Get complete information related to latest Sample Collection Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sample Collection Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sample Collection Tenders.
Tender For complete contact spring set for sge d/l block instt.as per drg no. sge-25a, sge-26b (without base), sge-29a. material should be supplied as per is specification and chemical composition analysis testing certificate is required from govt. approved lab at the time of delivery of material. sample to be got approved before bulk supply. each set of spring should be packed in good quality plastic packet.(shop no.08) [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work contract of chemical lab dm plant cw plant coal feeder and coal sample room etc for work of coal rake coal bunker chp belt samplecollection an..
Tender For providing of custom bid for services - deployment of manpower for samplecollection and preparation room at siding no 1 and 2 at bhubaneswari ocp under bbsri area for a period of 120 days
Tender For supply, installation, testing, commissioning, reading, analysis and 1 year o&m of power quality meter complying to iec 61000-4-30 class a at tss in ljn division of n.e. railway.
Tender For providing of custom bid for services - job work for assistive services- animal handling and samplecollection support, pri clinical data record and compilation, laboratory equipments maintenance and calibration record keeping, large animal trial support and documentation, procurement support and documentation, experimental data analysis, media preparation and autoclavable, finance record maintenance, labware washing and sterilization, preparation and record keeping.
Tender For providing of custom bid for services - engaging of semi-skilled and unskilled contractual manpower for quality control, exploration and sampling work at core/sampling lab, hilltop, 11c mine — including collection of blast hole & truck samples from deposits 14, 11c, and 11b, processing of samples for physical testing, and preparation of samples for chemical analysis).
Tender For corrigendum : supply of disposable laboratory items - container for urine, sputum, stool samplecollection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of m
Tender For corrigendum : excavation of trial pit, soil samplecollection, transportation, cbr value and compaction(mdd/omc) test at singhori sh road diversion under bssa.