Get complete information related to latest Salvage Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Salvage Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Salvage Pump Tenders.
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For corrigendum : tender for supply of 250th swp model no in200 320il impeller nut with helicoil , shaft , 125tph sw pump model no in 100 160il pump bearings , 150tph fire pump model no in125 260il gasket , 150tph fire pump model no in125 260il pump bearing , 150tph fire pump model n in125 260il keys , 250tph sea water pump mode no in200 320il pump casing , 250tph sea water pump mode no in200 320il pump bearing , mechanical seal , 250tph sea water pump mode no in200 320il mechanical seal , 125tph sw pump model no in100 160il mechanical seal , bh ls system smps 6eps 6ep1334 1ld00 psu100d 24v 12 5a , 310tph salvagepump ns150 26n power cable 10m , 10tph fw pump 4 3 8 pressure gauge 0 to 10 kg cm2 , 125tph sw pump model no in100 160il semiconductor fuse 125a , 150 sw pump in 125 260il semiconductor fuse 160a
Tender For annual rate contract for repair of hc pumps, booster motor shaft rotor and submersible motor shaft rotor and bushes, submersible pumps submersible pump v6 installed at various pumping station in jal shakti phe division akhnoor - 1. annual rate contract for repair of hc pumps installed at various pumping stations in jal shakti (phe) division akhnoor. a) ksb make, b) fnc make, c) mather platt make, d)rkb make. 2. annual rate contract for repair of booster motor shaft rotar & submersible motor shaft rotor and bushes installed at various pumping stations in jal shakti (phe) division akhnoor. 3. annual rate contract for repair of submersible pumps installed at various tube wells/dug wells in jal shakti (phe) division akhnoor. 4. repairing of submersible pump (v-6).
Tender For bid to ras corrigendum : statement of technical requirement for preperation of ietm document for ship system and integration of equipment ietm by ietm integrator. - main engine, gear box, stern gear system, diesel alternator with accessories, steering gear, fin stabilizer, ac plant, stp/vts, lo centrifuge, fo centrifuge, salvagepump, fire pump, bilge pump, ro plant, fresh water pump and hydrophore tank, ows, hp air cylinder, ref plant, high pressure air compressor (dd), high pressure air compressor (md), fo transfer pump (gear pumps), lo transfer pump (gear pumps), magazine fire fighting system, fm 200 fire fighting system, dirty oil pump, ba charging compressor with accessories, avcat pump, avcat filter water seperator & wbf, fuel oil stripping pump, diesel driven fire pump, emergency da, iccp & asg, afac, advanced composite communication system (accs), lan system, mbsre & intercom, msb, apms, nlcp, sicads, sirs, sp telephone, sdn, srgm, srcg, tacan, trigun, uwt, v/uhf comint df search receiver (nayan), xbt, ipms, window wiper, hvlas, hdcs, uass, hvac equipment, hangar door, asist/nghhts, store lift, anchor capstan
Tender For tender for supply of 250th swp model no in200 320il impeller nut with helicoil , shaft , 125tph sw pump model no in 100 160il pump bearings , 150tph fire pump model no in125 260il gasket , 150tph fire pump model no in125 260il pump bearing , 150tph fire pump model n in125 260il keys , 250tph sea water pump mode no in200 320il pump casing , 250tph sea water pump mode no in200 320il pump bearing , mechanical seal , 250tph sea water pump mode no in200 320il mechanical seal , 125tph sw pump model no in100 160il mechanical seal , bh ls system smps 6eps 6ep1334 1ld00 psu100d 24v 12 5a , 310tph salvagepump ns150 26n power cable 10m , 10tph fw pump 4 3 8 pressure gauge 0 to 10 kg cm2 , 125tph sw pump model no in100 160il semiconductor fuse 125a , 150 sw pump in 125 260il semiconductor fuse 160a