Web Analytics Made Easy - StatCounter

Relay Trainer Tenders

Get complete information related to latest Relay Trainer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Trainer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Trainer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43521521 Due date: 30 Jan, 202630 Jan, 2026 NA
Tender For supply of main contator , pt , overload relay thermal, 16-25 a , aux. contact coil voltage , relay, time delay, pnmtc timer,

Central Government/Public Sector

CTN :43497214 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For abb make lt switchgear spares for st2 ntpc simhadri - contactor: ac/dc operated,110v,18a,3p, contactor: ac/dc operated,110v,305a,3p, contactor: ac/dc operated,110v,80a,3p, contactor: ac/dc operated,110v,265a,3p, contactor: ac/dc operated,110v,205a,3p, contactor: ac/dc operated,110v,146a,3p, contactor: ac/dc operated,110v,32a,3p, contactor: ac/dc operated,110v,116a,3p, contactor: ac/dc operated,110v,65a,3p, relay: therm o/l,0.41-0.55a,tf42,abb, relay: therm o/l,0.55-0.74a,tf42,abb, relay: therm o/l,0.74-1.0a,tf42,abb, relay: therm o/l,1.30-1.70a,tf42,abb, relay: therm o/l,1.70-2.30a,tf42,abb, relay: therm o/l,2.30-3.10a,tf42,abb, relay: therm o/l,4.20-5.70a,tf42,abb, relay: therm o/l,5.70-7.60a,tf42,abb, relay: therm o/l,7.60-10.0a,tf42,abb, relay: therm o/l,10.0-13.0a,tf42,abb, relay: therm o/l,13.0-16.0a,tf42,abb, relay: therm o/l,16.0-20.0a,tf42,abb, relay: therm o/l,20.0-24.0a,tf42,abb, relay: therm o/l,24.0-29.0a,tf42,abb, relay: therm o/l,29.0-35.0a,tf42,abb, relay: therm o/l,35.0-40.0a,tf42,abb, relay,thermal o/l,3-5a,ta25du5.0m,abb, relay,thermal o/l,7.5-11a,ta25du11m,abb, thermal olr,1saz211201r2023,abb, thermal olr,abb,ta25du2.4m, thermal olr,abb,ta25du 4.0m, relay: o/l cur,4.5-6.5amp,440v, relay: thermal overload,13-19a,abb, relay,thermal o/l,18-25a,ta25du25m,abb, thermal olr,abb,ta75du42m, relay: thermal olr,45.0- 63.0a,ta80du63m, switch fuse unit,os400d03p,abb, switch fuse unit,os250d03p,abb,250a, switch fuse unit,os125gd03p,abb, switch fuse unit,os63gd04n2p,abb, switch fuse unit,os32gd04n2p,abb, contactor,auxiliary,110vac,4no,abb, contactor,auxiliary,250vdc,2no+2nc,abb, aux contact block,ca4-10,abb, aux contact block,ca4-01,abb, aux contact block,cal4-11,abb, aux contact block,cal19-11,abb, aux contact block,cal19-11b,abb, closing coil,sps0000062,ge,acb,s800-2500, charging motor,sps0000033mks,ge,s3200, shunt trip coil,sga0100039,acb

State Government

CTN :43473704 Due date: 28 Jan, 202628 Jan, 2026 NA
Tender For supply of siemens make switchgears for coal handling plant at wtps - 630 a molded case circuit breaker with etu 330 protection , type : 3va2463-6hm32-0aa0, 250 a molded case circuit breaker with etu 330 protection , type : 3va2225-5hm32-0aa0, 63 a molded case circuit breaker with etu 330 protection , type : 3va2063-5hm32-0aa0, door mounted rotary operator as standard with plastic handle 8uc ip65 for india, accessory for: 3va13/14; 3va23/24 ; mlfb : 3va9467-0fk51, door mounted rotary operator as standard with plastic handle 8uc ip65 for india, accessory for: 3va20/21/22 ; mlfb : 3va9267-0fk51, auxiliary switch changeover contacts type hq (7 mm) accessory for: 3va1; 3va20-26 ; mlfb : 3va9988-0aa12, trip alarm switch changeover contacts type hq (7 mm) accessory for: 3va1; 3va20-26 ; mlfb : 3va9988-0ab12, bus connectors broadened front mounted; 4 units extended pole-center distance for india, accessory for : 3va 20-26 ; mlfb : 3va9484- 0qc50, bus connectors broadened front mounted; 3 units accessory for: 3va20/21/22 ; mlfb : 3va9263-0qc50, bus connectors broadened front mounted; 3 units extended pole-center distance for india ; mlfb : 3va9153- 0qc50, siemens make mccb 4-pole 100a breaking capacity 25ka at 415v, 50hz, siemens make mccb 4-pole 125a breaking capacity 25ka at 415v, 50hz, siemens make, sicop bimetal overload relay, range : 12.5-20amp, type :3ua5500-2b, sicop bi metal relay , type 3ua5800-2cz1 range: 16-25 a, bimetal over load relay 3ua58002ezi siemens make 25.0 - 40.0a range, siemens make bi-metal overload relay range 40 to 57a reference no. 3ua5800-2tz2, bimetal relay,make-siemens,range-57.0 -70.0 amp type-3ua58 00-2vz1, siemens make, sicop bimetal overload relay, range : 63-80amp, type :3ua5800-2u22, over load relay, rating: 80 a - 110 a, model: 3ua60, make: siemens, siemens make bi-metal overload relay range 115 to 180a cat. no.:-3ua6230-5b, thermal overload bimetalic relay, range:160-250a, type-3ua6230-5c, indepedant mounting, siemens make, siemens make microprocessor based overload relay current range 50 to 200a and size s6, accessories for sicop bimetal relays for independent mounting for relay type :3ua58, type :3ux1421, accessory for independent mounting of siemens make 3ua52 bimetal overload relay

CTN :43484362 Due date: 19 Jan, 202619 Jan, 2026 NA
Tender For supply of plug x 19 , fuse box , fuse 2a , relay thermal overload

CTN :43448164 Due date: 27 Jan, 202627 Jan, 2026 NA
Tender For supply of electrical and rac items under capstone project of mechanical department at dr. b. r. ambedkar institute of technology (dbrait), sri vijaya puram - supply of electrical & rac items under capstone project, sliding gate motor with rack and pinion(power supply: ac 220v-240v ac, output torque: 27 n-m,motor speed: 1440 rpm, gate speed: 12 m /minute, maxgate weight: 1000 kg, noise: 56 db, limiting switch: springlimit switch, transmitter distance: 50 m, working cycle: 40%, ip class: ip44, operator: ac operator including controlboard, base plate and magnetic limit., remote control: 1 pair(2 nos.), transmitter 4 channels. photo cell: 1 pair (2 nos.)with input power: ac/dc 12-24v, detecting distance max: 15m, ip class: ip55., metal rack: 1 meter rack x 10 nos.,thickness: 09 mm. warranty: 01 year, pinion: 1 extra pinion), power supply cable(4 sq mm, 2 core, pvc insulated), open well submersible pump(5 hp, 65x65, suction / delivery, head range: 30-50 m, rpm: 2800, three phase, voltage: 415v, power rating - 7.3 kw, make: lubi/kirloskar/groundfos), rgb fountain light(s.s body, ip 68, waterproof, output cable length minimum 2 meter, 27 watt. with smps & controller), dol starter(5 hp, 3 phase, 415 v), solenoid valve(waterproof, ip68, s.s body, grade: 304, thread type, size: 1.5 inch, pressure range: 0.5-12 bar, operating voltage: 24 dc, solenoid valve(waterproof, ip68, s.s body, grade: 304, thread type, size: 1 inch, pressure range: 0.5-12 bar, operating voltage: 24 dc), dc smps(10 ampere, 24 volt), arduino- uno r3 board(standard), adapter(5v, 2 amps), relay module(6 output), compressor -r134 a(model name/number: cj513, motor power: 1 hp, capacity: 1 ton, phase : single phase), copper tube(diameter: 1/4 inch, length:15m), high pressure gauge(type: bourdons tube, dial size: 65mm, range: 0-550 psi, connection type:back mounted connection, glycerin filled, thread connection size:1/4 inch, end connection: male), low pressure gauge(type: bourdon s tube, dial size: 65mm, range: 0-550 psi,connection type: back mounted connection, glycerin filled,thread connection size :1/4 inch, end connection: male), digital ammeter(input signal: ac, range: 0-20 amps, supply: 230 v ac ), digital voltmeter(model: smp355, range: 0-300 v ac, display: 0-300 v ac, accclass 0.5, aux: 230 v ac), lp/hp cut out(model: type mp15, pressure range: low side: vacuum up to100 psi (-30 in hg to +100 psi), high side : 0 to 85 psi(approx.), adjustable differential : 0.6 to 7 kg/cm (approx. 9to100 psi) ), temperature indicator (nutronics auto scanner dtim-200m)(sensor input : pt-100, range: 200 degree celsius, supply :230 v ac with selector switch ( 0 - 9 ), refrigerant: freon r 134 a(450g, can), copper brazing rod(thickness - 2 mm), copper brazing rod(thickness - 3 mm), white brazing flux powder(standard, for copper), lpg (can)(225 ml ), capillary tube(internal diameter: 0.5 mm, material: copper), suction accumulator for r134 a(0.5 inch), liquid line filter drier(1/4 inch), capacitor(4 mfd), refrigeration shut off valve(diaphragm hand valve, size: 1/4 inch), wire(2.5 square mm, copper ), refrigerator thermostat(type : rotary adjustable thermostat, control range :1-9temperature range : 5 c to +10 c, power : 220 240 v ac,50 hz,), thermal insulation sleeve(length: 1 meter , inner diameter: 10 mm ), thermal insulation sleeve(length: 1 meter , inner diameter: 15 mm ), electrical insulation tape(standard ), condenser (heat exchanger)(condenser tube outer dia. : 3/8 inch, for 1 hp capacity , r-134a compatible), thermocouple with wire(temperature sensor rtd, pt-100, od: 6mm, length: 4 inch or100 mm)

Central Government And Public Sector

CTN :43445684 Due date: 09 Jan, 202609 Jan, 2026 NA
Tender For 1. solid state over voltage relay for transformer rectifier unit of rmpu coaches. specn: specification no: drg. icf specification n0,icf/elect/897 rev.o or latest.;2. insulation monitoring relay 110 volt ac, range 50 v to 200 v ac insulation measuring range 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 hz having fault memory test and reset button and alarm lead as per rcf specification edts-073 rev d amend 3. as per drg.no. nil specn: rcf specification edts-073 rev d amend 3;3. mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0)4. set of thermal expansion valve suitable for lhb rmpu ac unit of 3.5 ton-conforming to rdso spec:-rdso/pe/spec/ac/0061-2005(rev.-1) one set contains two valve. 1] sporlan-ebve :7/8

State Government

CTN :43411270 Due date: 28 Jan, 202628 Jan, 2026 NA
Tender For supply of thermal over load relay with 3 phase contactorrang- 3a to 6amake- siemens/havels/schnieder

State Government

CTN :43365060 Due date: 13 Jan, 202613 Jan, 2026 10.00 Lacs
Tender For annual rate contract for work of supply and fixing of various electric spare parts for starter and panel ci specials sluice valve nrvs of various uwss city sardarshahar under phed div sardarshahar - 261400 supply and fixing of oil / air break dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors.261420 fully automatic star/ delta starter261424 30.0 hp to 35.0 hp, 261400 supply and fixing of oil / air break dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors. fully automatic star/ delta starter261423 20.0 hp to 25.0 hp, 100700 p&f 240/415 v porcelain kitkat fuse (/hbc type) conforming to is:2086,1983 0n existing board/ sheet including making connections with lugs, testing etc. as required100706 100 a ,415 v100706.2 group - 1, 080300 sf of (0-500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080301 analog type ( 96 mm x 96 mm )080301.2 group - 1, 080400 sf of ct operated direct reading type ampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080410 analog type ( 96 mm x 96 mm )080411 below 500 a080411.2 group - 1, 080600 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc. as required .080600.2 group - 1, 080800 sf of 110/220 v, led (22.5 mm dia ) indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 blue colour080802.2 group - 1, 081400 p & f cam operated rotary switches on existing panel with 2 way and off position081410 one pole081412 32 a081412.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.3 group - 2, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081516 70 amp081516.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 amp081702.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 amp081703.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 amp081704.2 group - 1, 082000 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming etc. as required082002 one day & week reserve (mechanical type )082002.2 group - 1, 090600 sitc of quick make and q

Central Government/Public Sector

CTN :43379059 Due date: 09 Jan, 202609 Jan, 2026 37.77 Lacs
Tender For supply of procurement of spares prabhu make flp lt ht starter dp and geb d d ? g? g - contactor complete 400 amps. 3. 3kv, part no. ht-200 , vacuum contactor rectifier bridge, part no. ht-201 , bottle for vacuum contactor 3. 3kv, 400 amps, part no. ht-202 , vacuum contactor closing coil 110v dc, part no. ht-203 , vacuum contactor holding coil 110v dc, part no. ht-204 , auxiliary switch for vacuum contactor 2no 2 nc, part no. ht-205 , p. t. 40va 0-8-12v 0-110v, part no. ht-206 , auxilary contactor 3 no 1 nc 110v ac, part no. ht-208 , resin cast p. t. 750va 3. 3kv 110 volts single phase, part no. ht-300 , h. t control fuse 3. 3kv, 2 amps, part no. ht400 , copper busbar 400amps set of three, part no. ht-101 , resin cast moulded c. t. for o l 3. 3kv, part no. ht-600 , dmc moulded 3. 3kv insulator for power fuse, part no. ht700 , push button with element for start, stop, test and reset, part no. ht--1300 , lamp holder with lamp for starter, part no. ht-1400 , brass cable gland complete with c. i clamp, stud , part no. ht-1600 , s t idmtl o c and s c r with time leg o l setting - 50 percent to 200 percent and s c setting 400 percent to 1600percent of flc, part no. ht-900a , e. l unit complete without transformer, part no. ht-800 , dmc moulded copper terminal 400a, 3. 3kv , part no. flp vcb 045 , isolator 100 amps reversing, part no. fs- 2 002 , air break contactor 40amps upto 20hp 550v starter, part no. fs- 2 003c , air break contactor 63amps upto 30hp 550v starter, part no. fs- 2 003e , auxiliary transformer 80va pri-500 525 550v sec-0-8-12, 0-110v, part no. fs- 2 004c , dmc terminal for i c ,t g,o g and partition 100 amps, part no. fs- 2 008 , dmc auxilary terminal, part fs2 009 , 3 pole magnetic o l relay type direct acting, part fs- 2 010 , direct acting thermal overload relay upto 30hp starter, part no. fs-2 010a , 65 sq mm ammeter ct operated, part no. fs-2 011 , 65 sq mm ammeter direct acting, part no. fs-2 011a , ct for ammeter, part no. fs-2 012 , short circuit hrc fuses 63 amps, part no. fs- 2 014e , auxilary contactor 2 no 2 nc 110v 415v 500v, part no. fs- 2 020 , pilot relay 12v dc, part no. fs- 2 026 , s e l r with cbct and p. t. el setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire, part no. fs- 2 037 , isolator 200 amps reversing, part no. fs- 3 002b , isolator 300 amps reversing, part no. fs- 3 002c , air break contactor 185amps, fs- 3 003h , air break contactor 300amps, fs- 3 003l , air break contactor 325 330amps, fs- 3 003m , dmc terminal for i c and t g 300 amps, fs- 3 008a , dmc terminal for i c and t g 400 amps, fs- 3 008b , dmc terminal for outgoing partition 300 amps, fs- 3 009b , dmc auxilary terminal, fs- 3 010 , 3 pole magnetic o l relay type ct operated, part fs- 3 011a , ct operated thermal overload relay 4. 5 to 7. 5a with mounting kit, fs-3 011c , ct for overload relay,fs- 3 012 , 65 72 sq mm ammeter ct operated,fs- 3 012b , 65 or 72 sq mm voltmeter 0-600v, fs- 3 012d , pilot relay 12v dc, part no. fs- 3 026 , s e l r with cbct and p. t. e l setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire,part no. fs- 3 041 25 amps contactor with 110v coil, part no. dpf-1 002a, hrc fuse base with carrier, part no. dpf-1 004, hrc fuse link,10 amps, part no. dpf-1 004a, e l. trip indication lamp, part no. dpf-1 006a, glass fuse. 1 amp, part no. dpf-1 007a, glass fuse. 2 amps, part no. dpf-1 007b, on off toggle switch, part no. dpf-1 008, incoming throughgoing dmc,moulded terminal with brass stud, part no. dpf-1 013, interconnecting dmc, moulded terminal with brass, part no. dpf-1 013a, condensor,16v,220 mfd. , part no. dpf-1 019, m 8 //bid details2 / 59

CTN :43380005 Due date: 20 Jan, 202620 Jan, 2026 NA
Tender For tender for supply of 25bz6c001 primary and secondary switchboard d d -rail 12 modules hl105 , rail 22 module hl105 , module hl105 9x2 contacts awg20 , module hl105 3x6 contacts awg20 , module hl105 1x10 contacts awg16 , fan 28vdc 23w , voltage transformer 3ph 115 24.5v 60hz 1.5kva , voltage transformer 3ph 115 24.5v 60hz 1kva , diode terminal block with 1n4007 , relay 2rt 2a 28vcc p , relay 2rt 2a 28vcc p , relay 2rt 2a 28vdc with suppressed device , relay 2rt 10a 28vcc , timer on operate 28vdc 5-100 sec , isom , torus d80mm , specification ci shunt , connector sup 6 slot , module 4 di pnp 2 3 4 connections 24 v dc , simatic dp , 5 universal terminal modules tm-e15c26-a1 , 5 shield connecting elements terminal modules tm-p and tm-e , fus 1a type ha22 , feeder terminal to 25sqmm for 10x3mm and 6x6mm n-busbar , bla , soldered base 2rt 2a 28vcc (p) , base weld , dc circuit breaker nsx630 mp3 without socle , voltmeter 72x72 250% cl 1.5-0 600vdc , frequency meter 72x72 250 cl 1.5 55 65hz , meter phase 72x72 250 cl 1.5 cph t3fe-0.5 cap 0.2 ind , voltmeter 72x72 250% cl 1.5-0 150vdc , ac circuit breaker nsx250 without socle , ac circuit breaker nsx250 without socle , analog threshold detector mcr-sws u 0-10v , fus 0 , 63a rapide 6.3x32 ha37 , numeric indicator , card 1 2atr 12 relais 2rt 2a 28vdc , douille type 40r , fus 1 , 6a 6.3x32 ha37 , fuse 14x51 690v 60hz 6a gc , isolator m8 , head pb d22 green , push button 2f black , switch 4 positions 2 stages , switch 4 pistons 2 stage , switch 2 positions 8 stages , thermal protection td04 , switch 2 pos , switch 2 pistons 6 stage , voltmeter switch , nsx630-mn coil , dc circuit breaker nsx250 tm125 without socle , fuse holder 14x51 type cms142 2p 440v 60hz 16 am , current tranformer 500 5a 10va cl-0-5 , current tranformer 500 5a 10va cl-0-5 , crimp base 1rt 25a 28vcc p , fuse holder 14x51 type cms143 3p , spare part to replace all of the varistors in a motor rack , rectifier diode modules 100a , mechanical push button red , fus 8a am 14-8mr 690v 6% , fuse 14x51 690v 60hz 2a gg , signal lamp unit d16 28vdc blue , signal lamp unit d16 28vdc white , fus 2 , 5a type ha22
 Loading, Please wait...

Connect us via What's Up