Get complete information related to latest Ring Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ring Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ring Terminal Tenders.
Tender For echp-i- operation of electromagnet in conveyor-43 head end ilms and removal of metal pieces picked by the magnet under works contract from the date of entrusting the work and upto 31.03.2026.
Tender For procurement of crimping sockets - 6 sq mm aluminium crimping socket , 10 sq mm aluminium crimping socket , 16 sq mm aluminium crimping socket , 25 sq mm aluminium crimping socket , 35 sq mm aluminium crimping socket , 50 sq mm aluminium crimping socket , 70 sq mm aluminium crimping socket , 95 sq mm aluminium crimping socket , 120 sq mm aluminium crimping socket , 150 sq mm aluminium crimping socket , 185 sq mm aluminium crimping socket , 240 sq mm aluminium crimping socket , 10 sq mm aluminium in line connector , 16 sq mm aluminium in line connector , 25 sq mm aluminium in line connector , 35 sq mm aluminium in line connector , 50 sq mm aluminium in line connector , 70 sq mm aluminium in line connector , 95 sq mm aluminium in line connector , 120 sq mm aluminium in line connector , 150 sq mm aluminium in line connector , 185 sq mm aluminium in line connector , 240 sq mm aluminium in line connector , 16 sq mm copper crimping socket heavy duty , 25 sq mm copper crimping socket heavy duty , 35 sq mm copper crimping socket heavy duty , 50 sq mm copper crimping socket heavy duty , 70 sq mm copper crimping socket heavy duty , 95 sq mm copper crimping socket heavy duty , 120 sq mm copper crimping socket heavy duty , 150 sq mm copper crimping socket heavy duty , 185 sq mm coppercrimping socket heavy duty , 240 sq mm coppercrimping socket heavy duty , 2.5 sqmm copper ringterminal , 6.0 sqmm copper ringterminal , 10.0 sqmm copper ringterminal , 16.0 sqmm copper ringterminal , 25.0 sqmm copper ringterminal , 35 sqmm copper ringterminal , 50 sqmm copper ringterminal , 70 sqmm copper ringterminal , 120 sqmm copper ringterminal , 2.5sqmm copper fork terminal , 2.5sqmm copper pin type socket , 4sqmm copper pin type socket , 6 sqmm copper pin type socket , 10 sqmm copper pin type socket , 16 sqmm copper pin type socket , 25 sqmm copper pin type socket , 35 sqmm copper pin type socket
Tender For supply of spares for circulation of water pump - sc050660116 nordlock washer diff wear ring for 3 point 3kv 700kw hayward tyler make bcp part no 42577 or 206 , sc050660114 screw impeller nut for 3 point 3kv 700kw hayward tyler make bcp part no 16884m16 or 45 , sc050660107 nordlock washer or tab washer lock ring for 3 point 3kv 700kw hayward tyler make bcp part no 42577or 206 , sc050660112 locking wire roll for 3 point 3kv 700kw hayward tyler make bcp part no 169xynfb or 100 , sc050660108 cap head screw sec ring or brg hsg for 3 point 3kv 700kw hayward tyler make bcp , sc050660115 nordlock washer bearing housings for 3 point 3kv 700kw hayward tyler make bcp part no 42577 or 210 , sc050660123 screw lock ring or c e brg hsg for 3 point 3kv 700kw hayward tyler make bcp part no 16884m12 or 75 , sc050660118 o ring cover end for 3 point 3kv 700kw hayward tyler make bcp part no 43023 or 1711 , sc050660124 screw main thrust seat for 3 point 3kv 700kw hayward tyler make bcp part no 16884m10 or 30 , sc050660130 spring washer main thrust seat for 3 point 3kv 700kw hayward tyler make bcp part no 17207m10 , sc050660129 split pin thrust pad for 3 point 3kv 700kw hayward tyler make bcp part no 167wbdgj62m0 , sc050660125 screw reverse thrust for 3 point 3kv 700kw hayward tyler make bcp part no 16884m10 or 65 , sc050660117 nordlock washer rev thrust for 3 point 3kv 700kw hayward tyler make bcp part no 42577 or 210 , sc050660128 split pin rev thrust pad for 3 point 3kv 700kw hayward tyler make bcp part no 167wbdgj62m0 , sc050660122 screw filter or rev thrust seat for 3 point 3kv 700kw hayward tyler make bcp part no 16201m10 or 35 , sc050660126 screw reverse thrust wear ring for 3 point 3kv 700kw hayward tyler make bcp part no 16884m6 or 30 , sc050660121 philidas nut reverse thrust for 3 point 3kv 700kw hayward tyler make bcp part no 16526m6 , sc050660127 screw stator lock ring for 3 point 3kv 700kw hayward tyler make bcp part no 41258 or 506 , sc050660110 gasket pump or motor for 3 point 3kv 700kw hayward tyler make bcp part no 42499 or 504 , sc050660109 gasket motor cover for 3 point 3kv 700kw hayward tyler make bcp part no 42499 or 504 , sc050660132 tgm termination kit for 3 point 3kv 700kw hayward tyler make bcp part no 43108 or 1 , sc050660120 o seal terminal gland stem for 3 point 3kv 700kw hayward tyler make bcp part no 36823 or 130 , sc050660119 o seal terminal gland body for 3 point 3kv 700kw hayward tyler make bcp part no 37977 or 229 , sc050660113 back up ringterminal gland for 3 point 3kv 700kw hayward tyler make bcp part no 40262 or 111 , sc050660131 tape silicon for 3 point 3kv 700kw hayward tyler make bcp part no 189wcbjb81m0 , sc050660111 heatshrink tubing for 3 point 3kv point 700kw hayward tyler make bcp part no 189wpggc81m0
Tender For supply and installation of physics instruments - c.r.o. dual trace 40 mhz: 1. type of input channels- analog and digital (mixed signal)2. number of analog channels-3. bandwidth - 300 megahertz.4. display type -colour tft.5. minimum display size- 10 inch.6. time base accuracy- 2.5 parts per million.7. sampling rate per digital channel simultaneously: 1gs/sec.8.record length per digital channel simultaneously- 8m point, function generator 0.3 to 3 mhz (scientific 10 mhz to 25 mhz frequency 1 channel function generator) : 1. frequency bandwidth (sine wave ) 10 mhz to 25 mhz.2. sample rate of arbitrary waveform generator (mega samples/sec)3. amplitude range (at 50 ohm impedance),10mv to 10 v pp., multiplexers and de-multiplexer with built in power supply :1. material- abs2. display- digital, verification of de-morgen s theorem with built in power supply : 1. type- digital2. consisting of built in power supply3. logic ics connected internally for 1st & 2nd theorem.4. 2 logic input switches with indcators.5. 1 logic output indicator.6. 3 patch chords to connect input and outputs., encoder and decoder circuit with built in power supply : 1. material- pvc2. equipment materials - glass epoxy front panel with pvc3. temperature range- -5 to 45 celsius4. output voltage(regulated) : 5vdc (internally connected), half adder, full adder, half subtractor, full subtractor with built in power supply: 1. built-in power supply dc +5 v at 500 ma.2. 3 logic input switches with green led display.3. 3 logic output red led display.4. two and gates ( 7408 ), one or gate ( 7432 )two not gates ( 7404 ) & two ex-or gates ( 7486 ) on panel., hall probe method for measurement of resistivity, complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply. (complete apparatus) : 1. hall probe (ge crystal);(b)hall probe (inas).2. hall effect set-up (digital), dhe-213. electromagnet,emu-75oremu-50v.4. constant current power supply, dps-175 or dps-50.5. digital gaussmeter, dgm-102.6. range- 0-20 ma, apparatus to study characteristics of tunnel diode : 1. instrument comprises of dc regulated power supply of 0-600mv.1. two round meter for voltage & current measurement.2. circuit diagram is printing on front panel & important connections brought out on front panel.3. with well illustrated instruction manual, photo diode characteristic apparatus : 1. material- ms2. frequency- 50hz, photo transistor characteristic apparatus : 1. instrument type- analog, solar cell characteristic apparatus (complete apparatus) : 1. analog voltmeter: 12. analog ammeter: 13. solar panel/photovoltaic cell/solar cell to study characteristics: 14. range of dc voltmeter (in volt): 305. range of dc ammeter (in milli ampere): 506. necessary patch cords for interconnection7. along with instruction manual and demonstration, apparatus to study charging and discharging of a capacitor : 1. built in power supply : +12v variable & -12v, variable dc2. mains : 230v ac, ldr characteristics apparatus. : 1. voltage- 220 v2. apparatus type- analog3. temperature range- 50-60degree, plancks constant using solar cell : 1. instrument type- digital 2. built in power supply : +12v variable & -12v3. necessary patch cords for interconnection