Get complete information related to latest Rotating Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rotating Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rotating Light Tenders.
Tender For corrigendum : supply of spare of lt vfd at hurl sindri on oem basis - dual temperature transmitter, filter capacitor for sine wave filter, current transformer ratio - 100/1a, vfd control device, vfd power device, hrc fuse link bs type, fuse holders & isolating link, hrc fuse bs type, fuse-link rating-80a, ac 690 v., fuse base nh din type, "6"" output filter ral 7035 size 6 incfan failure and temp detection unitiop (intelligent operator panel)power contactor rating-45a, 230v ac", "sine wave filter reactor rating -22kwpanel fanmulti-function meter (mfm)32-50 a, thermal overload relay""", circuit breaker with electronic trip, panel door mounted rotary op. handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, 5a, d series ac drm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs-4-20ma, motor restart timer, green push button & contact block, red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block., yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For supply of "operation of baggage handling system ( both arrival and departure ) by engaging following minimum man power. a) electrician cum operator/ technician - skilled - 04 nos ( all days including weekly offs & holidays).b) skilled - 01 no. for data entry & other miscellaneous work (in general shift for six days in a week )note- contractor has to provide reliever on weekly offs / holidays of above required staffs except for sl. no. b) ", supply of red outer lens for rwy end light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of green outer lens for rwy threshold light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of yellow filter for runway edge light suitable for existing airfield ground lighting system (agl) complete as required .( existing light fixture is of vardhman make ), supply of 200w, 6.6/6.6a halogen lamp pk30d(64382 hlx-c) make - osram or equivalent suitable for existing agl/ cat-i fittings complete as required ., supply of isolating transformer of 200 watts, 6.6a/6.6a, 5kv, 50 hz suitable for existing agl/cat-i light fixtures complete as required. , supply of wind socks (cloth) for wdi(white/red) suitable for existing sgs make wind sock., supply of 360 degree outer clear lens for runway edge light fitting suitable for existing light fixture of vardhman make., supply of clear spreader lens for approach light fitting suitable for existing light fixture of vardhman make., supply of clear lens for papi suitable for existing papi system of vardhman make., supply of 2cx 4 sqmm. annealed tinned copper conductor pvc insulated pvc sheathed unarmoured flexible afl secondary lead up to voltage garde 1.1 kv conforming to relevant is up to date ammendment complete as required., supply of minimum 9 w led type aviation obstruction light in red colour having die-cast aluminum housing with red polycarbonate dome for better illumination, integral driver, ingress protection - ip65 (make- bajaj or equivalent as approved by eic), supply of 30 w movable led flood light (yellow colour) (make - philips , type - bvp102 30 or equivalent) complete as required at site., supply of 150 a, 1000v, 50 sq. mm terminal block suitable for mounting on din rail suitable for existing panel complete as required at site., supply of led driver of 80w, 25 v suitable for existing airfield signage board (make-electrosystem) installed in operational area complete as required at site., supply of 15 w led suitable for existing taxiway light fitting of vardhman make complete as required at site., supply of electronic driver suitable for existing 15 w led taxiway light fitting of vardhman make complete as required at site., supply of mnx 70 type 3 pole power contactor having ac-3 duty, 70a rating, ac1 -100 a rating, coil voltage- 230v ac, suitable for lighting switching applications, panel mounting, conforming to conforming to is/iec 60947-4-1 etc. complete as required., supply of isi marked, heavy duty, rigid pvc conduit, size- 25 mm dia, confirming to is 9537 (part 3) complete as required at site., supply of national flag of size 9144 mm x 6096 mm as per bis specification no is 1-1968 latest complete as required at site. , "supply of 18 mtr length tri-colour led rope light having transparent pvc type body material, ip65 protection, smd led strip as per lm 80/is16106, conforming to is 10322 and suitable for operation on 240 v, 50 hz single phase power supply complete as and when required. (make-philips/halonix/crompton/bajaj/osram) ", providing and fixing of temporary decorative lighting in tri-colors of national flag with led series lighting at terminal building and main gate of ayodhya airport having uniform spacing of between two rows is not to be more than 0.30 mtr for a continious three days on the occassions of republic day/independence day/diwali/new year including
Tender For tender for supply of sensor water temperature , lamp assy fornt fog , filter assembly fuel , mirrror assy out rear view rh , lens tail stop , handle lock , arm assy wiper rh , belt water pump , cap , assy wiper blade , cartridge , assy rear view mirror out side , indicator light , minor rep kit for clutch m/cyl consistin , electronic flasher kit , minor repair kit for m/cyl consisting of , door lock front lh , bearing roller taper
Tender For corrigendum : tender for supply of fuse 15a fitting for hrc , hrc fuse fitting with fuse link rated 2a , hrc fuse link rated 80a , tp mccb rated 250a(nsx250b) , d w transformer class f insulation380 127v , 300va 1ph , 50hz , fuse link 2amps , cam type switch with 2 pole , 2 way on off rated 6a (s6-61038 , aux contactor 10a , 24v dc coil with 2 no+2nc (3th30122obb4) , d.p miniature circuit breaker rated 25a , breaker circuit moulded case 300a with rear connec , power contractor 16a , 415v operating coil 1no+1nc , ring type copper lugs 95 e 12 , add on 1no contact , on delay electronic timer ac 110-240v having range 1-30s , buzzer cum flasher 230v , ac , load sharing unit , illuminated pushbutton integral led 230v green , pneumatic on delay timer range 0.1-30s with 1no + 1nc , triple pole miniature circuit breaker rated 63a , indicating lamp integral led white colour , 230v ac , indicating lamp integral led green colour , 230v ac , triple pole mccb 200a , shrouded pushbutton yellow colour with 1no contact , contactor rated 80a , 24v dc coil with 1no+1nc , kilowattmeter 0-500kw 3 wire 2 elements , ammeter 0-600a , ctr 600/5a , size 96x96mm 240 deg scale , hrc fuse fitting with fuse link rated 4amps , nas01-0011tb hdd , cam type single pole on-off switch 10amps , 1s160 , reverse power relay 415 480v , l-l-6a , type t2000-01-20 , transformer 380/220v/110/24v/1000va , single pole on-off cam switch 10amps , 20 kva radio transformer , fuse base 20a , contactor 70a t.p. (contactor kit) , contactor 205a-24v dc coil wtg 2 no + 2nc(3tf53-02-ode4) , voltmeter 0-150v , 400hz acc class 1 , 96x96 rm at 115v (sif-96) , indicating lamp integral led red colour , 230v ac , ammeter rated 0-400a , ctr 400/5a , size 96x96mm-smi-96
Tender For tender for supply of cable 3250 mm , engine cranking lever , flexible delivery tube type-98 , hand lamp insp lamp , electric horn 24v dc , filter insert , hose radiator outlet , repair kit valve , water strip door , rotatinglight , gasket thermostat , plug for oil drain , regulator vehicle window , brass nozzle 40mm with male coupling , door lock front rh , pressure protection valve , ball bearing , material tube repair hot seal patch , grease gun , nut m8 , pad , lock side window lh , wedge , nut
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required