Web Analytics Made Easy - StatCounter

Round Pole Tenders

Get complete information related to latest Round Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Round Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Round Pole Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43021751 Due date: 22 Dec, 202522 Dec, 2025 49.00 Lacs
Tender For repair/ maint of diesel generator set electric siren, amf panel, street light pole, lt panel, lt cable, earthing, rewinding of pump and motor and other connected miscellaneous work at dm range and alg ziro under ge (af) tezpur

State Government

CTN :43001565 Due date: 30 Dec, 202530 Dec, 2025 4.97 Lacs
Tender For repair of ex cc road from in front of dav school l 90 b12 mtr and required of 4 nos new installation electric pole location in front of 1rubi poddar 2 somnath chowdhury 3 arkabhaduri 4 hema harijan ward no 04 within jiaganj azimganj municipalitylat

Central Government/Public Sector

CTN :42601149 Due date: 06 Dec, 202506 Dec, 2025 49.00 Lacs
Tender For corrigendum : repair maint replacement of lt electric installations, lt ug cable, corroded panels, pole painting and allied works at ss no. 3 ph no. 03, auditorium and zone b area of sevoke road mil stn under ge sevoke road

CTN :42933062 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For tender for supply of job order for urgent repair of transformer of cap 400 kva at mil stn kalka : : - disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

Central Government/Public Sector

CTN :42914318 Due date: 15 Dec, 202515 Dec, 2025 NA
Tender For tender to come for rate contract for electrical items as required for repair or replacement work at nagaon medical college, nagaon, assam - electrical items with specifications, 0.5 watt bulb, 1 kw automatic voltage stabilizer, 1.5 sqmm copper cable (3 core), 1.5 sqmm copper wire single core, 10 watt rechargeable led bulb, 10mm wire (red, yellow, blue, black) for ductable a/c, 16 amp socket, 16 amp socket (modular), 16 amp ss combine without box, 16 amp switch, 16 amp switch modular, 2 feet led tube, 2 pin holder, 2 pin top, 2.5 sqmm copper cable (3 core), 2.5 sqmm copper wire single core, 3 pin top (industrial), 3 pin top , 32 amp, 3 pin top , 6 amp, 4 core 2.5 sqmm copper wire, 4 sqmm copper cable (3 core), 4 sqmm copper wire single core, 4mm wire (red, yellow, blue, black) for ductable a/c, 6 amp 3 pin top, 6 amp socket, 6 amp ss combine, 6 amp switch, 6mm wire (red, yellow, blue, black) for ductable a/c, ac starter (modular) 16 amp, aluminium lug 195 sqmm, aluminium lug 250 sqmm, aluminum lug 120 mm, aluminum lug 150 mm, aluminum lug 16 mm, aluminum lug 195 sqmm, aluminum lug 25 mm, aluminum lug 35 mm, aluminum lug 400 sqmm, aluminum lug 50 mm, aluminum lug 70 mm, aluminum lug 95 mm, angle holder, armoured cable 195 sqmm, armoured cable 195 sqmm, armoured cable 250 sqmm, armoured cable 3.5 core, 150 sq, armoured cable 3.5 core, 170 sq, armoured cable 3.5 core, 35 sq, armoured cable 3.5 core, 50 sq, armoured cable 3.5 core, 70 sq, armoured cable 400 sqmm, autoclave connector, autoclave heating element 2 kw, batten holder, battery water, bed switch, blank plate 6amp, bolt (fasting nut) 3 inch, brass holder, btc cable 10 mm, btc cable 2.5 sqmm, btc cable 4mm, btc cable 6 mm, bulb 100 watt(incandescent), bulb 60 watt (incandescent), calling bell switch, capacitor for ac use 2.5 mfd, casing coping , casing coping 1.5 , casing coping 1 , casing coping 2 , ceiling fan (48 inch), ceiling fan (56 inch), change over switch 200amp (panel mounted), change over switch 200amp (reliable), change over switch 400amp (panel mounted), change over switch 400amp (reliable), change over switch 600amp (reliable), change over switch 630amp (panel mounted), chisel (1/2 ), chisel (1 ), comibation pliers, connector 10pin ac use, connector 12pin ac use, copper lug 120 mm, copper lug 150 mm, copper lug 16 mm, copper lug 25 mm, copper lug 35 mm, copper lug 50 mm, copper lug 70 mm, copper lug 95 mm, copper wire 1 sqmm, copper wire 1.5 sqmm, copper wire 10 sqmm, copper wire 2.5 sqmm, copper wire 4 sqmm, copper wire 6 sqmm, cut out 500 amp/ 200 amp, dp box (12 way), dp box (4 way), dp box (6 way), dp box (9 way), dp box 10 way, dp box 12 way, dp box 2 way, dp mcb 20 amp, dp mcb 32 amp, dp mcb 40 amp, dp mcb 63 amp, drill bit (13 mm), drill bit (3/16 mm), drill bit (6mm), earthing wire 1.5 sqmm, electric kettle (1.5 ltr) 1000 w, electronic tube choke, exhaust fan (12 inch), exhaust fan (15 inch), exhaust fan (18 inch), extension socket board spike protect, fan capacitor 2.5 mf, fan regulator electronics, fan regulator modular, flexible pipe, flexible wire (aluminum), flexible wire (copper), fuse wire 100 amp, fuse wire 200 amp, generator battery 12 volt 130 ah, generator battery 12 volt 150 ah, generator battery 12 volt 180 ah, generator battery 200 ah, generator battery 220 ah, geyser 15 ltr, geyser 25 ltr, halogen tube, 1000 watt, halogen tube, 500 watt, indusial socket with top 20 amp, mcb, indusial socket with top 32 amp, mcb, led bulb 12 watt, led bulb 18 watt, led bulb 20 watt, led bulb 23 watt, led bulb 3 watt, led bulb 30 watt, led bulb 40 watt, led bulb 9 watt, led halogen 100 watt, led halogen 200 watt, led street light 25 watt, led street light 40 watt, led street light 50 watt, led torch light (10 w), led torch light (20 w), led tube light 18 watt (t5), led tube light 28 watt (t5), line tester, locker (manual) 18x12 , loker (digital) 18x12 , mcb 10 amp (3 pole), mcb 20 amp (3 pole), mcb 25 inch (1 pole), mcb 32 amp (1 pole), mcb 32 amp (3 pole)

Central Government/Public Sector

CTN :42885315 Due date: 13 Dec, 202513 Dec, 2025 45.00 Lacs
Tender For repair / replacement / maint of electric rcc / steel pole, ug cable, painting of poles / panels, solar / flood / street lights and connected accessories at t line area micts, 299 area, shivaji enclave area and certain locations under ge kamptee

Central Government/Public Sector

CTN :42795682 Due date: 09 Dec, 202509 Dec, 2025 16.50 Lacs
Tender For special repair to road and road furniture from main gate (rp gate) to electric pole no. 170 and from building no. sl-77 to sl-89 at mil stn mount abu under age (i) udaipur