Get complete information related to latest Resistive Load Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Resistive Load Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Resistive Load Bank Tenders.
Tender For integrated wtcc for lhb gs & scn amrit bharat coaches , as per drawing: lg10486 alt. 'e', packing instruction: 1. the supplier shall pack the integrated wtcc in a suitably designed returnable fixture in such a way that integrated wtcc shall not get scratched, damaged, twisted during transportation, storage and lifting and to avoid scratches on outer surface. it should be wrapped with enviroment friendly material and it should have standard clamping /fastening mechanism so that it can be opened easily. it should have firm's identification mark. 2. first returanable fixture along with integrated wtcc be retained by rcf & this fixture shall be exchanged in the second lot supply and so on. at the end of the contact, the firm shall collect the remaining returnable packing fixture from rcf. 3. the packing fixture/frame to be fabricated having sufficientstrenght to bear approximate 1 tonne load in static & moving condition of two coach set of integrated wtcc. 4. the fixture /frame/pallet should be designed so that the packed wtcc remain preferably in horizontal position to minimize surface area. 5. it should also be suitable for storage of integrated wtcc under open sky. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of 3 pol mcb , 3 core armed aluminium cable , slim dc power supply variable up to 30v 5a , l-2 switch , crimping tool kit set of 6 items , laser distance meter , clamp meter , multifunctional network tester , non-contact voltage tester , professional heat gun , 6a 16a 240v ac 3 pin nickel plated brass adaptor , insulation tape roll , lane tester , clumping tools , electric tester , ofc joint coupoler box , odc dc fan , patch card for odc lc to lc , metal juncation box for fix camera , body cover of radio set tk 2317 , armoured power cable coper 2 core , lt wire 8 10 mm for series connector for bty copper based , fiber clener solution liquid , joint closure 24 core , extension board 10 amp output 250 v with 2 mtr extension cord surge protector , whip antenna of radioset tk 2317 , bty lead of kw tk7360 , power cable 2 core copper 4 mm , co-xial cable 52 ohm rg 58 , 12 v 2 amp. dc adapter , mcb box enclosure as per site requirement , 3 core 6 sqmm copper flexible cable , installation and commissioning at mandav and pithampur ) /bid number : gem/2026/b/7594394 * /dated: 27-05-2026 & & / bid document 1 / 28
Tender For tender for supply and installation of ophthalmic equipment under npcb&vi programme - streak-retinoscope, non contact tonometer, digital led vision chart, trial set with the trail frame, auto-refractometer, anterior segment and posterior segment fundus camera with compatible viewing system
Tender For supply of class b & c surge protection device (spd) -type i & ii with visual indication and potential free contact to remote monitoring as per specification no. rdso/spn/165/2012 ver 3.0 or latest andiec standard 61643 for single line 230v ac application with handling lightning surges of 10/350 microseconds and switching surges of 8/20 microseconds .one set consists of 3 nos. of spd (2 no. of b class (l-n, n-e) and one no. of c class (l-n) all enclosed in a box with kema or vde certified as per latest iec 61643-11-2011 standard. class b &c surge protection device required with three modules only. installation of class b & c surge protection device should be as per the tan no:- sts/e/tan/3006, version- 3.0 ; dated:- 08.01.2025 (tan specs attached as annexure.) [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of "set of push button switches with 22.5mm cut out dia, as per specification no. mr/poh/e/t&c/001(rev-1), drawing no. mr/poh/7/5/0299-2 alt. a for ac rakes of kolkata metro. nb: (1) one set consists of 30nos. green colour push buttons, 34nos. red colour push buttons and 18nos. yellow colour push buttons. (2) 04nos. push button switches should be provided with 01no. contact element with contact configuration (1no. +1nc). (3) the remaining push button switches should be provided with 01no. contact element with contact configuration 2no." as per drg.no. drawing no .mr/poh/7/5/0299-2 alt. a. specn: as per specification no .mr/poh/e/t&c/001(rev-01), [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of electrical spare parts required for streetlights and town panchayat buildings. - 4 feet flourescent tube light, 40w copper choke, 40w tube light starter, 36w / 40w tubelight electronic choke, tube light side lock holder, insluation gum tape roll - isi, 1/18 vir copper wire [1/44] [90mtr], 3/20 cts copper wire [3/36] [90mtr], 7/20 cts copper wire [7/34] [90mtr], 7/16 cts copper wire [7/67] [90mtr], 19/16 cts copper wire [19/51] [90mtr], 1.5 sq.mm 3 core copper cable, 2.5 sq.mm 3 core copper cable, 4 sq.mm 3 core copper cable, 6 sq.mm 3 core copper cable, 10 sq.mm 3 core copper cable, 16 sq.mm 3 core copper cable, 36w 4pin lamp holder, 36w lamp clip, 24w t5 holder, led fitting top protection glass - street light, led fitting top protection glass - flood light, 20 / 25 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 32 / 40 mm 1 no gi bend pipe, with 2nos of pole clamps with bolts and nuts, 6amps to 32 amps sp mcb, 40amps 2pole isolator, 63amps 4pole isolator, 32a d.p switch, mcb box, fuse unit 16 amps 240v, fuse unit 32 amps 415v, fuse unit 63 amps 415v, fuse unit 100 amps 415v (heavy duty), fuse unit 200 amps 415v (heavy duty), fuse unit 300 amps 415v (heavy duty), fuse unit 400 amps 415v (heavy duty), fuse unit 500 amps 415v (heavy duty), main switches spn 32 amps, main switches tpn 32 amps, main switches tpn 63 amps, main switches tpn 100 amps, main switches tpn 315 amps, 63a 4pmc changeover switch, 100a 4pmc changeover switch, automatic on/off street light timer switch with 24hrs 7 days programable digital timer clock, 40 amps 4 pole contactor with coil, mcb switch and connector fully wired with all accessories, street light meter/main box with wooden board, main switch, fuse carrier fully wired with all accessories, electronic 7 days 24 hrs programable ditial timer clock, 63 amps 4 pole contact with coil, 220v - 250v contactor coil, power capacitor, 9w led bulb, 15w led bulb, 30w led lamp, 24w t5 power saver lamp, 2x24w t5 power saver choke, 36w 4 pin non retrofit type cfl power saver lamp, 36w 4 pin non retrofit type cfl power saver choke, 20w high bright led 4 feet light, 20w led power saver street light fitting, 25w led power saver street light fitting, 30w led power saver street light fitting, 36w led power saver street light fitting, 50w led power saver street light fitting, 60w led power saver street light fitting, 72w led power saver street light fitting, 90w led power saver street light fitting, 120w led power saver street light fitting, 100w led power saver flood light fittings, 150w led power saver flood light fittings, 200w led power saver flood light fittings, 40w all-in-one solar led street light fittings, 60w all-in-one solar led street light fittings, 80w all-in-one solar led street light fittings, 18w to 25w led chip board, 30w to 36w led chip board, 45w to 60w led chip board, 72w to 90w led chip board, 120w to 200w led chip board, 18w to 25w led heavy duty electronic driver, 30w to 36w led heavy duty electronic driver, 45w to 60w led heavy duty electronic driver, 72w to 90w led heavy duty electronic driver, 120w to 200w led heavy duty electronic driver, 10 kv surge protector, 48` ceiling fan with all accessories, d.o.l motor starter up-to 10 hp, 10metre hot dip galvanised octogonal pole with round ring arm and 4nos of strong 5feet anchor bolts, templates, and nuts etc.. complete set, 1 hp to 3hp single phase control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 5 hp to 7.5hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., 10 hp to 25hp three phase fasd - auto-start / dry run protection control panel with contactor, relay, auto-start preventor, volt meter, amps meter, etc.. complete in a suitable powder coated enclosure., g.i swaged tubler 6 me
Tender For supply of set of 3 pole power contactor as per different rating comprising of 04 items (i) 415v, 110a, 60kw, coil voltage 15mt.3.11 with auxiliary contact 1no+1nc for main hoist panel and protective panel, qty: 02 nos./set, (ii) 415v, 73a, 37kw, coil voltage 110v ac, type ce15kn3 with aux. contact 1no+1nc for main & aux. hoist, lt and protective panels. qty: 03 nos. /set, (iii) 415v, 40a, 22kw, coil voltage 110v ac, type ce15gn3 with aux. contact 1no+1nc for lt and ct panels. qty: 02 nos. /set, (iv) 415v, 25a, 11kw, coil voltage 110v ac, type (ce15en3.b10-n & ce15en3.b01-n) with aux. contact 1no+1nc for ct panel. qty: 02 nos. /set, [ warranty period: 30 months after the date of delivery ] ]