Get complete information related to latest Relay Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Repair Tenders.
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For supply of 49340410s 10 mm wire mesh 1050x91.5 mm , 49340720s 20 mm wire mesh 1250x91.5 mm , d1r00e023 v belt , f1s001026 fastner nylok nut , f1s191027 fastner tension bolt , 500bw0012 conveyor belt for 10mm 22 mtrs , havcon32a contactor 2no 2nc , havcon65a contactor 2no 2nc , 500u40014 gear box , 500bc2a15 high speed coupling , 500bc4a16 low speed coupling , 500cb2a17 coupling bolt with rubber bush , 500cb4a18 coupling bolt with rubber bush , b1sr00297 oil seal for reduction gear box , a1s00i281 gap adjustment seam 05 mm , a1s00i282 gap adjustment seam 10 mm , havolr18a over load relay , havolr40a over load relay
Tender For renovation of electro mechanical items for rural ws scheme, lesliganj - part a (raw water p/plant mali river at sitadih ), cost towards repairing and overhauling of 50 h.p. v.t. pump set multiple stage ball assembly s/f impeller g.m. bush as per sample 5 nos each, s/f housing bush as per sample. replace in spider rubber cutless bush 5 nos, replacing of 25mm dia. 5 feet long s.s. line shaft 4 nos with s.s. socket . transportation charge from site to work shop vice versa including tools tackles and labour charges for lifting & lowering v.t. pump before and after repairing work etc all complete at pumping plant., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots of stator by brush & petrol then complete rewinding of 50 h.p. 440 volts, 50 c/s, star delta, 3 phase hollow shaft v.t. motor by supplying super enameled copper wire & binding, tapping varnishing, heating, testing on full load and repairing of stator & rotor, changing of bearings as per sample skf make with including the deduction of cost of burnt copper wires and transportation charges from p/plant to workshop and back to the same . including tools & tackles and labour charges etc all complete at p/plant., cost towards repairing/ replacement of 200 amp motor control panel board consisting of incoming feeder mccb 200 amp 1 no. and outgoing feeder mccb 100 amp 2 nos, timer 1 no., thermal over load release relay 2 nos. supplying and fitting of digital volt meter (0-500v) squared type 2 nos, ammeter (0-125amp) squared type 2 nos and replacement of phase indicator lamp 3 nos. including internal wiring etc all complete., cost towards supplying & fitting 35 mm2 3 core copper conductor 15 mtr panel to motor., cost towards supplying & fitting 60 watt led street light (jsor-m840), part b (clear water lesliganj.), cost towards repairing/ replacement of 200 amp motor control panel board consisting of incoming feeder mccb 200 amp 1 no. and outgoing feeder mccb 100 amp 3 nos, timer 1 no., thermal over load release relay 3 nos. supplying and fitting of digital volt meter (0-500v) squared type 2 nos, ammeter (0-125amp) squared type 2 nos and replacement of phase indicator lamp 3 nos. including internal wiring etc all complete., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots of stator by brush & petrol then complete rewinding of 20 h.p. 440 volts, 50 c/s, star delta, 3 phase induction motor by supplying super enameled copper wire & then tapping varnishing, heating & testing on full load and repairing of stator & rotor, changing of bearings as per sample skf make with including the deduction of cost of burnt copper wires and transportation charges from p/plant to workshop and back to the same . including tools & tackles and labour charges etc all complete at p/plant., cost for repairing of 20 h.p. c/f pump with m/s/f s.s. shaft as per sample 1 no. c.i. gland tightner 2 nos, c.i. bearing housing 2 nos, ms. check nut 2 nos, c.i. neckring 2 nos, ball bearing s.k.f. as per sample 2 nos, all labour tools & tackles and materials with loading and unloading transporting charge from site to workshop & vice versa., cost towards varnishing, heating of winding & greasing of both side ball bearing of 25 h.p. induction motor 3 phase, 1440 rpm, volt 410 10% 50 cycle along with supplying & fitting of tyre coupling 2 nos, then testing on full load at site including supply of all labour tools and tackles., cost for repairing of 25 h.p. c/f pump with m/s/f s.s. shaft as per sample 1 no. c.i. gland tightner 2 nos, c.i. bearing housing 2 nos, ms. check nut 2 nos, c.i. neckring 2 nos, ball bearing s.k.f. as per sample 2 nos, all labour tools & tackles and materials with loading and unloading transporting charge from site to workshop & vice versa., supplying all labour tools and tackles for complete opening, dismantling , cleaning of its slots o