Tender For mtc.of rws/pdf/15 fc/other panchayat/deposit fund schemes in north tripura 26-27/sh-providing, fixing in/c repair of electrical panel board comprising with starter main switch, motor protection device of panisagar block of dws sub-division, panisagar
Tender For district child protection unit, collectorate bhagalpur :- - district child protection unit, collectorate bhagalpur :-regarding the publication of an advertisement to enlist ‘support personnel’ (for the purpose of forming a panel).
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset controlpanel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For replacement of carrier protection panel for channel-i at both kharagpur (wbsetcl) and baripada (pgcil) end i.r.o. kharagpur- baripada 400 kv single circuit transmission line and allied work on turnkey basis
Tender For corrigendum : tender for supply of solar pv panel topcon - 15 kw , grid connected inverter/ power conditioning unit (pcu) alongwith built-in meter , module mounting structure (mms) , structure accessories , net meter and solar meter , array junction box , dcdb , acdb , string and jumper , earthing and cable , lighting arrestors , lighting protection system (lps) , surge protection device (spds)- surge arrestor , connectors , conduits and pipes. , dc cable for string and jumper , power cable from inverter to acdb , power cable for earthing - 15 kw , ac armored aluminum cable - 15 kw , installation , testing and commissioning - 15 kw , grid islanding protection as per nit , danger boards & signages as per nit , fire extinguishers as per nit
Tender For corrigendum : purchase of equipments for dmt department lab - purchase of equipments for dmt department lab, fanuc cnc simulation trainer kit system type: standalone cnc simulation trainer with integrated hardware panel functionality: switchable milling (3-axis) and turning (2-axis) simulation cnc control: original fanuc control system or officially licensed equivalent software: manual guide i (licensed version) for conversational programming and 3d simulation programming: supports g code (iso standard) and conversational programming storage: minimum 512 kb program storage with at least 400 programs tool offsets: minimum 32 pairs coordinate system: g52 g59 with minimum 48 additional work offsets (milling) display: minimum 10 color lcd input: full qwerty keyboard connectivity: usb, ethernet interfaces: rs232 / i/o link power supply: 100 240 v ac, 50 60 hz power consumption: 100 w construction: industrial grade trainer unit , robotic arm controllerdegrees of freedom: 6 dof payload: minimum 250 g at full reach reach: minimum 350 mm repeatability: 0.2 mm or better controller: industrial-grade controller (arm cortex-m4 or higher / equivalent architecture) programming: supports gui based and programming (python / c++ / equivalent) vision system: integrated camera with ai-based object detection capability communication: usb and serial communication software: licensed software compatible with windows os end effectors: minimum 3 (gripper, suction cup, pen holder) safety: emergency stop, limit protection power supply: 100 240 v ac, 50 60 hz, optical digital microscopemagnification: 40x to 400x digital camera: minimum 5 mp resolution display: pc/monitor via usb/hdmi or built-in display illumination: adjustable led illumination focus: coarse and fine focusing mechanism optics: coated lenses with wide field view stage: mechanical stage with slide holder software: image capture, measurement, and analysis software included connectivity: usb / hdmi /ethernet power supply: 110 240 v ac, 50 hz, portable surface roughness tester parameters: ra, rz, rq, rt measuring range: ra: 0.005 16 m rz: 0.02 200 m resolution: 0.01 m accuracy: 5% or better stylus: diamond tip ( 5 m radius) cut-off lengths: 0.25 mm, 0.8 mm, 2.5 mm display: digital lcd output: usb interface for pc connection standards: iso 4287 / din / ansi compliant power: rechargeable battery
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto
Tender For supply cable 70 sqmm x 3 point 5 core alumunium , supply 16 sqmm x 3 point 5 core alumunium , supply 1 point 5 sqmm x 3 point 5 core copper , supply 4 sqmm x 3 point 5 core copper , supply 2 point 5 sqmm x 3 point 5 core copper , supply 25 sqmm x 3 point 5 core alumunium , supply 35 sqmm x 3 point 5 core alumunium , sitc distribution box panel flp , sitc distribution box non flp having contactor and emergency shut down buttom , sitc distribution box llight panel flp , sitc distribution box panel light non flp , sitc dol starter 5 hp , sitc dol starter 2 hp , sitc dol starter 3 hp , sitc dol starter 10 hp , sitc flp dol starter 5 hp , cable glands non flp for 70 sqmm cable , cable glands non flp for 35 sqmm cable , cable glands non flp for 25 sqmm cable , cable glands non flp for 4 sqmm cable , cable glands non flp for 2 point 5 sqmm cable , cable glands non flp for 1 point 5 sqmm cable , cable glands flp double compression for 16 sqmm cable , cable glands flp double compression for 4 sqmm cable , cable glands flp double compression for 2 point 5 sqmm cable , cable glands flp double compression for 1 point 5 sqmm cable , cable laying and and as per detailed specification of tender attachments , cable glanding , connections, terminations , excavation for cable laying , sitc of well glass led lights 90 watts flameproof complete set with drivers etc , sitc of non flp normal under roof led lights 90 watts flameproof complete set with drivers etc , rubber mats 1 m wide , earrthing strips supply and laying 50 mm x 2 point 5 mm , earrthing strips supply and laying 25 mm x 2 point 5 mm , earthing pits , sitc street light pole , sitc flp street light , sitc flp juction box for light , sitc double arm for street light , civil foundation , foundation bolt set for light pole , cable route and joint markers , sitc flp emergency light 45 w , sitc non flp emgency light , sup point earthing cable 1c x 6 sqmm , sup point earthing cable 1c x 10 sqmm , ms structure steel , supply and lay b class gi pipe for cable protection , sitc 4 way junction box , cable tray 100mm x 50mm gi supply , cable tray 50mm x 25mm gi supply , cable clamps , flp blind plug 3 by 4 inch , preparation of earthpit and cable route drawing
Tender For corrigendum : providing of design installation and maintenance of educational lab/centre - smart class lab; site preparation, supply and installation of hardware, teacher training, maintenance of hardware (amc/cmc); buyer - interactive flat panel display , ups , camera with microphone , end point protection (anti-virus) for ops , device management software for both ifp & ops , central project monitoring dashboard , wall mounted cabinet for safety protection