Get complete information related to latest Sample Cooler Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sample Cooler Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sample Cooler Tenders.
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : supply of various spares for swas system of boiler stage-i at wtps - evaporator phe ( plate type heat exchanger ) kaori model :95-20/ equivalent for water chiller of swas room of boiler stage-i & ii, samplecooler sc-4-12-ss with shell and coil., samplecooler sc-4-6-ss with shell and coil., samplecooler sc-6-12-ss with shell and coil., process pump for water chiller of swas room of boiler stage-i & ii, re-circulation pump for water chiller of swas room of boiler stage-i & ii, water cool condenser maxell 2tr for water chiller of swas room of boiler stage-i & ii, compressor -r22 -copeland make -model: cr30 k6m-tfm-111dm-(3 phase) for water chiller of swas room of boiler stage-i & ii, expansion valve danfoss tex-2 for water chiller of swas room of boiler stage-i & ii, accumulater drayall 3tr (3-6) for water chiller of swas room of boiler stage-i & ii
Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , samplecoolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For special repair to special repairet lights, water cooler, ro system & ei in toilet blocks and staff room at mamlatdar office keshod, ta - keshod, dist - junagadh.
Tender For corrigendum : supply of spares of abb make so2 and nox gas analyzer system (make- abb, model- el3020) installed in unit-1 to 5 of kstps, rvunl, kota - so2 measuring cell (part no-769143), no measuring cell(part no-769143), so2 detector(part no-769118), no detector(part no-769117), ceramic filter(0.3 micron), actuator ss316 body pneumatic single acting actuator, pressure sensor for el 3020 model, samplecooler-single coil, samplecooler-double coil
Tender For corrigendum : requirement of spares of abb make so2 / nox gas analyzer system (make: abb, model: el3020) installed in unit1 to 5 of kstps, rvunl, kota - so2 measuring cell (part no-769143), no measuring cell (part no-769143), so2 detector (part no-769118), no detector (part no-769117), ceramic filter(0.3 micron), actuator ss316 body, pneumatic single acting, actuator, pressure sensor for el 3020, model, samplecooler-single coil, samplecooler-double coil
Tender For bid to ras supply of stand mounted samplecooler sh steam , stand mounted samplecooler boiler water , stand mounted samplecooler saturated steam , stand mounted samplecooler boiler feed water to economizer inlet , stand mounted samplecoolersample a dhx12 , stand mounted samplecoolersample b dhx06 , stand mounted samplecoolersample c dhx18 , samplecooler bpsclturbinesc01
Tender For corrigendum : repair and maintenance of office room no 14 to17, water cooler room and car parking shed of ee/emd-7 at sarita vihar new delhi