Get complete information related to latest Resectoscope Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resectoscope Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resectoscope Tenders.
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For corrigendum : supply of hysteroscopic instruments - supply of hysteroscopic instruments, diagnostic hysteroscope-- feature specification- outer diameter 2.7 mm - working length 250 mm 300 mm- angle of view: 30 - field of view wide-angle ( 80 )- image transmission rod lens system (preferred), or fiberoptic- sheath size 3.5 mm (outer sheath)- distension media normal saline or co (based on system compatibility)- light source connection standard fiber optic light post (compatible with xenon or led sources)- port type luer lock inflow port (optional outflow depending on model)- sterilization autoclavable or low-temperature plasma sterilization- material surgical-grade stainless steel and medical-grade polymers, operative hysteroscope (4 mm)- telescope diameter 4.0 mm- working length 270 300 mm- outer sheath diameter 5.5 mm (depending on continuous flow or single-flow sheath)- working channels 1 or 2 channels, standard 5 fr (1.7 mm) instruments- angle of view 30 (standard)- field of view wide-angle, distortion-free- image system rod lens optical system, hd-compatible- sheath type continuous flow (inflow and outflow channels)- material surgical-grade stainless steel- light transmission fiber optic light post, universal connector- distension media compatibility normal saline (for bipolar energy) or non-electrolyte fluid (for monopolar)- electrosurgical compatibility bipolar or monopolar electrodes (rollerball, loop, hook, etc.)- electrode type supported 5 fr electrodes resectoscope type- instrument compatibility operative scissors, graspers, biopsy forceps (5 fr)- sterilization autoclavable (134 c) or low-temperature plasma sterilization, hysteroscopic resectoscopesheath & telescopeouter diameter: 4.0 mm working channel: 1.5 2.0 mm (for scissors, biopsy forceps, graspers, bipolar electrodes)angle of view: 30 length: ~25 30 cmfibre optic light transmission with high-resolution rod lens systemresectoscope system (if using with loop / rollerball)available as mini-resectoscope (4.0 mm)compatible with bipolar energy sourceworking element: spring-loaded resectoscope with 4 mm telescopeelectrodes: loop, rollerball, knife, needle (bipolar compatible)fluid managementcompatible with saline (0.9%) as distension medium (for bipolar)continuous flow sheath for clear visioninflow/outflow channels for pressure-controlled irrigationother featuresautoclavable stainless steelergonomic design for operative stabilitycompatible with standard hd camera and light source systems, hysteroscopic scissors size: 5 fr (~1.7 mm), 30 36 cmpasses through working channel of 4 mm hysteroscope.types: straight / curved / angledmaterial: stainless steel, autoclavable, hysteroscopic biopsy forcepssize: 5 fr (~1.7 mm), 30 36 cm long.fits into working channel of 4 mm operative hysteroscope.types: biopsy (punch), grasping, scissors.jaws: serrated, single/double action, rotatable.reusable (autoclavable)., hysteroscopic morcellatorsystem componentshandpiece with cutting blade (rotating/reciprocating)inner cutting tube (sharp-edged) inside outer sheathcontinuous suction attached simultaneous cutting + tissue removalcompatible hysteroscope sheathdimensionssheath outer diameter: 6 7 mm (mini systems available with 5 mm)working channel: 3 3.5 mm (for morcellator blade)blade sizes: 2.5 3 mm (straight or side-facing cutting window)length: 26 30 cmoptics0 or 12 telescope, 2.9 4 mm rod lenshigh-definition fibre-optic illuminationenergy / working principlemechanical cutting continuous suction for clear vision and specimen collectionworks with normal saline as distension medium, hysteromat fluid management systemspecificationsmedium used: co (rarely now) or, preferably, fluids (normal saline, glycine, mannitol, sorbitol).pressure range: adjustable, usually 30 150 mmhg.flow rate: 50 500 ml/min (depending on model).display: digital display for set pressure, actual pressure, inflow, outflow, and fluid deficit.safety: audible alarms for excessive pressure or fluid deficit (to prevent ove