Get complete information related to latest Ring Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ring Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ring Plate Tenders.
Tender For corrigendum : various routine/preventive and breakdown maintenance work on as and when require basis at chp-gtps - replacement of hammer rings for stage ii crusher , replacement of hammer rings for stage i crusher , replacement of screen plate / breaker plate/kick off plate of stage i and ii crushers , replacement of rotor of stage i crusher with disassembling of removed rotor and assembling of new/repaired rotor , replacement of drive end side bearing / pedestal of crusher rotor or complete gear coupling set of crusher or repositioning of dislocated rotor of crusher , replacement of non drive end side bearing/pedestal of crusher rotor or complete alignment of crusher motor with crusher rotor , replacement of broken hammer rings of stage i and ii crushers (stage i crusher up to 12 nos.of hammer rings and stage ii crusher up to 06 nos. of hammer rings at a time) , replacement of rail of rail table of wagon tipplers 1/2/3/4 (in one side full length) , replacement of clamping rubber pads of clamp for wagon of wagon tipplers , replacement of whole resting pads for wagon of side beam of wagon tipplers , replacement of spill plate roller of wagon tipplers , repairing/preparation/ fitting and replacement of hooks/rods/turn buckle, chain, sling rope ,spring assembly etc. of vibrating trays and crusher house trays , spillage control at various locations , miscellaneous cutting/welding work require at various locations , replacement of gearbox in conveyor no. 2a/b,11a/b,12a/b,13,14/15,16a/b,17a/b ,18a/b,drc/apron/rg/,wagon tipplers,stacker-reclaimer , replacement of gearbox in conveyor no.,5a/b,8a/b,10a/b,shuttle conveyor 1/2,belt feeder 1/2 ,roller screen, mrc 3/4/5,wobbler feeder ,dribble conveyor 1/2 , replacement of slow speed coupling set (two halves) of drive pulley , replacement of coupling bolts and rubber bushes of slow/high speed coupling(input/output coupling ) in conveyor no.2a/b,11a/b,12a/b,13,14/15,16a/b,17 a/b,18a/b,drc/apron/rg/,wagon tipplers,stacker-reclaimer , replacement of coupling bolts and rubber bushes of slow/high speed coupling(input/output coupling ) in conveyor no.,5a/b,8a/b,10a/b,shuttle conveyor 1/2,belt feeder 1/2 ,roller screen, mrc 3/4/5,wobbler feeder ,dribble conveyor 1/2 , replacement/removing/refitting of various size and type of fluid coupling , replacement or removing & refitting of any internal/bearing/input/ output oil seal of various size and type of gear box , overhauling of dismantles old/used gearbox in all respect with fitment of input and output coupling. , replacement of drive pulley , replacement of drive end side bearing of drive pulley or repositioning of dislocated drive pulley , replacement of non drive end side bearing/any side pedestal of conveyor drive/non drive pulley , alignment of motor/ gearbox/drive pulley including decouple/couple of coupling , nut bolt and drive system checking with replacement of broken nut bolt in all 04 wagon tipplers no.1/2/3/4 as per scope , lifting and releasing of gravity take up of any conveyor belt for locking and de locking of belts for other than belt replacement work , loosening and tightening of horizontal type screw take assembly of any conveyor belts for other than belt replacement work , work of dismantling and re erection of new/repaired apron pan from existing apron feeder of wagon tippler , repairing of upper/lower structure/cone plates of damaged/bend apron pan , replacement of carrying roller of apron feeder , replacement of worn out/ damaged ti roller and garland rollers. , replacement of worn out/ damaged impact rollers , replacement of worn out/ damaged return rollers , replacement of various worn out/ damaged ti roller stands , replacement of various worn out/ damaged impact roller stands , replacements of various worn out/ damaged return roller stands , replacement of various worn out skirt rubbers [10 m each] and skirt rubber with angle , preparation and replacement of guide rollers with bracket in place of worn out/ damaged gu
Tender For e- tender for supply of spine, fms other implants high end - frame plate 3d (micro plates 0.2mm - 0.8mm), dermal matrix wound dressings size 10x25cm, dermal matrix wound dressings size 10x12.5 cm, dermal matrix wound dressings size 5x5 cm, jess fixators for hand fracture, suture anchors (for tendon achilles repair), rack for 8 instruments with clamp box, instrument case 130 x 230 x 25mm, micro scissors straight scissor blade 10mm, forceps with plateau tip 0.3mm smooth, micro forceps with plateau tip 0.6mm angulated, micro scissors curved - scissor blade 10mm, double clamps 24mm, 1.5 - 2.3mm vessel, double clamps 16mm, 1.0 - 2mm vessel, double clamps -11mm, 06-1.4mm vessel, single clamps 24mm, 0.6 - 1.4mm vessel, single clamps 16mm, 0.6 - 1.4mm vessel, microvascular single clamps 11mm, 0.6 - 1.4mm vessel, calcaneal fracture fixation plate and screws, lisfranc plate and screws, first 1st mtp fusion plate and screws, lapidus fusion plate and screws, mini tight rope for mallux valgus, ankle fusion plates, fibre wires, achilles tendon repair by speed bridge, foot plates, memory staples, tenodesis screws, syndesmosis repair with tight rope, suture anchors for brostrum repair, internal brace for brostrum repair, deltoid ligament repair using suture anchors, deltoid ligament repair with internal brace, autocart - all autologous cartilage regeneration, suture anchors for achilles tendon 5.5 mm double loaded with needles, extra osseous talotarsal stabilization (eotts) implant (sinus tarsi screw), screws for corresponding plate thickness of length 4mm, 6mm, 8mm, 10mm (large 2mm to 2.8mm), a)10 hole continuous plate (large 2mm to 2.8mm), a)6 hole with gap (large 2mm to 2.8mm), a)4 hole with gap (large 2mm to 2.8mm), a)3 hole with gap (large 2mm to 2.8mm), a)2 hole with gap (large 2mm to 2.8mm), h plate (large 2mm to 2.8mm), l plate right and left (large 2mm to 2.8mm), titanium strut plate 18 hole (large 2mm to 2.8mm), double y plate (large 2mm to 2.8mm), y plate (large 2mm to 2.8mm), a)20 holes adaptation plate (large 2mm to 2.8mm), screws for corresponding plate thickness of length 4mm, 6mm, 8mm, 10mm (medium plates 1mm-2mm), a)10 hole continuous plate (medium 1mm to 2mm), a)6 hole with gap (medium 1mm to 2mm), a)4 hole with gap (medium 1mm to 2mm), a)3 hole with gap (medium 1mm to 2mm), a)2 hole with gap (medium 1mm to 2mm), h plate (medium 1mm to 2mm), l plate right and left side (medium 1mm to 2mm), titanium strut plate 18 holes (medium 1mm to 2mm), x plate (medium 1mm to 2mm), double y plate (medium 1mm to 2mm), y plate (medium 1mm to 2mm), a)20 holes adaptation plate (medium 1mm to 2mm), orbital mesh (0.2- 0.4mm), screws for corresponding plate thickness of length 4mm, 6mm, 8mm, 10mm (micro plates 0.2mm - 0.8mm), a)10 hole continuous plate (micro plates 0.2mm - 0.8mm), a)6 hole with gap (micro plates 0.2mm - 0.8mm), a)4 hole with gap (micro plates 0.2mm - 0.8mm), a)3 hole with gap (micro plates 0.2mm - 0.8mm), a)2 hole with gap (micro plates 0.2mm - 0.8mm), titanium strut plate 18 holes (micro plates 0.2mm - 0.8mm), x plate (micro plates 0.2mm - 0.8mm), double y plate (micro plates 0.2mm - 0.8mm), y plate (micro plates 0.2mm - 0.8mm), a)20 holes adaptation plate (micro plates 0.2mm - 0.8mm), orbital rim (micro plates 0.2mm - 0.8mm), deformity reduction set, cobalt chromium rods 5.5 mm x 400 mm, mis battery or manual operated disc aspirator 1-2.5 mm, with 0.5 mm increment 13 - 19 gauge with 2mm increment straight or curved, anterior peek cervical standalone cage, intergrated peek cage with titanium screw locking mechanism 6mm-12mm length, self locking screw mechanism, 35 degree screw angulation cephedal to caudal, self drilling screws 3.5mm, 4mm, mis polyaxial set scerw accomadating 5.5mm rods, mis contoured or straight rods dia 5.5mm with sharp edge for edge for easy insertion, mis polyaxial screw with attachment option of plastic retractor for direct imaginga and visualization of rod, modified design for set screw insertion dia 5 t
Tender For e- tender for supply of orthopaedic trauma and arthroplasty implants high end - hemihydrate calcium sulphate kit 10- cc, hemihydrate calcium sulphate kit -5 cc, distal femur nails for standard and periprosthetic fractures with larger distal bends and with locking attachment washer or condular nuts and washers, us fda approved, reamer bone harvesting kit with reamer head and reaming rod , us fda approved , variable angle locking calcaneal plate 2.7mm with/without tab small/medium/large -, 2.7mm va locking screw -, 2.7 mm metaphyseal screw 2.7mm cortex screw variable angle locking screw should have option to lock at plus -15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., low profile distal tibial medial plate 3.5mm,6-14 holes,titanium, locking head screw 3.5 mm, l 10-60 mm, titanium, cortical screw 3.5 mm self tapping, l 10-60 mm, titanium, cancellous screws 4mm full/half threaded, l-20-80mm,titanium variable angle locking screw should have option to lock at plus -15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., lcp anterolateral distal tibia plate 3.5mm, right or left,(5-21)holes, titanium, locking head screw 3.5 mm, l 10-60 mm, titanium, cortical screw 3.5 mm self tapping, l 10-60 mm, titanium, cancellous screws 4mm full/half threaded, l-20-80mm,titanium, radial head replacement system is a solution for replacing the radial head for radial head fractures to restore elbow stability and forearm rotation to maintain the legth of radius. implants should be available in 19 mm,22 mm,25 mm variant and available in stem varing 5.5 mm to 8.5 mm and stem length 21 mm to 24. the implants should be uncemented with all instruments in sterile form for one time use., polymethylmethacrylate (pmma) injectable bone cement system for augmentation of proximal femoral nailing system (tfna) through cannulated implants and instruments for patients with poor bone quality (such as osteoporosis). its applicator allows surgeons to inject cement into the femoral head through cannulated implants, reducing the risk of cut-out, locking attachment plate 3.5 mm is a fixed-angle construct in periprosthetic fractures and fractures in the presence of intramedullary implants, particularly in osteopenic bone where screw purchase is compromised the plate is attached to existing locking compression plates (lcp using a connecting screw, to augment stabilization of fractures.the arms on each side of the plate offer the possibility of bypassing the prosthesis stem with 3.5 mm locking screws (or 3.5 mm cortex screws)., locking anterior patella variable angle plate for simple and complex patella fractures should have range of plates - core, to address different fracture pattern with 2.7 mm va locking screws and 2.7 cortex screws. variable angle locking screw should have option to lock at 15 degree off axis in any direction compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce/bis standard compliant., variable angle locking hand system consists of plates that are anatomic, procedure-specific for the fracture fixation of metacarples and phalanges, 1.3 mm profile plate configuration includes either straight plate/ t-plate/phalangeal base plate/y- plate/strut plate/web plate/phalangeal head plate, the construct consists of plate 1.3 mm, va locking head screw 1.3mm, cortical screws 1.3 mm., variable angle lcp clavicle plate which can be used for lateral extension, medial, shaft, anterior and for ac joint fracture. the construct consist of plate, locking head screw 2.7 mm and cortical screws 2.7 mm, (compele range of size shape and side specific implant with instumentation at the time of surgery.implant should be us fda/eu-ce stan
Tender For supply of wago connector (terminal block) 4 conductor 2.5 sq. mm. with end plate as per wago cat. no. 280- 833 & amp; 280-314 or fully equivalent. [ warranty period: 30 months after the date of delivery ]