Get complete information related to latest Ring Main Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ring Main Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ring Main Machine Tenders.
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For tender for supply of spare parts - power contactor 16a at 415v ac coil 24v dc model3tf32 00 0bb4 power contactor biasing damper 24vdc siemens , siemens 3rh1921 1ba01 auxiliary contact block make siemens model 3rh19211ba01 type front top mounted auxiliary contact block contacts 1 no normally open electrical ratings pilot dutyac a600 600 v ac 10 a continuous dc q600 300 v , siemens 3rh19211ca01 auxiliary contact block make siemens model 3rh19211ca01type front top mounted auxiliary contact block contacts 1 nc electrical ratings pilot duty ac , siemens 3tf30 100a power contactor aa11 make siemens model 3tf30 100a type power contactor poles 3 main poles rated operational current ac3 9 a at 415 v ac auxiliary contacts 1 no integrated coil voltage 110 v ac 50 60 hz rated insulation voltage ui 690 v utilization category ac3 ac4 mounting din rail or screw mounting standards iec 6094741 is iec60947 4 kw at 400 v ac power contactor silo , 3ua52 002a thermal overload relay make siemens model 3ua52 002a type thermal overload relay current range 10 16 a trip class 10a reset mode manual automatic auxiliary contact 1 no 1 nc rated insulation voltage ui 690 v mounting direct mount to siemens 3tf30 31 contactors or separate base protection of motors against overload phase failure and unbalanced load standards iec 6094741 thermal overload relay swas , siemens 3th30 220a auxiliary contactor relay make siemens model 3th30 220a type auxiliary contactor relay contacts 4 2no 2nc rated operational current ie 10 a ac15 4 a at 230 v 2 a at 400 v rated insulation voltage ui 690 v coil voltage 110 v ac 50 60 hz standard compliance iec 6094751 mounting din rail or panel mounting , semiconductor fuse rating 10a size 000 make siemens , semiconductor fuse rating 2a size 000 make siemens , semiconductor fuse rating 4a size 000 make siemens , semiconductor fuse rating 6a size 000 make siemens , auxiliary contactor coil dc with 2no 2nc contacts model 3th30 22 0bb4 siemens , motor protection with overload relay function mpcb biasing damper 24vdc motor protection circuit breaker size s00 with overload relay model 3rv2111 1da10 overload release setting 22 32 a short circuit release 42 a size s00 function motor protection w overload relay connection type screw terminal screw terminal suitable motor 400v 11 kw biasing damper 24vdc , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating mcb swas make siemens , type 3 pole power contactor make siemens series sirius model 3rt2015 2ab01 coil voltage 24v ac 5060 hz utilization category ac1 18 a ac3 7 a rated voltage up to 690 v motor rating ac3 1point 5 kw 230v 3 kw 400v 4 kw 690v auxiliary contact 1 no 1314 built in terminals main 1l1 3l2 5l3 2t1 4t2 6t3 coil a1 a2 mounting din rail panel standard iecen 60947 41 power contactor silo , motor starter protector mpcb silo motor protection circuit breaker size s00 model 3rv2011 1aa10 standard mpcb size s00 trip function thermal magnetic main application simple motor switching protection connection type screw terminal screw terminal number of poles 3 adjustment range current 1point 1 to 1point 6 a instantaneous release magnetic 21 a trip class 10 operational voltage 20 to 690 v ac insulation voltage 690 v ac surge voltage resistance 6 kv mains frequency 5060 hz mpcb silo , type 3 pole contactor model 3ts30 100a make siemens specifications type 3 pole contactor coil voltage 230v ac power rating at 415v 4 kw approx auxiliary contact 1 no rating ac1 25 a ac3 9 a utilization category standard ac3 duty motor application up to 4 kw 415v 3 phase3 power contactor higher rating swas make siemens , thermal overload relay model 3us50 001k8k current range 8 12point 5 a tolr swas co ordination type 2 25a type 3na make siemens , add on auxialiry c
Tender For 1.5 ton ac, inverter type split air conditioners suitable for operation on a/c supply single phase 50 hz 230v with hermetically sealed inverter compressor with air cooled condenser latest r410a/r-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit with one indoor & one outdoor unit. the condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube and suitable capacity 3 core sheathed/ pvc copper cable and a battery operated wireless remote unit and outdoor stand. (detailed specification is as per enclosed spec copy) [ warranty period: 12 months after the date of delivery ]