Get complete information related to latest Safety Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Safety Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Safety Device Tenders.
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as
Tender For corrigendum : providing of testing service for on-board /commissioned equipment/ instrument related to plant - as per bid document-hydraulic press machines and safetydevicesnt-; as per bid document; as per bid document
Tender For corrigendum : tender for supply of system description general requirements including cyber security technical requirements full hd fixed box type ip colour camera with varifocal lens and housing & mount 4k uhd fixed box type ip colour camera (type a/type b) with varifocal lens and housing & mount full hd bullet type ip colour camera 4k uhd bullet type ip colour camera (type a/type b) full hd fixed dome type ip colour camera full hd ptz (pan, tilt, zoom) ip colour camera digital keyboard large format display monitor server/workstation hardware network video recorder (nvr) pc workstation external storage device core switch (1). aggregation switch (ii). layer 2 switch (24 port) a. poe b. non-poe (iii) field switch a. b port b. 4 port wireless transmitter/receiver unit copper to fiber media convertor various types of cables software requirement video management software graphical user interface client software video recording software artificial intelligence (al) enabled video analytics software remote viewing on web and mobile app functional requirement of command control centre (ccc) software face recognition software software license test requirements test procedure quality assurance making and packing information to be supplied by the purchaser training documentation schematic diagram- 1: schematic diagram of ip based video surveillance system at stations schematic diagram 2: schematic diagram for video surveillance system for cluster of stations schematic diagram- 3: schematic diagram for cloud based architecture of video surveillance system for cluster of stations
Tender For providing of custom bid for services - check safetydevice including gear box earth connection of port and stbd gear box on pac basis firm m/s dynatron for icgs c-411
Tender For corrigendum : procurement of medical consumables items for use by the department of cardiac surgery, goa medical college - ported iv cannula 14g, ported iv cannula 16g, ported iv cannula 18g, ported iv cannula 20g, ported iv cannula 22g, non ported iv cannula without wings 21/4" 20g, non ported iv cannula without wings 21/4" 22g, non ported iv cannula without wings 2 24g, arterial cannula with switch 20g, ported i v cannula with safetydevice with self activating clip technology size - 16g, ported i v cannula with safetydevice with self activating clip technology size - 18 g, ported i v cannula with safetydevice with self activating clip technology size - 20 g, iv.macro sets with luer lock, blood transfusion set with 200m filter with luer lock, volumetric sets (non pvc) with luer lock (burrette set), pressure transducer kit (giving cco and predict hypotension ), 3-way stop cock (poly amide), 3-way stop cock with poly amide ext tube-10cms, nirs sensors compatable with hemosphere monitor adult, nirs sensors compatable with hemosphere monitor peadiatric, 3-way stop cock with poly amide ext tube-150cms, disposable syringes latex free size: 2 ml, disposable syringes latex free size: 5 ml, disposable syringes latex free size: 10 ml, pressure monitoring lines 200 cms male to female should have psi of equal to or greater than 500., pressure monitoring lines 200 cms male to male should have psi of equal to or greater than 500., disposable pressure transducers kits us fda approved, with interface cables ( compatible with philips and ge monitors ) atleast one cable to be provided free for every 25 transducers, single lumen 16g cvp catheter set in tray pack with needle with non kinkable guide wire appropriate dilator, introducer sheath to match sg/ cco/cedv/svo2/ref catheters, combi catheter (cco & svo2), triple lumen catheter 5 f 6 cms size 22,22,20 g with non kinkable guide wire with j tip, triple lumen catheter 7f 16 cms size 18, 16,16 heparin and antimicrobial coated with non kinkable guide wire with an appropriate dialator, transducer holders to hold 4 pressure transducers, endo-treacheal tube cuffed disposable 3.5, endotracheal tube plain 4.0 size microcuffed, endotracheal tube plain 4.0 size plain, endotracheal tube plain 4.5 size cuffed, endotracheal tube plain 4.5 size plain, endotracheal tube plain 5.0 size plain, endotracheal tube plain 5.5 size plain, endotracheal tube cuffed disposable 5.0 size, endo-treacheal tube cuffed disposable 5.5 size, endo-treacheal tube cuffed disposable 6.0, endo-treacheal tube cuffed disposable 6.5, endo-treacheal tube cuffed disposable 7.0, endotracheal tube cuffed disposable 7.5 size, endotracheal tube cuffed disposable 8.0 size, endotracheal tube cuffed disposable 8.5 size, bacterial filters machine end 22f/22m, heat moisture exchange bacterial and viral filters 22/15 hydrophobic only(pediatric), heat moisture exchange bacterial and viral filters 22/15 hydrophobic only (adult), dpt kits (10 nos of interface cable to be provided compatible with philips), anaesthesia masks reusable transparent 2 with air cushion, anaesthesia masks reusable transparent 3 with air cushion, anaesthesia masks reusable transparent 4 with air cushion, anaesthesia masks reusable transparent 5 with air cushion, oxygen therapy masks adult, oxygen therapy masks paediatric, ryles tube 8, ryles tube 10, ryles tube 12, ryles tube 14, ryles tube 16, rebreathing bags/reservoir bags 0.5 liters, rebreathing bags/reservoir bags 2.0 liters, incentive spirometer, bains ventilation circuit (disposable ) adult sizewith 2 litres bag, infant feeding tube size 5, rotem sigma complete cartriges for intem c, extem c, fibtem c, aptem c (rotem machine ), rotem sigma complete cartriges for intem c, extem c, fibtem c, heptem c (rotem machine ), breathing tube circuit adult compatible with the f & p 950 humidifer system. should be light weight with sprial heating inluded in tube wall and insulating layer to prevent condensation with in