Tender For supply of replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For m and r work under edd- rania -loading 8.5 m long pcc pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a loading 11 m stp pole from electricity storage centre jainpur on own vehicle and taking it to work site and unloading it safely through unpaved road. a transport of electric line material like conductor, clamp, nut-bolt wire, lt cable, stonepad, station set, xlpe, abc etc. to the specified place by own vehicle for an estimated distance of 75 km through unpaved road. a digging pit at the place of broken/damaged poles and installing pcc poles by tying all accessories like cross arm, disc, pin insulator etc. and fitting earthing rod. a tying all accessories as per requirement in the long span in the middle of the already constructed line. the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link. a the work of re-energizing by installing additional pcc/stp poles as per the prescribed standard/specification of response link while tying all the accessories as per requirement in the middle long span of the already constructed line. a installation of new section double pole in place of broken/damaged double pole. a grouting work of pcc/stp poles as per respo standard. supplying cement, ballast, gravel in the ratio of 1:2:4. repairing section double pole. tightening damaged stays by renosing. tightening the white wires of 33 kv line, each wire and tightening the white wires of lt and 11 kv line, each wire. straightening the skewed poles of 33 kv line/11 kv line/lt line as per respo standard and tying all accessories and erecting them correctly. giving clearance by trimming the trees of 33/11 kv and lt line. spreading the acsr vessel conductor in 33/11 kv line and tying stringing and sagging insulators in all the three phases and jumpering and earthing each wire. replacing damaged cross arm.
Tender For spl repairs/ replacement of lt panel alongwith associated wor main building (p-83 (ca) and opw building at afcao, provision of water tank with booster pump for left over map building at camero complex and provn of anti sucide fan rod for certain smqs at came
Tender For corrigendum : supply of various type material - supply of following materials as per respo norms & drawings :-, lt bushing rod made of brass suitable for 63/100 kva t/f having 4 brass nut, 1 brass washer and 1 rubber gulli, lt bushing rod made of brass suitable for 250 kva t/f having 4 brass nut, 1 brass washer and 1 rubber gulli, lt bushing rod made of brass suitable for 400 kva t/f having 4 brass nut, 1 brass washer and 1 rubber gulli, lt bushing rod made of brass suitable for 630 kva t/f having 4 brass nut, 1 brass washer and 1 rubber gulli, aluminum crimping type lugs for lt side suitable for 1000 sqm., aluminum crimping type lugs for lt side suitable for 630 sqm., aluminum crimping type lugs for lt side suitable for 400 sqm., aluminum crimping type lugs for lt side suitable for 240 sqm., aluminum crimping type lugs for lt side suitable for 150 sqm., aluminum crimping type lugs for lt side suitable for 120 sqm., aluminum crimping type lugs for lt side suitable for 70 sqm., tinned copper fuse wire of size 22 swg (for 1000 kva), tinned copper fuse wire of size 24 swg (for 630 kva), tinned copper fuse wire of size 27 swg (for 400 kva), tinned copper fuse wire of size 30 swg (for 250 kva), tinned copper fuse wire of size 30 swg (for 160 kva), tinned copper fuse wire of size 37 swg (for 100 kva), tinned copper fuse wire of size 39 swg (for 63 kva), tinned copper fuse wire of size 40 swg (for 25 kva), l clamps made of copper flate of size 50 6mm and hole at both end suitable for 250 kva t/f., l clamps made of copper flate of size 50 6mm and hole at both end suitable for 400 kva t/f., l clamps made of copper flate of size 50 6mm and hole at both end suitable for 630 kva t/f., aluminum bolted type clamp for lt side suitable for 630 sqm, aluminum bolted type clamp for lt side suitable for 400 sqm, aluminum bolted type clamp for lt side suitable for 240 sqm, lt packing kit made of best quality rubberised cork sheet, pvc tape, ht tape, m seal, silica gel of size 2 to 4 mm
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For corrigendum : supply of call base repair of ems at telephone bhavan - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For repairing and servicing of dg set - coolent , filter , oil , battery , repari job , earthing , tightening of nut bolts , tightening of bushing , cleaning of dust , replacement of jumpers , lt side bushing rod , ht side bushing rod , lt side porcelain bushing , ht side porcelain bushing , 40p cover tankrubberized cork gasket , defactive drain valve , l type connectors , transformer fresh oil , buy back price of the oil , 11kv isolator , 11kv horn gap fuse set , oil filteration , lt side fuse , flexible pvc wire , spray painting