Get complete information related to latest Rolling Mill Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rolling Mill Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rolling Mill Spares Tenders.
Tender For tender for supply of erection and fabrication work b c c - juice/water scale ke weight channel bed mein se gale/kamzor channel ko kaatkar hatana. poorvanusar naya banakar lagana evam trial dena. , juice weighing scale ke filling tank ke rods ki kamzor/gali guides ko naya banakar lagana. , juice. maceration water evam final molasses ke weighing scale tank ke gale/kamzor bottom cone ko kaatkar purane anusar naya bottom cone lagana va poorn trial dena. , juice weighing system ke measured juice receiving tank ki gali/kamzor bottom evam side plates ko kaatkar hatana evam nirdeshanusar purani/nai plate lagakar leak.proof trial dena. , raw juice pump par lage catcher ko kaatkar hatana tatha naya catcher fabricate kar yathasthan lagakar samast connection poorv ki bhanti karna evam leak.proof trial dena. , pan. quad body evam vapour line juice heaters ki hydraulic testing ke liye inlet evam outlet ke vapour pipes mein cutting karke plate ke blind weld karna tatha hydraulic uparant blind kaatkar hatana evam vapour pipe ko punah andar va bahar se leak.proof weld karna. , semi kestner. vapour cell. quad body juice heater. vapour line juice heater ke condensate bottles tatha syrup receiving bottles ke cells ko kaatkar ceiling baffle plate ke kamzor hisse. bottom plate ke kamzor hisse athva cell ke kamzor hisse ko badalkar condensate bottles/syrup receiving bottles ki vanchhit marammat kar jal bharav parikshan dena. , juice heater mein lage ayatakaar juice entry box ko dismantle karna. gale/kamzor charon nipples badalna. double beat valves ki fitting hetu dono flanges lagana. box ki marammat kar box fit karna evam double beat valve fit karke leak.proof parikshan dena. , sabhi juice heaters ki gali hui sampoorn partition plate ko kaatkar bahar nikalna va nai 8/10 mm plate lagakar gili hui ring ko leak.proof welding karna tatha lagi hui tubes ko bachakar santoshjanak trial dena. , juice heaters mein dono taraf partition plate ki kamzor m.s. strip ko dismantle karna. kate face par grinding kar nai 25 mm x 5 mm ki m.s. strip banakar lagana evam rubber fit karna. , juice sulphiter ke recovery tower ke gale/kamzor bottom cone ko kaatkar 10/12 mm moti m.s. plate se sample anusar naya cone fabricate kar yathasthan fit kar leak.proof welding karna. , juice sulphiter ke base ke charon side ke gale/kamzor horizontal beams ki vanchhit strengthening hetu unke andar 12 mm moti plate lagakar majbooti pradan karna. , juice/syrup sulphiter ke kamzor bottom cones evam top cones ko dismantle kar sample anusar naya banakar fit karna. tatha andar va bahar se leak.proof welding kar santoshjanak jal bharav evam trial dena. , syrup sulphiter ke tower ki gali/kamzor baffle plates/jaliyon ko bahar nikalna. vanchhit marammat kar yathasthan fit kar leak.proof trial dena. , syrup pump se syrup sulphiter tak dono pumps ki delivery ki dono lines ko neeche utarkar garam karke. bhali bhanti safai karna. gali hui pipe line badalkar valve. bend. nipple ityadi lagakar punah lines ko fit karna evam leak.proof trial dena. , syrup/juice sulphiter ke upar lage recovery tower ko utarkar gali shell ko nirdeshanusar nai/purani plate se shell taiyar kar fit karna evam tower ko punah yathasthan lagakar leak.proof trial dena. , juice/syrup sulphiter/clarifier ke kamzor shell ke kamzor bhag ko kaatkar hatana. nirdeshanusar nai/purani 10/12 mm plate se banakar yathasthan lagakar andar va bahar se leak.proof welding kar trial dena. , sulphur bhatti (juice/syrup) ke gale/kamzor secondary gas cooler ko kaatkar hatana. 10/12 mm moti plate se purane ke anusar naya cooler fabricate kar yathasthan fit kar samast connection poorv ki bhanti kar leak.proof gas trial dena. , sulphur bhatti station par juice/syrup hetu sthapit sulphur bhattiyon ke gas coolers ke gale/kamzor cooling pipes ko kaatkar hatana. purane anusar naye pipes taiyar kar poorv ki bhanti fit kar leak.proof trial dena. , sulphur bhattiyon ke gale gas headers ko kaatkar hatana. purane anusar naye headers taiyar kar lagana. , sulphu
Tender For supply of analysed oil samples and disposal record , boiler water analysis record , calibration record, carbon analyzer , calibration record, flame aas , calibration record, analytical balance , calibration record, mass spectrometer , calibration record, weight box, e1 , calibration record, gc, mp , calibration record, ion chromatograph , calibration record, kf titrator , calibration record, ftir , calibration record, conductivity meter , cooling water analysis record, landscape , calibration record, density meter, dma 58 , density meter calibration record , dissolved oxygen record , dm plant cpp analysis record , dm plant analysis record , calibration record, flame photo meter , calibration record, h2s gas bombs, ss sample containers , lab effluents discharge , monthly report for trade effluents , na2so4, recovery analysis record , ng heavy water analysis record , non returnable material dispatch record , oxygen 18 sample analysis record , observation book for kmno4 demand , pc and al analyzed samples disposal record , calibration record, ph meter , process liquids analysis record , raw material analysis record, h2so4 , raw material analysis record, naoh , raw material analysis record, na2s and nahs , raw material analysis record, hci , raw material analysis record, alum , raw material analysis record, libr , raw water treatment plant analysis record , rcu gas analysis record , seal and lube oils analysis record , system and purge gas analysis record , calibration record, turbidity meter , uv visible observation book , waste stripper average record , xu samples analysis record , bottom ash analysis record , boiler feed, dissolved oxygen, iron and copper record , flue gas analysis record , scc ltd. coal analysis record , spm analysis record , single ruled book
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r
Tender For procurement of consumable items required for upcoming unit 4 overhauling for ahp-mm-ii,sgtpp. - procurement of consumable items required for upcoming unit-4 overhauling for ahp-mm-ii,sgtpp., ball valve 25nb ss, elbow,ms,25nb size,both side thread $for water line application, elbow,ms,40nb size,both side thread $for water line application, elbow,ms,50nb size,both side thread $for water line application, bend 100nb x90 deg (fly ash system),ms # ( thickness: 9.52mm ), bend,ms,250mm x 250mm x 90deg ( 9.52mm thickness ), anabond 666 size 310 gm #, nipple (bsp),ms 15 nb,100 mm long, nipple,ms,40nb size,lgth:100mm $for water line application both side 200mm thread, nipple,ms,50nb size,lgth:100mm $for water line application both side 200mm thread, felxible rubber hose,1/2x1 mtr long, bend,90deg,seamless,40nb,sch-40,ss-316 for alum dosing system at ptp, bend ss 90deg seamless 15nb r=1.5d for air line mat: sa 403 wp 304, wall thick: sch40, nrv,non return valve:15mm 1/2in #, flange,40nb,ms,asa150#std, flange,80nb,ms,asa150#std, ms flange, size: 150 nb, ms flange, size: 250 nb class: 150 dimension and drill as per ansi b 16.5, ms flange, size: 200 nb class: 150 dimension and drill as per ansi b 16.5, ms flange, size: 100 nb class: 150 dimension and drill as per ansi b 16.5, socket with plug (s.i) sz. 15mm, bend,ms,200 mm x 200 mm x 90 deg for ash water line ( 9.52mm thickness ), gasket,asbestos,style 11,t2mm # ( make: spitmann/champion,+10 kg clearance in quantity. ), asbestos gasket style 11 size 3mm thk # make: champion/spitmaan, oil gasket style 59 nonmetalic th 1mm ( make: spitmann/champion,+10 kg clearance in quantity ), ptfe gland packing-1094,size-16 mm, neoprene rubber sheet # size,1m x 2m x 3 mm thick, inspection window glass,clinker grinder $for bottom ash hopper ( shall consist of following ;- a) glass 225 mm dia and 16 mm thk high temperature tuffen glasss - 1 no b) special silicon gasket - 2 nos. c) special rubber asbestos gasket - 1 nos ), male hex nipple male hex nipple 1/2" npt (m) x 1/2" npt (m) moc: ss316, gasket,asbestos jointing sheet,t-1mm # gasket-asbestos jointing sheet style-59 brand-champion/spitman thickness-1 mm ( "sheet size: 2000x1500 mm thickness: 1 mm maximum pressure: 150 ksc. maximum temperature: 550 degc density: 1.9-2.2 g/cc tensile strength: 280 ksc compressibility: 7-10.5% gas permeability: (>)>0.5 cc/min stress relaxation: 300 ksc recovery: >=50% ignition loss: =(>)>25% compliance: is 2712. tolerance: 10% (in weight)" champion brand style 59 indenting department:bm-70,tm-100, ahm-50,chmws-50. ), gasket,sheet,caf,style-59,0.5mm thick # sheet,caf gasket spitmaan style-59 size:0.5mm thick,colour black,media: oil grease etc max temp: 550 deg c max pressure: 150 kg/sq cm specification: is2712-1998 grade is 2712-1979 grade o/i,is 2712-1971 grade a/o british bs 1832-1972 ( make-spitmann ), bend,ms,150mm x 150mm x 90deg ( thickness 9.52 mm ), bend 65nb x90 deg,thk-9.5mm,ms for fly ash system #, bend 80nb x90 deg,thk-9.5mm,ms for fly ash system #, socket,1/2 inch (f),thread,ss304 1/2 inch (f) all thread socket,ss 304# for impulse line connection sgtpp1 ( with both ends internal threaded for water line application wp-20ksc moc-ss 304,grade-heavy duty ), nipple,40nb size,lgth:100mm for seal line application (vaccum& slurry line) , moc: ss304, both side thread length 35mm. ( both side thread length 35mm. )
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref