Web Analytics Made Easy - StatCounter

Relay Set Tenders

Get complete information related to latest Relay Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Set Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45478137 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For corrigendum : items - computer and servises and otheres, mcb (miniature circuit breaker), acb (3200a/4000a ), acb (air circuit breaker), allen key set, amf relay, ammeter, annunciation system, anti-corrosion spray, arc flash suit, arc flash suit (ht/lt panel ), auxiliary contacts, avr (automatic voltage regulator), battery charger, blower/air blower, breather assembly, bus coupler acb, busbar insulators, busbar supports, cable glands, cable glands, cable lugs, cable ties, cable ties, changeover switch, clamp meter, clamp meter, combination pliers, consumables, contact cleaner spray, contactor, continuity tester, control cable, control fuses, control relay, control wires, cooling fan, copper busbar, crimping tool, ct (current transformer), current transformer (ct), dg set synchronization panel (3 750 kva), digital multimeter, digital multimeter, discharge rod, earth fault relay, earth switch, earth tester, earthing rod, electrical contact cleaner, electrical gloves (11 kv rating), electrical safety gloves, emergency stop switch, energy meter, engine control module, face shield, ferrules, ferrules, flexible wire, frequency meter, fuse fuse base, heat shrink sleeves, heat shrink tubes, hrc fuse, hrc fuses, ht protection relay, indicator lamps (r/y/b), infrared thermometer / thermal camera, insulated screwdriver, insulation tape, isolator switch, lightning arrester, load sharing module, lockout-tagout (loto) kit, loto kit, lt pcc/mdb panel, lubricant spray ( ), lugs, maintenance tools, mccb, mccb (molded case circuit breaker), megger (insulation tester), megger 5 kv, microfiber cloth, motorized mechanism, multifunction meter, multifunction meter, nose pliers, numerical protection relay, oti (oil temperature indicator), over current relay, overload relay (olr), phase sequence meter, phase sequence tester, plc module, power analyzer, power cable, power factor meter, protection & metering, pt/vt (potential transformer), push buttons (start/stop), pvc insulation tape, reverse power relay, rust remover, safety equipment, safety goggles, safety helmet, safety helmet, safety shoes, safety shoes, screwdriver set, secondary injection test kit, selector switch, shunt trip coil, side cutter, silica gel, smps (power supply), soft brush, spanner set, speed governor module, spiral wrapping, spring charging motor, starting relay, synchronizing relay, terminal blocks, thermal camera, thermostat, timer relay, torque wrench, transformer buchholz relay, transformer oil, under/over frequency relay, under/over voltage relay, uv coil, vacuum cleaner, vcb (vacuum circuit breaker), voltage tester, voltmeter, wire markers, wire stripper, wti (winding temperature indicator), , , , comprehensive maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor & majour spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete., annual maintenance of substation, transformer, panels, synchronization panel a including all consumables, accessories, minor spares, cleaning materials, testing instruments, preventive maintenance and breakdown maintenance complete.

Central Government/Public Sector

CTN :45329483 Due date: 29 Jun, 202629 Jun, 2026 12.61 Lacs
Tender For corrigendum : provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate nu

corporations/Associations/Others

CTN :45388029 Due date: 22 Jun, 202622 Jun, 2026 6.11 Lacs
Tender For corrigendum : supply of hooter for annunciation system 48v dc 90 110db , screw type indicating bulb 48 50 vdc for annunciation panel , oen relay enclosed dc plugin nominal voltage 48v dc , oen relay , ip converter 4 20ma 24vdc , copper tube pvc insulatd , air filter regulator with pr gauge , k type mi thermocouple duplex type with thermowell , temperature switch

Central Government/Public Sector

CTN :45601623 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For tender for supply of e300 overload relay set, e300overloadrelaysct , e300overloadrelayscm , e300overloadrelaysdem , e300overloadrelaysecm , e300overloadrelayssds

CTN :45609661 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For mb820101 power contactor, 9a, with 1no aux. contact, coil: 230v ac/50hz. , make: siemens (3tf30 10 , mb820102 power contactor, 16a, coil: 230v ac/50hz. , make: siemens (3tf32 00-0ap0) / abb (a16-30- , mb820108 auxiliary contact block, 1no, make: siemens; type: 3tx4 010-2a abb- ca 510 , mb820109 auxiliary contact block, 1nc, make: siemens; type: 3tx4 001-2a abb-ca 501 , mb820305 overload relay, setting: 1.0-1.6/1.4a, make: siemens (3ua50 00-1a) / abb (ta25du 1.40) , mb820308 overload relay, setting: 2.5/2.8-4.0, make: siemens (3ua50 00-1e) / abb (ta25du 4.00) , mb820310 overload relay, setting: 6.3-10.0/6.0- 8.5, make: siemens (3ua50 00-1j) / abb (ta25du 8.50

corporations/Associations/Others

CTN :45601900 Due date: 02 Jul, 202602 Jul, 2026 10.90 Lacs
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k

CTN :45501383 Due date: 15 Jun, 202615 Jun, 2026 14.12 Lacs
Tender For supply of spares for caldyne (now m/s exide industries ltd) make battery charger installed at chp, stps, suratgarh--- avr/acr module for float, type no. 137/3p/fc , avr/acr module for boost, type no. 137/3p/fc , potentiometer 10k ohm/30w , ti 300trip fuse with micro switch , dc uvr/ovr module with card, static type, type no. 69 , dc uvr/ovr card, static type, type no. 69 , fbcor module, static type, type no. 37 , ocr module, static type, type no. 46 , ac sfr module, static type , iprc module, type no. 46 , sfr module, static type, type no. 35 , earth fault relay module, static type, type no. 55 , annunciation module, static type, type no. 62+48+128 , auto equalizing relay card , bleeder network, 1000 ohm/250w

corporations/Associations/Others

CTN :45373601 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For supply of filter capacitor 4700mfd 350v , dcps for idsr statictype 24v dc 12v dc , annunciation card static type 144 128 48 , electronic scr control card for float static type type no. 137 3p fc , surge suppressor static type 251 , snubber network card 0.2mfd 1000v 30ohm 10wtype no.250 , semiconductor protection fuse 450a for battery bank , 2.sm.4.2.10.4 blocking diode 650a 800v , thyristor 340 a 1200 v , relay board 220v dc 3c o , asm pcb idsr138m 140 idsr card static typecard 138m 140 , cell booster 200a

CTN :45195513 Due date: 04 Jun, 202604 Jun, 2026 NA
Tender For corrigendum : supply of voltage operated high speed tripping relay, 3 pole, i. c: - 0099008339 , microprocessor based alarm annunciation system. item code: - 0099008340

CTN :45083875 Due date: 26 May, 202626 May, 2026 35.00 Lacs
Tender For stage contract for supply of key materials required for maintenance of 33/11kv receiving stations along with their lines under the jurisdiction of std bijbehara during the year 2026-27 - electrical store/workshop items/: as per is standards, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (incommer) as per technical specifications of rec std, 11 kv vcb panel board 12 kv, 1250a, 25 ka, outdoor (outgoing) as per technical specifications of rec std, 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type) as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv c&r panel with nemurical relays with out differential relay ( iec 61850), voltmeter, ammeter, annunciation windows with annunciation relays, 3-phase tri-vector meter -5 amps, dlms compliant as per technical specifications of rec std, 33 kv isolator with earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv isolator without earthing blade (36kv,1250a, outdoor, 3 poles, 25 ka), 33 kv outdoor, oil cooled, live tank, single phase , 3 core ct set as per isi specification with accuracy class sp 10 for protection,0.5 for metering & ps for differential with ratio 800-400/5-5-5a ,600-300/5-5-5a , 500-250/5-5-5a, 400-200/5-5-5a (per set of 3 pieces), 33 kv outdoor, oil cooled, copper wound , single phase , pt set with rated primary voltage 33000/ 3 & rated secondary voltage 110/ 3 as per isi specification with accuracy class 0.5 (per set of 3 pieces)., 33 kv lightening arrestors (30 kv, 10ka, station class, zno, porcelain/polymer) gap less(per set of 3 pieces)., 33 kv post insulator (polymer/porcelain 36kv, 170kv impulse), galvanised steel structures(6" g i pipe with top,base & grouting bolts) as per rec, 11kv (e) grade armoured ,almunium,400 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 300 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium,240 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 185 sq mm,3-core,xlpe power cable, (std make), 11kv (e) grade armoured ,almunium, 120 sq mm,3-core,xlpe power cable, (std make), 2.5 sqmm 2 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 4 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 6 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), 2.5 sqmm 8 core control cable armored , copper conductor sheathed pvc insulated multi colour voltage grade 1.1 kv (std make), l t cable 3 1/2 16 sq.mm core armored , al conductor sheathed pvc insulated (std make), 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m or raychem make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 400sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 300sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 240sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 185sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for 3 core xlpe cables, including required size of lugs/thimbles, as per isi specification indoor 120sqmm, 11kv 3 core cable end termination kits of sizes,heat shrinkable of 3m std make required for
 Loading, Please wait...

Connect us via What's Up