Get complete information related to latest Relief Valve Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relief Valve Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relief Valve Repair Tenders.
Tender For supply of nitrogen gas cylinder capacity 50l, 200 bar with pressure gauge fitted with fire rated automatic fire suppression activation solenoid valve with manual override lever duty fitted with nitrogen at 200 bar + or -10% as per attached specification.
Tender For supply of ship equipment tools c c - marine air compressor reciprocating with special tools , marine waste oil incinerator , marine fresh water generator , centrifugal filter fitted on generator auxiliary engine , pressure calibration kit , temperature calibration kit , protable multiage detector , personal gas detector , peak pressure indicator , indicator instrument , inert gas o2 analyzer with n2 cylinder , smc engine exhaust valve complete , piston for smc engine with stuffing box , injector test unit for 2 stroke main engine complete with all connections and injector , 350mc manual set , yanmar daihatsu manual set , prop drop guage , cylinder head complete with mountings , preservation packing transportation and unloading at the workshop to be done by the vendor
Tender For corrigendum : supply of procurement of various types of spares for gse at amd and bom d d-- sensor, inductive 10-36v, 250ma , valve ,c,balance 3-1 2800 , seal kit,sun cavity t-2a , bridge lift cylinder seal kit , flap- engine , gas spring , drive shaft lg 540 , asd handrail prox,mov.assy
Tender For supply of angle head nut for hmp make cutting torch , o ring for plug hmp make cutting torch spares , o ring for rock nut hmp make cutting torch spares , o ring for seal nut hmp make cutting torch spares , cylinder nut hmp make da gas regulator spares , cylinder nut hmp make oxygen gas regulator spares , cylinder nut hmp make argon gas regulator spares , 1st stage moulded pin valve hmp make da gas regulator spares , second stage moulded pin valve hmp make da gas regulator spares , 1st stage moulded pin valve hmp make oxygen gas regulator spares , second stage moulded pin valve hmp make oxygen gas regulator spares , 1st stage moulded pin valve hmp make argon gas regulator spares , second stage moulded pin valve hmp make argon gas regulator spares , 1st stage moulded pin valve hmp make co2 gas regulator spares , second stage moulded pin valve hmp make co2 gas regulator spares , diaphragm small hmp make da gas regulator spares , diaphragm big hmp make da gas regulator spares , diaphragm small hmp make oxygen gas regulator spares , diaphragm big hmp make oxygen gas regulator spares , diaphragm small hmp make argon gas regulator spares , diaphragm big hmp make argon gas regulator spares , diaphragm small hmp make co2 gas regulator spares , diaphragm big hmp make co2 gas regulator spares , safety valve for hmp make da regulator , safety valve for hmp make oxygen regulator , safety valve for hmp make ar regulator , safety valve for hmp make co2 regulator
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode