf 10amp 24v smps battery charger , repair of 12 to 24v starter 100 to 250 kva , sf 12v 110ah mf battery , replace faulty part in ea set v belt , replace faulty part in ea set steel braided fuel pipe , replace faulty part in ea set lub pressure pipe , replace faulty part in ea set starter with with key , replace faulty part in ea set ac ammeter , replace faulty part in ea set pla relay , replace faulty part in ea set brass battery terminal , replace faulty part in ea set 16a hrc fuse , replace faulty part in ea set water hose pipe set , replace faulty part in ea set stop solenoid , replace faulty part in ea set minor joint gasket set , replace faulty part in ea set major joint gasket set , replace faulty part in ea set temp guage , replace faulty part in ea set frequency meter , control panel wiring by authorised service technician , service of engine radiator with chemical wash , repair water pump with service at authorised workshop

State Government

CTN :40075367 Due date: 06 Jun, 202506 Jun, 2025 NA
Tender For corrigendum : 11kv feeder vcbs with cts of ratio 400-200-100/1-1a with control and relay panel (poles filled with nitrogen gas)

Private Sector

CTN :40475140 Due date: 10 Jun, 202510 Jun, 2025 NA
Tender For contract for supply, installation, testing and commissioning of 66 kv control and relay panels at tata power-ddl site.

CTN :40506972 Due date: 09 Jun, 202509 Jun, 2025 1.13 Crore
Tender For supply of routine electrical maintenance of depot , transformer oil testing , installation of acb spares , srvc f inspection and pm of acbs , servicing overhauling and testing f vcb , thermography testing of panel , sply instln lightning arrestor , earthing wire cu 6mm2 , sply and fixg of fuse element rating 11k , earthing clamp , calibration of meter , testing calibration of relay , repair of boom barrier , repair and maint of water pump , testing and servicing pv vent 3in , maint and insp tsvtest and re inst half yrly , sply of 33 kv rubber hand gloves isi app , 11kv rubber hand gloves , silica gel , distilled water battery litres , testing of transformer tan delta , rewinding of motor pump overhauling , electrical insulation mat 2 point 5 mm thick , pvc tape steel grip , crc spray cap 200ml , sply and instln of contactor rat 32a , elcb 30 ma 63 a legrand rating 415v 0 point 0 , elcb 32a 30ma dp w 2nosauxtrpcntct , mcb 415vac 32a 10ka 3p c iec60898 1 , mcb 415vac 63a 10ka 3p c iec60898 1 , hrc fuses for diodes 50a , sply and instln of contactor rat 70a , trip shunt coil acb 110vdc land t , braided wire cu 6mm2 , braided wire strip cu 1in , itc of lugs for 16 sqmm cu , lug ring cu 25mm2 , lamp led indctng 60w rd ylw bl hghmst cg , sup led driver 60w , racking mechanism up acb l and t upower , closing coil shnt trp 110vdc acb 800a , extl safety auditdepot terminal plant , sup and fix of crocodile cliphvydty f earth , contactor dc 110vdc 100a 3p btry chrgr , earthing strip size 50x60x6mm , testing of ht cable meggering and continuity , testing of lt cable meggering and continuity , partial disch testing of cable ht and lt , sply and instln of 2way flp jbtestg and comm , vlf testing of cable , earthing funnel gi , ss nut bolt 1 inch , sup and lay wbmstone aggregate 90 45mm , testing ir and motor tmnl conn yearly , preparation drawingloop diagram layout , autocad drawing retracinglayout conversi bid details/ 2 / 47

CTN :40511221 Due date: 07 Jun, 202507 Jun, 2025 NA
Tender For supply, repair & commissioning of excitation panel , control panel, relay panel of dg set capacity 1750 kw along with replacement of damaged wiring, thruster, exhauster, ampmeter/ volt meter, relay (ol/ef) and other items as required at the time of working. mak e- omron/ae/kaycee or reputed make. [ warranty period: 30 months after the date of delivery ]

CTN :40005205 Due date: 05 Jun, 202505 Jun, 2025 NA
Tender For corrigendum : supply of 33kv feeder vcb 2500a. 31.5ka without cts, control &relay panel (220vdc)
 Loading, Please wait...

Connect us via What's Up