Get complete information related to latest Repeater Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Repeater Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Repeater Panel Tenders.
Tender For corrigendum : repair/maint and improvement of lt distribution network, lt panel, fp box and other allied works in sector c and sector d md accn in army area under ge (a) no.1 jodhpur
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For corrigendum : provision of noise reduction paneling for motivation hall, operation room and 05 in nos air conditioner for admin offices and special repair of main distribution panel associated with power distribution at icgs mayabunder, under ge(s) diglipur.
Tender For supply of repair station for nsc rdr , electrostatic mat , shielded metal arc welding electrode , mild steel filler road 4mm x 450mm , ferrous metal repair electrode , flexible power transmission cable , flood light , copper conductor pvc insulated cable , modular power distribution panel
Tender For supply of sitc control panel 2 loops , sitc control panel 4 loops , sitc of network module the module shall connect panels , sitc of active repeaterpanel to be integrated with fire alarm , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitcof addressable multi sensor with co detection , sitcc of response indicator on surface or recessed , sitc of short circuit isolator module base with all mounting , sitc of analogue addressable dual action , sitc of addressable horn with a maximum output of up to 100 db a , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls , complete earthing electrode and excavation etc , earth continuity conductor , false ceiling board and cross tee , butterfly valves (v2) as per is 13095 (q2) * /bid number : gem/2026/b/7624747 + /dated: 27-06-2026 ' ' / bid document 1 / 20
Tender For supply of sitc control panel 2 loops , sitc control panel 4 loops , sitc of network module the module shall connect panels , sitc of active repeaterpanel to be integrated with fire alarm , sitc of addressable ip67 rated multi- heat sensor , sitc of analogue addressable photo thermal smoke detector , sitcof addressable multi sensor with co detection , sitcc of response indicator on surface or recessed , sitc of short circuit isolator module base with all mounting , sitc of analogue addressable dual action , sitc of addressable horn with a maximum output of up to 100 db a , sitc of analogue addressable supervised monitor module , sitc of analogue addressable supervised control module , supplying and laying through walls , complete earthing electrode and excavation etc , earth continuity conductor , false ceiling board and cross tee , butterfly valves (v2) as per is 13095 (q2) * /bid number : gem/2026/b/7624664 + /dated: 27-06-2026 ' ' / bid document 1 / 25
Tender For supply of detector removal tool as per atc , loop card micro module as per atc , serial esser net interface modules as per atc , network card essernet series 2 nw card 64 k as per atc , main fire alarm control panels cpu card for facp as per atc , iq8 repeaterpanel as per atc , heat detector as per atc , otg multisensor fire detector co iq8quad with isolator as per atc , o2t multisensor fire detector iq8quad with isolator as per atc , otblue multisensor fire detector iq8quad with isolator as per atc , optical smoke detector iq8quad with isolator as per atc , controller for lhdc as per atc , esserbus transponder rzt 24 v as per atc , flame detectors as per atc , usb cable ab and serial connecting cable as per atc
Tender For spares for fas detector removal tool as per atc, loop card micro module as per atc, serial esser net interface modules as per atc, network card essernet series 2 nw card 64 k as per atc, main fire alarm control panels cpu card for facp as per atc, iq8 repeaterpanel as per atc , heat detector as per atc, otg multisensor fire detector co iq8quad with isolator as per atc, o2t multisensor fire detector iq8quad with isolator as per atc, otblue multisensor fire detector iq8quad with isolator as per atc, optical smoke detector iq8quad with isolator as per atc, controller for lhdc as per atc, esserbus transponder rzt 24 v as per atc, flame detectors as per atc, usb cable ab and serial connecting cable as per atc