Web Analytics Made Easy - StatCounter

Roughness Tester Tenders

Get complete information related to latest Roughness Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Roughness Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Roughness Tester Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45313570 Due date: 09 Jun, 202609 Jun, 2026 NA
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - s/i/t/c of new 80 hp vt pump set, supplying,installation,testing and commissioning of vt pumpset (confirming to is1710:2021 standards) with 35 ft suitable size ms column pipe assembly in random length of 5 ft.(make-jyoti/wpil/kirloskar) with ss/bronze impeller capable to discharge 216 m3/h against a total head of 68m coupled with vertical solid shaft tefc ie3,ip55 type squirrel cage induction motor (make-siemens/crompton/abb) operating on 3 phase 50 hz,415v+- 10% supply and having speed 1400-1500 rpm (bhp of motor should be 10% more than that of pumpset including cost pof supplying,fitting and fixing of all required accessories, repairing of 80 hp vt pump set at raw water, supplying all labour tools and tackles for taking out the 40hp vt pump set with bowl assembly, column pipe and line shaft etc., cost towards dismantling of complete bowl assembly., cost towards repairing and fitting the parts of vt pumpset as per requirement (works as complete overhauling of the pump) such as:-1.machining/lathe work 2.changing ss top shaft,line shaft(2 nos of 5 feet) of and bottom shaft2.repairing of bowl assembly and impleller3.supplying and fitting c.l spider bearing with rubber cut less bush-4nos4.supplying and fitting of worn-out nut-bolts,bolt-nut washer,gland body bush machining,other machining works,etc as per requirement, complete assembling the pump set and lowering including supplying all petty materials., cost for supplying and installation of required accesories for repair and maintenance of motor control panel such as:-150 amp contactor-2 no (for 1 no starter)160 amp,breaking capacity -36ka mccb 1 no56-90 a electronic overload relay-2 nostimer-2 nosvolt meter 1 nosamp motor 1 nospilot lamp 6 nosselector switch 4 nossingle phase preventer 2 nos[ all accessories of reputed make]with complete internal wiring with suitable size of copper wire and testing on load., repairing of 30hp c/f pump sets at clear water, cost for dismantling of 30 hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb - 50 amp,25ka,3pole-2 nos (for motor backup protection),mccb -100 amp,50ka,3pole-1 no (main mccb)2.overload relay 26-40 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required, repairing of 15hp c/f pump sets at clear water, cost for dismantling of 15hp c/f and pump inspection,changing of its damaged parts such as:-key-01 no, gland tightner -1 set, gland tightner stud-2 nos, c.i bearing housing with cap -1 set, ball bearing 6306 (skf)-2 nos, grease, gland packing,maching of the pump parts as per required etc all complete and testing on load etc., cost towards complete repairing of motor control panel starter 30hp cf pump set opening and changing of damaged parts such as 1.mccb -25 amp,15ka,3pole-2 nos (for motor backup protection),mccb -50 amp,25ka,3pole-1 no (main mccb)2.overload relay 20-25 amp-1no3.star delta timer-1no4.digital volt meter,ampere meter,three pahse indicator lamp,push button on/off,on/off/trip indicator,wiring,etc as per required

Central Government/Public Sector

CTN :44914043 Due date: 29 May, 202629 May, 2026 NA
Tender For bid to ras bid to ras corrigendum : supply of electronic load

CTN :45331370 Due date: 10 Jun, 202610 Jun, 2026 NA
Tender For supply of prodigit electronic load module

Central Government And Public Sector

CTN :45333893 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For supply of portable surface roughness tester (q3)

Central Government/Public Sector

CTN :45303150 Due date: 02 Jun, 202602 Jun, 2026 24.38 Lacs
Tender For supply of auxiliary transformer prim 110 220v, part no. mlpat209 , delay timer electronic 0 - 30 s, part no. mlpbch210 , protection relay for motor, part no. mlprm100 , brass cable gland, part no. mlpbcg107 , ammeter , analogue, 96 sq mm, part no. mlpaa111 , voltmeter , analogue ,72 sq mm, part no. mlpbr113 , lamp red 110 v ac, part no. mlpboskr120 , lamp yellow 110 v ac, part no. mlpbosky121 , lamp green 110 v ac, part no. mlpboskg122 , push button actuator with 1 no 1nc, part no. mlpbovsne127 , ct,100 5 double ratio, part no. mlprcct159 , ct,75 5 double ratio, part no. mlprcct160 , vacuum bottle 1250 amp, part no. mluvb207 , master trip relay, part no. mlumt212 , pneumatic type on delay timer ,0-30 sec, part no. mlptimer144 , earth leakage relay, part no. mlpelm148 , isolator , off load, part no. mlpkhti150 , bridge rectifier 10 amp 110 v ac to dc, part no. mlpbrd157 , yellow push button, part no. mlpbov171 , red push button, part no. mlpbov172 , green push button, part no. mlpbov173 , numerical overcurrent relay, part no. mlpnor181 , vcum cntctr asly,400a,6.6kv,85-230vac dc, part no. mlpasras136 , pt fuse, f 6.6kv 7.2kv,3.15a, part no. mlptfs102 , under and over voltage relay, part no. mluov218 ) /bid number : gem/2026/b/7564535 * /dated: 23-05-2026 & & / bid document 1 / 27

Central Government/Public Sector

CTN :45193563 Due date: 05 Jun, 202605 Jun, 2026 NA
Tender For upgradation of railway owned electronic in-motion weighbridges (eimwb) for wheel wise load weighment at rpm & abu by oem.

Central Government / Public Sector

CTN :45152644 Due date: 02 Jun, 202602 Jun, 2026 NA
Tender For up-gradation with wheel wise load measurement system of electronic in motion weigh bridge (eimwb) at hnd with an implementation period of 02 months and comprehensive annual maintenance contract (camc) for a period of 04 years by oem m/s rice lake, chennai.

CTN :45169227 Due date: 28 May, 202628 May, 2026 NA
Tender For corrigendum : procurement of different consumable items and spares for overhauling of unit 5 and unit 3 under em iph dept bktpp - thinner -234 for varnish, varnish bectol red, varnish bectol grey, silastic 732 rtv (300gm bottle), jointing sheet,asbestos,2000x1500x3 mm # jointing sheet,non-metallic compressed asbestos fibre to withstand 550 degree c,150 ksc is code 2712/9.8 grade w/1,size-2000?1500? 3 mm, jointing sheet caf style 59 oil gasket,, jointing sheet,asbestos,2000x1500x1 mm # jointing sheet non-metallic compressed asbestos fibre to withstand 550 degree c,150 ksc is code 2712/9.8 grade 0/1 size-2000?1500? 1 mm, paint synthetic enamel black, paint synthetic enamel smoke gray, acetone, locktite,406,401, hardner,hy 840 for eco-ash wa drg.no.: hw5520073007, resin,cy 205 $for wound stator assy part no.01350801003122, paint remover,locktite,sf-790 for generator, diluent c,drg:5670269,item no:134 generator, mcb,4 pole,63a,top hat rail mounted # 240/415v ac, o/l relay 415v ac,38.0a - 50.0a reference: lr1-d63357,tc, hose ?" dia.430 mm length # hose ?" dia.430 mm length with fittings grade ph8 design pr.345 bar,insulation resistance 15 megaohms for jacking of 210 mw bhel g enerator shaft, hose 3/8" dia. 430 mm length # with fittings grade ph8,design pr. 276 bar,insulation resistance 15 megaohms# for jacking of 210 mw bhel generator shaft, o/l relay 415v ac mn-2 ss94141 3-5a,l&t, o/l relay 415v ac mn-2 9-15a,l&t cat no. ss94114, contactor,power,coil:240 vac,2no+2nc,32a # siemens auxiliary contact-2no+2nc,coil voltage: 240vac,50hz,type: 3tf34 00-0au0,siemens, mcb,3p+1n,16a,top hat rail mounted # 415v ac,9ka, valve gate gm nb-25mm #, ht rubber tape, gear box assembly complete # paharpur cooling towers model: 10p for stage-ii cooling tower (type-6kf ), switch,hp & lp combine cut-out,kp-15 for ac plant, overload relay,18.0-25.0a,415v ac # type:lr1d-25-322 tc, power contactor lc1d80, relay,electronic,over current,0.5~80a 3dm2-wrduwz schneider operating voltage - 100 to 240vac/dc 50/60hz, aux. contact- ol (1nc+1no), al (1no), over load current setting range - 0.5 a to 80a, mpcb,o/l 56-8oa,s/c 15ka # type:gv3me80 schneider-electric, contactor,415v ac,32a,coil 240v ac for power contactor tc, relay, o/l, 415vac, 0.63-1.0a 3ua-5000-0j siemens, thermal overload relay lrd-32 23-32a lad7b106, mcb,3pole,c100, mcb,80a 415vac 3-pole,c-curve,10ka, varnish elmoluft, strainer,screen oil,compressor js 83 af $for ac plant for compressor model: js 83 af,make-blue star, o/l relay 415v ac lr1d-32-355 28-40a,tc

CTN :44608642 Due date: 25 May, 202625 May, 2026 NA
Tender For bid to ras bid to ras corrigendum : supply of fabrication of customized load carrier for portable electronic device

Private Sector

CTN :45256527 Due date: 25 May, 202625 May, 2026 NA
Tender For procurement of goods digital weight bridge platform , digital load cell (30 ton), electronic weighing unit (it indicator) junction box remote display ,printer ,ci weight ,stamping
 Loading, Please wait...

Connect us via What's Up