Get complete information related to latest Rotary Holder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotary Holder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotary Holder Tenders.
Tender For corrigendum : supply of roof line insulator to clw specn.no. clw/es/ac/ 1-1 alt-l and clw drg. no: clw/es/sk-2/ac/i- 1 alt-l. [ warranty period: 30 months after the date of delivery ] ]
Tender For auction sale of others - u/s scrap condemned line insulator, panto mounting ins., vcb insulator, et ins. all size ferrous ceramic & porcelain type solid and broken condition released from electric locomotive. qty.-36.810mt. for stock holder sse/s/tkd. ss-11 no-sse/s/tkd/35/26-27/05 date 24.04.2026. ds-8 no. 015066 dt.24.04.2026. lot should be sold on as is where is basis. purchasers are requested to see the lot/site and approchable road before bidding. no claim will be entertained after sale of lot. the stock holder is responsible for any alteration, deletion & variation in the lot or in weighment or tempering with the lot will be solely responsibility of stock holder after joint inspection, if any found subsequently. bidders must submit the fixation of the delivery date through the ireps e-auction sale module at least 7 days prior to the delivery date. delivery will be given by actual weight on government approved dharam kanta only. material are lying in delhi (tkd) state.
Tender For establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - transmission line; defectivedisc from the porcelain insulator strings; as per bid document
Tender For supply of roof line insulator to clw spec. no.- spec: clw-es-ac-i-1 alt.l,& drawing no. clw/es/sk-2/ac/i-1/ l [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of panto foot(mounting) insulator for locos & emus/memu and roof line insulator for emus/memu. specn: clw spec/drg no.clw/es/ac/i-1/h,clw/es/sk-4/ac/i-1/h. [ warranty period: 30 months after the date of delivery ] ]
Tender For stage contract for carrying out various electrical maintenance works including sitc, itc of various line materials and distribution substations and dismantling of existing deteriorated out lived electrical infrastructure for the year 2026-27 under th - supply, installation, testing and commissioning of 3-phase 25 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 63 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 100 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 200 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, supply, installation, testing and commissioning of, 3-phase 250 kva distribution transformers with bimetallic terminal connectors energy level-2, (al wound ), and with lv cable box having detachable aluminium gland plate, sitc of 11 mtr long st poles 410, sp-56 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 9 mtr long st poles 410, sp-33 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long st poles 410, sp-15 including transportation, manual, mechanical carriage, delivery at site with pit excavation, refilling the pit with soil, boulders., sitc of 8 mtr long pcc poles including manual, mechanical carriage, excavation of pole pits with inscription of permenent marking on each pole "name of scheme-2019-20/xx" (xxx mean pole numbers say 01,02...) in white paint in backgound of green paint at conspicious place, providing & fixing of pole earthing as per rec standard as per j-1 (spiral earthing) drawing, supply,fixing of spike earthing rod 20mm 2,5 mtr long with gi strip (25x3)mm, supply and painting of each pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint), providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of galvanized iron of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing, errection, testing & commissioning of channel cross arms, v-cross arms, sub-station channels & angle iron braces, transformer beltings, including back clamps for fixing cross arms etc fabricated out of mild steel of different sizes (rec standard) & to be fixed with gi nuts & bolts and washers., providing & and fixing of 11 kv pin insulators (polymer) with pins ( 5 kn), providing & fixing of 11 kv, g.o ab switch , 3-phase, 200a (09 insulator post type) with arragement for pad locks & operating rod . the operating rod should be g.i pipe (b-class) of 25 mm dia of requisite length., providing & fixing of 11 kv horn, gap fuse 3-phase 100a, providing & fixing of 11kv link set 3-phase, 200 a (station type), sitc of 11kv isolator double break, 3-pole, 630 amps, horizontal mounting type , with earth switch, providing & fixing supply and installation of gapless surge arrestor,9 kv,10 ka, la with (polymer) housing, station type, providing & fixing of lt fuse set of suitable capacity for 63kva,100kva,200kva (as per tender drawing attached), providing & fixing of 11 kv disc insulators (polymer) complete with fitting( 45 kn), providi