Get complete information related to latest Rod Heater Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rod Heater Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rod Heater Repair Tenders.
Tender For corrigendum : repair / replacement of meter distribution panel at c connected submains and internal wiring ceiling fan, wall fans and electric and solar water heater with connected accessories in otm accn in grc under ge kamptee.
Tender For corrigendum : repair/replacment of meter distibution panel at cariappa vihar, micts, 414 asc bn and ftp, r line connected submains and internal wring ceiling fan, exhaust fan, wall fans and electric and solar water heater with connected -- under ge kamptee.
Tender For purchase of spares for alikraft make chimney elevator from m/s alikraft engineers pvt ltd, vadodara for u 5 & 6, csctpp, chhabra - power contactor ac-4 duty, model-3tf3s, thermal over load relay (16-25) a, auxillary contactor: 6 a, 110 vac, electronic timer:0-30 sec, p.b.: 022.5mm 2no+2nc yellow/green, p.b.: 030mm ino+1nc red-stay put type, votage transformer 400va, 0-415/0-12-19-230v, tone frequency receiver, batiery charger, single phasing protection relay, neutral link: 63a/5a, chance over switch: 63 a, hour meter: 230 vac, 50 hz, r.y.b indicating lamps, selector switch: 2 position, insp/normal, kaycee/siemens, thermostat: 00-60c, panel space heater: 40w, receptacle: sa, brake motor: 12.5 kw, 415 v, rectifier 1/p-415 v. o/p (156, 22, 135) vdc, 3 phase limit switch: 415 vac, pin ion m8, c/\ole tbolley guide boller, cage guide rolleh, counter holler, sew brake assambly, teflon roller with bush, coupling spider, wranch for guide rooler, cable guide pu springe rubber, oil sea l 45x62xlo, o ring (3x2sand 3x90, sew motor brake liner, drive fx2000 18kw,440v ac
Tender For supply electrical material for electrical department m.c. ambajogai dist beed - 1.5mm2 1/18 pvc wire 91 mtr, 2.5mm2 1/18 pvc wire 91 mtr, casing caping, 8 way switch board with cover plate, 16 way switch board with cover plate, 6 a 10 a switch, 16 a switch, ceiling fan 1400 mm, cabin fan 400 mm, cooler 55 ltr, 1.5 ton ac with compresser unit, electronic ding dong bell, 18 watt led bulp, 20 watt tube light with all fitting acessaroes, 3 pin plug 16 a, 3 pin plug 6 a, 2 pin socket 6 a, 3 pin socket, fan regulator, 36 watt tube light, condenser 2.5 micro farad, backlit type pendent holder, ding dong bell, batten holder for lamp fitting, 2 pole mcb 16 a-32 a, main switch box with 3 cutouts 16 a each, ceiling rose, cutout kitkat fuse 32 a, electrical insulation tape (box), gi wire, stay wire with stay set, rain coat, gum boot, hexa blade, earthing rod / plate, tube light inbuilt invertor 20 watt, exhaust fan 900 rpm, electric extension board 16a/ 20a with 5 socket, electric extension board 6 a with 4 socket, 2.5 mm2 al. service wire, 4 mm2 al. service wire, 6 mm2 al. service wire, 10 mm2 al. service wire, bell switch, 2 core 6mm2 armad cable, 4 core 10mm2 armad cable, 4 core 16mm2 armad cable, 4 core 25mm2 armad cable, 4 core 35mm2 armad cable, 4 core 50mm2 armad cable, 4 core 70mm2 armad cable, flood light 100 watt, flood light 50 watt, flood light 24 watt, flood light 200 watt, spmcb 32 a, kitkat 63 a, 10/16/25 mm2 al. lugs, 35 sqmm cu. lugs, 18 25 watt led street light, 46-100 watt led street light, 26 45 watt led street light, water heater 1200 watt, distill water for battery, psc pole, hand glous, led bulp up to 10 watt, incandescent lamp up to 100 watt, 200 watt incandescent lamp, soldering machine, driver for outdoor led up to 50 watt, driver for outdoor led up to 55-100 watt, driver for outdoor led up to 105-200 watt, ant conductor for street light phase with gi wire, gnat conductor for neutral, panel box iron body (for meter, timer, contactor, cutout setup, shackle lt insulator, pcb for led lights up to 50 watt, pcb for led lights up to 55-100 watt, electric flyer, electronic type cordless call bell, rubber patch, iron / still lock with chain, screw driver, spanner, cutter, street light bracket 40 mm dia. b class gi pipe 1 mtr in length with clamp & nut bolts, kitkat 100 a, tong tester, drilling machine, torch light with cells, 2500 va digital pur sine vave inverter single phase 230 volts 50 hz, 12 v / 180 ah tubuler battery, 35 sqmm single core copper wire, gi pipe a class 25 mm dia., street light timer, street light contactor 70 am, rsj pole 8 mtr, fan huke with fan clamp
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For bid to ras corrigendum : supply of lo centrifuge - lub oil centrifuge with heater control panel sludge tank feed pump sludge discharge pump and all accessories , flow meter for treated oil , gauge assembly board with pressure or compound gauge pipes isolation cocks etc , loose fittings and instrumentation as applicable , shock mounts with center and side holding down fasteners , flexible pipes bellows for all equipment interface with external loose supplied system , electrical items for connectorisation termination that is cable gland lugs etc , first submission of binding drawing , documentation hard copy , documentation soft copy , ietm documentation , service of service engineer 10 mandays with 3 sorties per equipment and there is 4 eqpt , preservation de preservatives , commissioning spares , onboard spares , standard special tools , training training material , service of service engineer 10 mandays with 3 sorties per equipment and there are 3 eqpt
Tender For supply of printer services - repair replace of control panel pickup assy motor pcb assy power supply fuser heater and service of hp laser jet pro mfp m126nw , repair replace of formatter board belt drive gear ccd scanner cable ccd assy and servicing of hp laser jet m1136 mfp , repair replace of power supply with cable set laser scanner unit paper pickup roller and servicing of hp laser jet m202n printer , repair replace of formatter board power supply toner drive gear serving of brother hl l2361dn printer , repair replace of timming belt ccd scanner assy power supply with cable set printer head and servicing of the hp jet pro 6230 color printer