Web Analytics Made Easy - StatCounter

Road Grouting Work Tenders

Get complete information related to latest Road Grouting Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Road Grouting Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Road Grouting Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45474618 Due date: 22 Jun, 202622 Jun, 2026 49.00 Lacs
Tender For construction and repair of cement concrete road nagar palika area sanchore (arc)

CTN :45477065 Due date: 22 Jun, 202622 Jun, 2026 49.00 Lacs
Tender For construction and repair of cement concrete road nagar palika area sanchore annual rate contract

State Government

CTN :45417606 Due date: 11 Jun, 202611 Jun, 2026 82.79 Lacs
Tender For special repair of 30 mtr road with concrete cement along ashiyana scheme in sector-56-56a, faridabad complete in all respect and all other works contingent thereto. (including 3 year maintenance and defect liability period free of cost)

corporations/Associations/Others

CTN :45415173 Due date: 10 Jun, 202610 Jun, 2026 9.84 Lacs
Tender For construction of cement concrete track after dismantling existing damaged paver track in park near h. no. 1005, sector 21, chandigarh and repair of damaged track in park on sector 18c-sector 19d v3 road, chandigarh, under wdf.

CTN :45408937 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For repair and resurfacing of existing damaged bituminous road surface with cement concrete within the campus of 44th bn. head quarter ssb narkatiaganj sh supply of inspection vehicle for o/o the assistant engineer, bettiah central sub-division cpwd bettiah biharsubwork/packages:supply of inspection vehicle

Central Government/Public Sector

CTN :45365796 Due date: 27 Jun, 202627 Jun, 2026 11.50 Lacs
Tender For repair resurfacing of certain roads and connected items at bd bari mil stn - m&l preparing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with wire brush/brooms and finally fanning the cleaned surface with gunny bags or by mechanical blower to remove all loose dirt etc to black top surfaces, and applying evenly a priming/tack (viscosity grade paving bitumen of grade vg-10) @ 5 kg per 10 sqm to road surface bituminous asphaltic semi dense concrete consolidated thickness 30 mm with stone chippings graded aggregate with 5.5% of binder content by weight of total mix, (viscosity grade paving bitumen of grade vg-30) and 4% stone dust conforming to required specification for filler as per irc-95, 1987 (filler) by weight of mix, prepared in hot mix plant, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and rolled with 8 to 10 tone power roller completed all as specified and as directed., m&l for repair to potholes, any depth ,not exceeding 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, path etc, cutting around edges to at least 25mm in depth, making good by filling in screened and graded road metal, watering and well ramming, applying tack coat with (viscosity grade paving bitumen of grade vg-10) @ 10.0 kg per 10 sqm of surface putting in & including premixed bituminous macadam, well rammed and sealed with binder 9.80 kg/sqm, blinded with 0.09 cum of stone chippings, 6.3mm size and again well rammed, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and using with 8 to 12 tonne power roller (including supply of premixed macadam, binder and chippings),completed all as specified and as directed., premix bituminous macadam laid / rolled and compacted using 8 to 12 tonne power roller to required gradient and camber, with broken stone graded aggregate with 4% of paving bitumen binder of viscosity grade vg-30 grade by weight of toal mix (consolidated thickness 75mm or less) completed all as specified and as directed., m&l providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completed all as specified and as directed., m&l for marking lines 2.5 mm thick, dashes arrows etc of any description n. exc 10cm width/girth on road surface using hot applied thermo plastic road marking paint of approved colour confirming to bs-3262-1989 with special applicator machine all as per manufacturere instruction completed all as specified and as directed., supply and fix solar cat eye (green/red) aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4v/ 0.3 watt one ni-ed rechargeable battery (1.2v/ 1600ma) consisting of super bright led with 10,000 to 18,000 mcd completed as per manufactures instructions etc completed all as specified and as directed., supply and fixing metal tubular dealineator made out of abs round body fitted with 2 nos 65 mm dia highly reflective reflectors made out of and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in pcc 1:2:4 (150x150x300mm) type b1 complete all as specified and directed, s&f manufacturing, supplying and fixing retro reflective mandatory/ regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered wi

Central Government/Public Sector

CTN :45375193 Due date: 20 Jun, 202620 Jun, 2026 NA
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo

CTN :45138827 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For bid to ras supply of s and f of ring main system for wss - supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supply and fix valve reflux with by pass arrangement 100mm 4 inches dia , supply and fix foot valve confirming to is 4038 100mm 4 inches dia , supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia , supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia , supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core , supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc , supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc , supply install test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc , supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in ) /bid number : gem/2026/b/7514655 * /dated: 08-05-2026 & & / bid document 1 / 21 & & ' ' /item category cast iron water supply mains , excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc , returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge , removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc , boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special , di or ci special such as tee bend collar tail piece and other fitting as required , earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode , demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness , m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness , m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc , m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame

CTN :45160678 Due date: 18 Jun, 202618 Jun, 2026 25.00 Lacs
Tender For corrigendum : maintenance and repair of road/path by providing cement concrete tiles, retaining walls, parapets walls, railings, chain link fencing etc.

CTN :45160679 Due date: 18 Jun, 202618 Jun, 2026 15.00 Lacs
Tender For corrigendum : maintenance and repair of road/path by providing cement concrete interlocking paver etc.
 Loading, Please wait...

Connect us via What's Up