Tender For corrigendum : supply of posterior vitrectomy machine d d- high end posterior vitrectomy machine with phaco emulsification , phaco handpiece , irrigation and aspiration probe , phaco tips , phaco sleeves , diathermy forceps , endo diathermy handpiece , endo diathermy tip 23g , endo diathermy tip 25g , fragmatome tip , key for phaco tips , test chambers for phaco , drainage bag , silicone oil injection and extraction set 23g , silicone oil injection and extraction set 25 g , vitrectomy pack 23g , vitrectomy pack 25g , vitrectomy pack 27g , air compressor unit , balanced salt solution or bss pack , 6 mm infusion cannula
Tender For supply of flat bottom boiling flask 250 ml for ongc , burette stand with two clamp for ongc , beaker for urea adduction for ongc , soxhlet extraction unit medium for ongc , soxhlet extraction unit large for ongc , glass rods, diameter- 3mm for ongc , glass dropper with rubber bulb for ongc , chromatograph column glass for ongc , chromatograph column glass, outer diameter- 11mm for ongc
Tender For supply of supply instll commissioning of machinery equipment for passion fruit proc unit on turnkey basis : : - raw water transfer pump , mineral dosing system , ro water treatment , pulping section , ss heating kettles , cold storage , sugar syrup preparation , sugar syrup storage tank , air compressor , dumping tank , blending tank , homogenizer , storage tank , pasteurizer , automatic rinsing , pet bottle blowing , date or batch coding , l shaped conveyor , box packing table , ss plumbing line , steam boiler , electrical control panel , seed oil extraction unit , quality testing laboratory set , effluent treatment plant , clean in place cip system , cooling tower
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20