Get complete information related to latest Relay Trainer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Trainer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Trainer Tenders.
Tender For supply of heating element 3kw part no_sgsmdlp17a36848-an0010 , heating element 3. 2kw part no_sgsmdlp17a36848-an0011 , heating element 7. 5kw_ part no_sgsmdlp17a36848-an0012 , heating element 9. 6kw_ part no_sgsmdlp17a36848anoo13 , heating coil set 2 ends_ 2 middle_ part no_sgsmdlp17a34957-pht010 , frequency control set_ part no_sgsmdlp17a34955-vpc010 , thermostat_ part no_sgsmdlp17a34958-bs0010 , solenoid assy. _ part no_sgsmdlp17a46077-imc010 , heating coil part assy. _ part no_sgsmdlp17a36155-kmoo10 , temperature control unit_ part no_sgsmdlp17a36155-km0030 , cut off relay unit_ part no_sgsmdlp17a36155-km0040 , water heater_ part no_sgsmdlp17a36293-po0020 , thermostat_ part no_sgsmdlp17a36293-po0050 , heating element 4kw_ part no_sgsmdlp17a36293-hc010 , heating element 13. 2kw_ part no_sgsmdlp17a36293-hc011 , heating element 29kw_ part no_sgsmdlp17a36293-hco12 , heating element 21. 4kw_ part no_sgsmdlp17a36293-hc013 , heating element 10. 5kw_ part no_sgsmdlp17a36293-hc014
Tender For corrigendum : supply of procurement of spares for til make husky 620 cranes of kusmunda ocp d d---- part no. - z7486000093 , trans oil temp. gauge 24v 50150 deg. c, part no. - z7486000094 , fuel gauge 24v 04by4, part no. - z7486000095 , pressure senderswitch-oil, part no. - z7486000103 , temp senderswitch-coolant, part no. - z7486000104 , fuel gauge 24v, 0-1by1, adj, part no. - z7486000178 , kit wiper accessorries, part no. - z7810000001 , toggle switch mom on - off - on mom, part no. - z7872000174 , toggle switch on - off - on mom, part no. - z7872000175 , toggle switch on - none - on, part no. - z7872000176 , toggle switch off - none - on mom, part no. z7872000219 , nylon tube, parker no. tpu 10x1. 5by550, part no. - z7910000198 , wheel cylinder, part no. z9049001328 , brake shoe with lining, part no. z9049001329 , pull spring, part no. - z9049001375 , compression spring, part no. - z9049001376 , switch a2b, part no. - z9352000126 , seal kit for steering cylinder, part no. - z9372005583 , seal kit o-r jack, part no. - z9372005599 , seal kit-suspension, part no. z9372005924 , solenoid, part no. - z9926000965 , solonoide coil 24v, part no. - z9926001058 , solenoid, part no. - z9926000966 , cartridge valve, part no. z9926001461 , seal kit, part no. - z9974000957 , bremstrommel-drum brake assy, part no. z9049001360 , universal joint, part no. - z9049001351 , hoist rope, part no. - x7780000021 , stop light switch, part no. - 334142 , radiator with cac, part no. v7726000045 , seal kit for 15 port hyd. swivel w7364000094, part no. - w7364000094-sk , motor wiper 24v 17w, part no. - z7632000001 , hydraulic oil pressure gauge, part no. - 8341484 , water pipe radiator to engine, part no. - w4131800122 , water pipe -engine to radiator, part no. - w4131800123 , head lamp assy, part no. - z6581000094p , repair kitbrake chamber, part no. - 8312032 , repair kit-system protection valve, part no. - 8312422 , hose kit, part no. - hoskt620 , rear view mirror, part no. - z2162400051 , disc brake pad, part no. - z9904100492db treadle valve , part no. - 7683000069, relay 24v 50 amps, part no. - 7750000058 repl 02309790, relay 24v 20 amps, part no. - 7750000710, nylon pipe 1by4 o-d, part no. - 8308517, dual brake valve, part no. - 8311788, air cylinder, part no. - 8312251, solenoid valve, part no. - 8312280, repair kit, air cyl. , part no. - 8312343, system protection valve, part no. - 8312375, wiper arm & blade pantograph, part no. - 8315281, solenoid valve, part no. - 8340241, m. c. assy. -bi-64068447 08, part no. - 8340369, sheave, part no. - 8985576, u joint, part no. - 9364101867, fan belt, part no. - f0t00800, transmission shifter-4speed, part no. - u7872000197, floating sheave, part no. - v6718000011, nylatron sheave, part no. - v6718000012, o/r jack, part no. v7372000195, gear pump - 24 c. c. , part no. v7722000110, engine stop solenoid, part no. x3992400, solenoid engine stop, part no. x7009000019, vibrosonic horn ht -24v, part no. x7025000017, reverse buzzer, part no. - x7025000019, sheave bearing, part no. - x7086000031, fuse holder in line blade type, part no. - x7482000040, oil level and temp. gauge, part no. - x7486000086, ignition switch, part no. - x7872000051, switch - head - side lamp, part no. - x7872000097, limit switch, part no. x7872000178, temperature switch, part no. x7872000189, battery disconnect switch, part no. x7872000192, cvmc assembly, part no. - z2162400025, //bid details2 / 75
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi
Tender For supply and fitting of bucholz relay,winding temperature indicator and oil temperature indicator for 4nos. of 1000kva transformer,sl.no.ve10001/06, ve10001/07,ve10001/09 and prm1210142 with complete control panel,necessary relays and tripping circuit