Tender For selection of solar power generators (spgs) on the basis of build own & operate (boo) for design, survey, supply, installation, testing, commissioning, operation & maintenance of grid connected distributed solar power plants for solarization of selected 33nos agriculture feeders at 8nos of sub-station(ss) level with capacity of 34.43mw in gescom jurisdiction totally covering 11756 nos of ip sets and its associated 11kv line to connect the plant with concerned sub station(ss) and remotemonitoringsystem (rms) of solar power plants through resco mode, for 25 years under component c - feeder level solarization of pm-kusum scheme
Tender For supply, installation, testing & commissioning of da set 500kva (336kw), 750v, 3p hase diesel alternator set, cpcb-iv complaint for lhb power car (without power and cont rol panel) conforming to rdso/pe/spec/ac/0084-2008 rev-1, with rcf annex.-a and icf amendm ent-1 along with manual isolating switch as per edml-208, and remotemonitoringsystem a s per mcf/rbl medts-0006, rev-0. the da set shall be with noise reduction features (withou t acoustic panels) as per spec. no. rdso/pe/ms/ac/0045-2008 rev-0, amdt-1 with rcf annex-c. [ warranty period: 30 months after the date of delivery ]
Tender For selection of solar power generators (spgs) on the basis of build own & operate (boo) for design, survey, supply, installation, testing, commissioning, operation & maintenance of grid connected distributed solar power plants for solarization of selected agri feeders at sub-station (ss) level in cesc jurisdiction totally covering ip sets, its associated 11kv line to connect the plant with concerned ss and remotemonitoringsystem (rms) of solar power plants through resco mode, for 25 years under component c-feeder level solarization of pm-kusum scheme
Tender For supply of urine monitoring device , modular dilysis unit on turnkey basis , water filtration plant on tyrnkey basis at mira bhaynder , fully automated processor for gel cards , chemiluminescence immunoassay machine for blood bank , blood storage refrigerator 2 to 6 , domestic fridge 365 liter , deep fridge , tube sealer machine , ophthalmoscope , diathermy bipolar , blood gas analizer , c arm machine , non contact tonometer , ophthalmic microscope , phaco machine
Tender For corrigendum : design, engineering, procurement supply, construction erection, testing, commissioning of solar power plants, associated 33 kv or 11 kv line and remotemonitoringsystem (rms) and comprehensive om for 5 years of grid connected ground mounted sol
Tender For corrigendum : purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing systemsystem should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-a
Tender For design, supply, installation, testing, commissioning with remotemonitoringsystem with comprehensive warranty, guarantee for 5 years and operation and maintenance of the complete plant for 5 years from commissioning date for the grid connected, establishment of 0.75mw(ac) capacity ground mounted solar photo voltaic power plant at 33/11kv sub-station dhantalapally in mahabubabad (dist) of tgnpdcl as required on 100% turnkey and build, operate, maintain and transfer (bomt) basis in tgnpdcl