Web Analytics Made Easy - StatCounter

Resistance Temperature Detector Tenders

Get complete information related to latest Resistance Temperature Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resistance Temperature Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resistance Temperature Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :45658109 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For " mill worm shaft thrust rtd code ba9718594039 l- 198mm make: detriv resistance temperature detector: s , " mill worm shaft radial rtd code ba9718594047 l- 188mm make: detriv resistance temperature detector: s , " mill thrust bearing rtd code ba9718594053 l- 468mm make: detriv resistance temperature detector: shea , " mill return oil rtd code ba9718594016 l= 50mm make: detriv resistance temperature detector: sheath m

CTN :45632577 Due date: 11 Jul, 202611 Jul, 2026 NA
Tender For resistance temperature detector

corporations/Associations/Others

CTN :45608041 Due date: 18 Jul, 202618 Jul, 2026 21.06 Lacs
Tender For procurement of cems spare parts - sample pump, sample pump valve plate, sample pump diaphragm, digital temperature indicator (dti), z d l (convertor), . ir source with chopper motor assembly, 4-20 mili amp. card, silicon tube- 6 mm od x 4 mm id, silicon tube- 8 mm od x 6 mm id, silicon tube- 12mm od x 10mm id, resistance temperature detector (rtd), drain pump/peristatic pump, drain pump roller, . sox, nox cylinder 47 ltr, co, co2 cylinder 47 ltr., n2 cylinder, 47 ltr, gas regulator with pressure gauge, heat tracing line

CTN :45535219 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys

CTN :45516001 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto

State Government

CTN :44943510 Due date: 19 Jun, 202619 Jun, 2026 22.54 Crore
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - bottle dispenser, deep freezer -20°, 400 l, deep freezer -40°c, capacity 400 l, abbe, refractometer, automated solid, phase extraction, system, electro magnetic, sieve shaker, solvent filtration, unit, automatic, glassware, washers and, dryers, rotary evaporator, with chiller, homogenizer, ultra sonic bath, digital butyro, refractometer, analytical balance, (0.0001 gram, (accuracy), hot air oven, polarimeter, ph meter, muffle furnace, vacuum oven, deep freezer -80°c, micro balance, refrigerator 700 l, (double door &, frost free), water purification, system, inductively coupled, plasma – mass, spectrometer (icpms), microwave digestor, gas chromatography, with tandem mass, spectrometry (gcmsms), lc-ms/ms, ics aquion - specs, ultra performance, liquid, chromatography, (uplc) with photo, diode array, (pda),fluorescence, (fld) and, refractive index, detector(rid)

Central Government/Public Sector

CTN :44286906 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For bid to ras supply of resistance temperature detector pt-100 (rtd) , k type thermocouple ( immersion length 650 mm) , k type thermocouple ( immersion length 400 mm)

CTN :45358061 Due date: 18 Jun, 202618 Jun, 2026 NA
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co

CTN :45346428 Due date: 15 Jun, 202615 Jun, 2026 NA
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign

CTN :45346446 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to
 Loading, Please wait...

Connect us via What's Up